and Welcome to the Quadra-Fire Family!
Hearth & Home Technologies welcomes you to our tradition of excellence! In choosing a
This commitment begins with our research of the market, including ‘Voice of the Customer’ contacts, ensuring we make products that will satisfy your needs. Our Research and Development facility then employs the world’s most advanced technology to achieve the optimum operation of our stoves, inserts and fi replaces. And yet we are
meticulously fabricated and gold and nickel surfaces are
We wish you and your family many years of enjoyment in the warmth and comfort of your hearth appliance. Thank you for choosing
SAMPLE OF SERIAL NUMBER / SAFETY LABEL
LOCATION: HANGING ON A CHAIN ON BACK OF APPLIANCE
|
|
|
|
|
|
|
|
|
| Serial No / Numéro du |
| |||
| Portland | MODEL | / MODÈLE: CASTILE GAS STOVE |
| 007 |
|
|
|
| |||||
|
|
|
| VENTED GAS FIREPLACE HEATER |
|
|
|
|
|
|
|
| ||
| US |
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
| NOT FOR USE WITH SOLID FUEL |
|
|
|
|
|
|
| 1445 North HIghway |
|
Report No. / Rapport Numéro | FOURNAISE AU GAZ AVEC VENTILATION |
|
|
|
|
| Colville, WA 99114 |
| ||||||
|
| NE PAS UTILISER AVEC LE COMBUSTIBLE SOLIDE |
|
|
|
|
| www.quadrafire.com |
| |||||
APPROVED | FOR CANADA AND USA TO: |
|
|
|
|
| APPROUVÉ POUR LE CANADA ET LES |
| ||||||
ANSI | ANSI |
| ||||||||||||
applicable sections of UL307b Gas Burning Heating Appliances for Manufactured | et les sections applicable de UL 307b Appareils de Chauffage Au Gaz pour |
| ||||||||||||
Homes and Recreational Vehicles, CAN/CGA | les Maisons Mobiles et les Véhicules Motorisés, CAN/CGA |
| ||||||||||||
for use at High Altitudes.” This appliance is manufactured for operation with | Fired Appliances for use at High Altitudes”. Cet appareil est manufacturé |
| ||||||||||||
Natural Gas. |
|
|
|
|
|
|
|
|
| pour l’opération avec le Gaz Naturel. Pour une conversion au gaz propane |
| |||
For conversion to propane Manufacturer’s Part | les pièces du Manufacturier |
| ||||||||||||
be used. This appliance may be installed in a bedroom or bedsitting room; in | Cet appareil peut être utilisé dans une chambre à coucher ou salle de séjour; |
| ||||||||||||
Canada remote thermostat installation is required. |
|
|
|
|
| au Canada, l’installation d’un thermostat à distance est exigée. |
| |||||||
FANTYPEVENTEDCIRCULATOR / VENTILATEURCIRCULATOIRE |
|
|
|
|
|
|
|
|
| |||||
Optional Blower Kit |
|
| Thermal Efficiency / Efficacité thermique* |
| ||||||||||
120Vac, 60Hz., 12 Amperes or less (ou moins) |
|
|
|
|
|
| 81.43% NG (blower on / avec ventilateur allumé) |
| ||||||
|
|
|
|
|
| 82.75% LP (blower on / avec ventilateur allumé) |
| |||||||
Routepowercordawayfromunit./Éloignez le fil électrique de l'appareil. Donotroute |
|
|
| * With Maximum horizontal length. / Avec longueur horizontale maximum. |
| |||||||||
powercordunderoroverstove./Ne pas faire passer le fil électrique au dessus ou en dessous de l'appareil. |
|
|
| |||||||||||
|
|
|
|
|
|
|
| |||||||
|
|
|
|
| For use with Natural Gas | For use with Propane |
| |||||||
|
|
|
|
| Usage Au Gaz Naturel | Usage Au Gaz Propane |
| |||||||
|
|
|
|
|
|
|
|
|
|
| ||||
Input Rate on “HI” (BTU/Hr) | 31,000 |
|
| 30,000 |
| Puissance Évaluée à “HI” (BTU/Hr) |
| |||||||
Input Rate on “LO” (BTU/Hr) | 22,000 |
|
| 23,000 |
| Puissance Évaluée à “LO” (BTU/Hr) |
| |||||||
Maximum Output (BTU/Hr)** | 20,943 |
|
| 21,519 |
| Puissance Maximum (BTU/Hr** |
| |||||||
Main Burner Orifice |
|
|
| .106 |
|
| .063 |
|
| Orifice du Brûleur Principal |
| |||
Minimum Inlet Pressure (Inches W.C.) | 4.5” |
|
| 11” | Pression Minimum de la Valve (pouces W.C.) |
| ||||||||
Maximum Inlet Pressure (Inches W.C.) | 7.0” |
|
| 14” | Pression Maximum de la Valve (pouces W.C.) |
| ||||||||
Manifold Pressure on “HI” (Inches W.C.) | 3.5” |
|
| 10” | Pression du Collecteur d’ Échappement à “HI” (pouces W.C.) |
| ||||||||
**Max Venting, Blower On |
|
|
|
|
|
| **Ventilation Maximum, Ventilateur Allumé |
|
This appliance equipped only for altitudes
Cet appareil est équipé pour les altitudes de
This appliance must be installed in accordance with local codes, if any (and Commonwealth of Massachusetts approved); if none, follow the National Fuel Gas Code. ANSI Z223.1 or Canadian Installation Codes,
Cet appareil doit être installé en accord avec les codes locaux,
MINIMUM CLEAR NCES TO COMBUSTIBLES / ESPACE MINIMUM AUX COMBUSTIBLES
Minimum clearances required from combustible construction for all appliance surfaces.
Espaces minimum exigés de la construction combustible aux surfaces de l’appareil.
|
| F |
|
|
|
| C |
|
|
| D |
| B | A | A |
|
|
| |
|
| E |
|
A |
| A | C |
A. | Side of stove top to side wall | Du côté du poêle au côté du mur | |
B. | Back of stove to back wall (air shield) | 1/4 in. (6mm) | Le contrôle arrière au mur arrière (écran) |
C. | Corner of stove top to side wall | 1 in. (24mm) | Du coin du dessus du poêle au mur de côté |
D. | Minimum Alcove Height | 54 in. (1372mm) | Hauteur minimum du plancher au plafond |
E. | Maximum Alcove Depth | 36 in. (914mm) | Profondeur maximum de l'alcove |
F. | Minimum Alcove Width | 40 in. (1016mm) | Largeur minimum de l'alcove |
HEARTH: A
CHEMINÉE: Un coussinet
Date of Manufacture / Date du Manufacturier
| 2008 2009 2010 Jan Feb Mar Apr May Jun | Jul | Aug Sep Oct | Nov Dec |
|
| DO NOT REMOVE THIS LABEL / NE PAS ENLEVER L’ÉTIQUETTE | Made in U.S.A. / Fait Aux |
| ||
|
|
Serial Number
Barcode
Model Name
Test Lab & Report No.
Manufactured Date