Quadra-Fire VOYAGEUR-MBK, VOYAGEUR-PMH owner manual Mobile Home Installation

Page 47

R

VOYAGEUR Wood Insert

10 Mobile Home Installation

1.An outside air inlet must be provided for combustion and must remain clear of leaves, debris, ice and/or snow. It must be unrestricted while unit is in use to prevent room air starvation which can cause smoke spillage and an inability to maintain a fi re. Smoke spillage can also set off smoke alarms.

2.Unit must be secured to the mobile home structure. Remove bolts from each side of insert and use plumbers tape to secure to structure (a washer may be required). Re-install bolts.

3.Unit must be grounded with #8 solid copper grounding wire or equivalent and terminated at each end with N.E.C. approved grounding device.

4.The factory-built fireplace must meet (UM)84-HUD requirements for outside combustion air supply to the fi replace fi re chamber and the chimney must be listed to UL103 HT or a listed UL-1777 full length six inch (152mm) diameter liner must be used. It must be equipped with a spark arrestor cap and the outside air must be installed on the insert.

5.Refer to page 30 of this manual for clearance to combustibles and fl oor protections requirements. All clearances must be followed precisely.

6.Use silicone to create an effective vapor barrier at the location were the chimney or other component penetrates to the exterior of the structure.

7.Follow the chimney and chimney connector manufacturer’s instructions when installing the fl ue system for use in a mobile home.

8.Burn wood only. Other types of fuels may generate poisonous gases (e.g., carbon monoxide).

9.If unit burns poorly while an exhaust blower is on in home, (i.e., range hood), increase combustion air.

10.Installation shall be in accordance with the Manufacturers Home & Safety Standard (HUD) CFR 3280, Part 24.

NOTICE:

Offsets from the vertical, not exceeding 45°, are allowed per Section 905(a) of the Uniform Mechanical Code (UMC).

Offsets greater than 45° are considered horizontal and are also allowed, providing the horizontal run does not exceed 75% of the vertical height of the vent.

Construction, clearance and termination must be in com- pliance with the UMC Table 9C. This installation must also comply with NFPA 211.

NOTICE: Top sections of chimney must be removable to allow maximum clearance of 13.5 feet (411cm) from ground level for transportation purposes.

Spark Arestor Cap

Storm CollaR

Roof Flashing

Joist Shield/Firestop

Double Wall

Connector Pipe

Figure 47.1

WARNING

Asphyxiation Risk.

NEVER INSTALL IN A SLEEPING ROOM. Consumes oxygen in the room.

WARNING

Fire Risk.

Asphyxiation Risk.

Do not draw outside combustion air from:

Wall, fl oor or ceiling cavity

Enclosed space such as an attic or garage

Close proximity to exhaust vents or chimneys. Fumes or odor may result

CAUTION

THE STRUCTURAL INTEGRITY OF THE MOBILE HOME FLOOR, WALL AND CEILING/ROOF MUST BE MAINTAINED Do NOT cut through:

Floor joist, wall, studs or ceiling trusses.

Any supporting material that would affect the structural integ- rity.

November 22, 2011

7063-173D

Page 47

Image 47
Contents Hot glass will cause burns Voyageur Wood InsertMfg Date Voyageur Wood InsertSerial Number Model NameTable of Contents Voyageur Wood Insert Warranty Policy Voyageur Wood Insert Mobile Home Approved Listing and Code ApprovalsAppliance Certifi cation BTU & Effi ciency Specifi cationsYour Wood Appliance Operating InstructionsSeasoned Wood Voyageur Wood Insert Fire SafetyOverfi ring Combustible/Non-combustible MaterialsFinal Stage Kindling or First Stage Voyageur Wood Insert Burning ProcessSecond Stage Start-Up Air Control Manual Timer Over-RideVoyageur Wood Insert Automatic Combustion Control ACC Air ControlsVoyageur Wood Insert Burn Rates and Operating Effi ciency Correct Baffl e and Blanket Positions Voyageur Wood Insert Correct Baffl e & Blanket PlacementFuel Reloading Instructions Voyageur Wood Insert Building a FireHardwood vs Softwood Moisture Voyageur Wood Insert Wood FuelBlower Operating Instructions Opacity Smoke Frequently Asked QuestionsVoyageur Wood Insert Clear Space Your specifi c model Voyageur Wood Insert Quick Start GuideDisposal of Ashes Maintenance and ServiceChimney and Chimney Connector Inspection/Cleaning Cleaning Plated SurfacesInspect Firebrick & Replacement Instructions Voyageur Wood Insert Glass CleaningMonthly Voyageur Wood Insert Quick Reference Maintenance GuideStart Fire Problems Possible Cause Solution Troubleshooting GuideWiring Diagram Service Parts ReplacementGlass Replacement Snap Disc Replacement ContdShock Risk Voyageur Wood Insert Blower ReplacementDoor Cross Voyageur Wood Insert Tube Channel Assembly Replacement Draft Design and Installation ConsiderationsGetting Started Voyageur Wood Insert Negative Pressure Chimney Termination Requirements Voyageur Wood Insert Locating Your Stove & ChimneyVoyageur Wood Insert Rule Pre-Burn Check List Voyageur Wood Insert Tools And Supplies NeededInspect Appliance and Components Appliance Dimensions Dimensions and ClearancesMaximum Mantel Depth 12 inch 305mm Ember Protection Only Thermal Protection RequiredVoyageur Wood Insert Calculating Alternate Floor Protection Larger Chimneys Chimney SystemsVenting Systems InspectionsVoyageur Wood Insert Masonry Chimney Cont’d Replaces without a permit will void the listing Voyageur Wood Insert Metal Heat Circulating MasonryPrefabricated Metal Chimney Factory-Built Sold Fuel Fireplace Voyageur Wood Insert Securing Chimney ComponentsAltering the Fireplace Chimney Height / Rise and Run Voyageur Wood Insert Ovalizing Round Stainless Steel LinersAppliance Set-up Outside Air Kit InstallationFlue Adapter Leveling LegsVoyageur Wood Insert Securing Appliance to Stove Pipe/Liner Standard Surround & Trim Kit InstallationVoyageur Wood Insert Standard Surround & Cast Trim Kit Voyageur Wood Insert All Cast Surround Kit Blower Cord Installation on Left SidePlacement Slot Blower Access Assembly White Wire Mobile Home Installation Cast Iron Wood Insert Voyageur#7 Baffl e Protection Channel RService Parts#10 Brick Assembly At Depot#14 Access Assembly Stocked at Depot #13 Door Assembly#18 Control Asembly Service PartsStocked This manual may be ordered from an authorized dealer Surrounds see diagrams on following27.6 #27 Surround AssembliesDate of Service Performed By Description of Service Voyageur Wood Insert Service And Maintenance LogVoyageur Wood Insert Service And Maintenance Log Cont’d Contact Information