VOYAGEUR Wood Insert
B. Clearances to Combustibles, United States and Canada (UL and ULC)
NOTE: All measurements are from the fuel loading door opening.
Maximum Mantel Depth - 12 inch (305mm)
MANTEL
IDEWALL |
| B | FASCIA OR TRIM |
|
|
| |
S |
| *C |
|
|
|
| |
| A | INSERT | ** |
|
| D | |
|
| FUEL DOOR |
|
|
| F | E |
|
|
|
HEARTH EXTENSION
*Maximum
Mantel |
29 in. (736mm) |
Minimum from Top |
of Fuel Loading |
Door Opening |
| A | B | C | D |
|
|
|
|
|
Masonry, Heat Circulating & | 20.5 in. | 29 in. | 22 in. | 10.5 in. |
(521mm) | (736mm) | (559mm) | (267mm) | |
|
|
|
|
|
|
|
| ||
| USA | CANADA | ||
HEARTH EXTENSION | E | F | E | F |
|
|
|
|
|
| 16 in. | 8 in. | 18 in. | |
|
|
| (457mm) | (318mm) |
|
|
|
|
|
|
| |||
EMBER PROTECTION | Required on all installations for USA and Canada | |||
|
|
|
|
|
NOTE: Keep Ashlip |
Clear of Ashes |
Figure 32.2
NOTE: Hearth Rug may be used in Suggested Area
WARNING
Fire Risk.
•Comply with all minimum clearances to combustibles as specifi ed.
•Failure to comply may cause house fi re.
NOTE: Clearances may only be reduced by means approved by the regulatory authority having juris- diction
Figure 32.1 - Mantel Clearance
Page 32 | November 22, 2011 |