Quadra-Fire CASTILE-GAS-CSB, CASTILE-GAS-MBK, 7023-111E, CASTILE-GAS-PMH Alcove Applications

Page 9

D

 

v

E

 

L

B

 

v

A

G

R

H

M

N

P

Q

(See Note 2)

V

v

B

v

 

 

F v

v

B

 

v

A

U.S.

(3 FT)

I

M

 

v X

 

J or K

T

V

S

Electrical

S

V

 

Service

 

 

 

 

 

 

 

 

 

 

D*

V

 

V

= VENT TERMINAL

X = AIR SUPPLY INLET

A

= 12 inches ............. clearances above grade, veran-

 

 

(See Note 1)

da, porch, deck or balcony

B= 12 inches ............ clearances to window or door that may be opened, or to per- manently closed window. (Glass)

D*

= 18 inches

vertical clearance to unventilat-

 

 

ed soffit or to ventilated soffit lo-

 

 

cated above the terminal

 

*30 inches

for vinyl clad soffits and below

 

 

electrical service

F= 9 inches .............. clearance to outside corner

G= 6 inches ............... clearance to inside corner

H= 3 ft. (Canada) ...... not to be installed above a gas meter/regulatorassemblywithin 3 feet (90cm) horizontally from the center-line of the regulator

I= 3 ft. ....................... clearance to gas service regula- tor vent outlet

J= 9 inches (U.S.A.)

12 inches (Canada)clearance to non-mechanical air supply inlet to building or the combustion air inlet to any other appliance

**a vent shall not terminate directly above a sidewalk or paved driveway which is located between two single family dwellings and serves both dwellings.

***only permitted if veranda, porch, deck or balcony is fully open on a minimum of 2 sides beneath the floor, or meets Note 2.

NOTE 1: On private property where termination is less than 7 feet above a sidewalk, driveway, deck, porch, veranda or balcony, use of a listed cap is suggested. (See vents components pages.)

NOTE 2: Termination in an alcove space (spaces only open on one side and without an overhang) are permitted with the dimensions specified for vinyl or non-vinyl siding and soffits. 1. There must be at least 3 feet minimum between termination caps. 2. All mechanical air intakes within 10 feet of a termination cap must be a minimum of 3 feet below the termination cap. 3. All gravity air intakes within 3 feet of a termination cap must be a minimum of 1 foot below the termination cap.

NOTE 3: Location of the vent termination must not interfere with access to the electrical service.

Figure 4.4

= AREA WHERE TERMINAL IS NOT PERMITTED

K

=

3 ft. (U.S.A.)

 

 

 

6 ft. (Canada)

clearance to a mechanical

 

 

 

(powered) air supply inlet

L**

=

7 ft

clearance above paved

 

 

(See Note 1)

sidewalkor a paved driveway

 

 

 

located on public property

M*** =

18 inches

clearance under veranda ,

 

 

 

porch, deck, balcony or over-

 

 

 

hang

 

 

42 inches

vinyl

S

=

6 inches

clearance from sides of

 

 

(See Note 3)

electrical service

T

=

12 inches

clearance above electrical

 

 

(See Note 3)

service

Alcove Applications

N

=

6 inches

non-vinyl sidewalls

 

 

12 inches

vinyl sidewalls

P

=

8 ft.

 

 

 

 

 

 

 

QMIN

 

RMAX

 

1 cap

 

3 feet

 

2 x Q ACTUA L

 

2 caps

 

6 feet

 

1 x Q ACTUA L

 

3 caps

 

9 feet

 

2/3 x Q ACTUA L

 

4 caps

 

12 feet

 

1/2 x Q ACTUA L

QMIN = # termination caps x 3 RMAX = (2 / # termination caps) xQACTUAL

NOTE: Local codes or regulations may require different clearances.

NOTE: Termination caps may be hot. Consider their proximity to doors or other traffic areas.

WARNING: In the U.S.: Vent system termination is NOT permitted in screened porches. You must follow side wall, overhang and ground clearances as slated in the instructions.

In Canada: Vent system termination is NOT permitted in screened porches. Vent system termination is permitted in porch areas with two or more sides open. You must follow side wall, overhang and ground clearances as stated in the instructions.

Quadra-Fire assumes no responsibility for the improper perfor- mance of the appliance when the venting system does not meet

these requirements.

CAUTION: IF EXTERIOR WALLS ARE FINISHED WITH VINYL SIDING, IT IS SUGGESTED THAT A VINYL PRO- TECTOR KIT BE INSTALLED (part #VPK-DV).

July 29, 2008

Quadra-Fire · Castile Gas Stove · 7023-111E

Page 9

Image 9
Contents Do not Discard this Manual What to do if you smell gasDo Discardnot Hot glass will cause burnsWelcome to the Quadra-Fire Family Table of Contents 1Listing and Code Approvals Requirements for the Commonwealth of Massachusetts BELOW. Keep Clear of ALL ObstructionsManufacturer Requirements Tools will apply to every installation Design & Installation ConsiderationsGetting Started Inspect Appliance & ComponentsClearances Selecting Appliance LocationVent Termination Minimum Clearances 4Termination LocationsAlcove Applications Venting Components Vent InformationUse of Elbows Measuring StandardsExceptions for Horizontal Installations How to Use the Vent Graph Venting GuidelinesType B Straight Out Installation Type a Up and Out InstallationType C 45 Elbow in Corner Installation Horizontal Termination203mm Step Direct Vent Pipe Vertical TerminationStep Twist-lock the vent cap and seal Cathedral Ceiling Class a Metal Chimney Type a & B Co-Axial to Co-Linear Type C Up & Out InstallationExisting Masonry Chimney Type a Type BCut and bend flashing as needed to fit Sealant adhesive Retro Connector Fuel Conversions Gas InformationConverting to LP Gas Propane Natural GASScrews Rubber Gasket Identification Label F Valve Regulator ReplacementPressure Gas Pressures Gas ConnectionCheck for GAS Leaks Connecting to the Appliance Recommendation for WireStanding Pilot Ignition System Wiring Wire Size Max. LengthON/OFF Accessories Appliance SetupRemove Shipping Materials Top to Rear Vent ConversionLeg Leveling System Baf e Installation/AdjustmentPositioning the Logs Mineral WoolOpening Front Door 16 nut Snap disc through bracket Glass Door Assembly Blower InstallationBlower Shutter Adjustment Damper Adjustment For top or rear vent installationsOperating Instructions Before Lighting ApplianceControls Lighting Appliance For Your Safety Read Before LightingFrequently Asked Questions Initial Break-in ProcedureAfter Appliance is Lit Symptom Possible Cause Corrective Action TroubleshootingBe Placed in this Opening After servicing Maintaining and Servicing Your ApplianceNecessary. USE Caution When CLEANING/HANDLING Ceramic Burner Maintenance Tasks InspectReference Materials Appliance Dimension DiagramSL-D Series Vent Components Vent Components DiagramHHT SL-P Vent Components ListTermination Caps & Kits Castile GAS Nbr Description Service Parts List cont’d. Castile GASPart Description SKUAlphabetical Order RV-CG-MBK Accessories Warranty Policy Lifetime WarrantyCastile Gas Contact InformationDealer Telephone