R
VOYAGEUR Wood Insert
D. Blower Replacement
1.The grille on the blower access assembly is hinged. Swing the grille downward to expose the 2 screws.
Figure 23.1.
2.Remove the 2 screws from the blower access assembly and slide assembly away from the appliance.
3.Disconnect the wires from the blower.
4.Remove the 2 screws from the hold down bracket and pull the blower and bracket forward.
5.Remove the blower from the hold down bracket.
6.Remove the protection guards from each end of the blower.
7.
CAUTION
Shock Risk.
•Do NOT remove grounding prong from plug.
•Plug directly into properly grounded 3 prong receptacle.
•Route cord away from appliance.
•Do NOT route cord under or in front of appliance.
WARNING
Fire Risk.
Do NOT allow hot coals or embers to overfl ow ash lip
•May melt protective wire coating on fan power cord causing electrical short, fi re or injury
CAUTION! Unplug appliance from power source before replacing any components.
Placement Slot
Blower Access
Assembly
Grille hinges | Hold Down | |
downward | ||
Bracket | ||
|
|
| Remove Screws and | |
Remove Screws & |
| Remove Both | |
Pull Access Assembly | Remove Screws from Hold | Protection Guards at | |
away from Insert | Each End | ||
Down Bracket and Pull | |||
|
|
Forward
Figure 23.1
November 22, 2011 | Page 23 |