D. Locating Your Stove & Chimney
Location of the appliance and chimney will affect perfor- mance. As shown in Figure 28.1 the chimney should:
•Install through the warm space enclosed by the build- ing envelope. This helps to produce more draft, espe- cially during lighting and die down of the fi re.
•Penetrate the highest part of the roof. This minimizes the affects of wind turbulence and down drafts.
•Consider the appliance location in order to avoid fl oor and ceiling attic joists and rafters.
•Locate termination cap away from trees, adjacent structures, uneven roof lines and other obstruc- tions.
Your local dealer is the expert in your geographic area and can usually make suggestions or discover solutions that will easily correct your fl ue problem.
Recommended Recommended
Location Location
Marginal
Location
Location
Not
Recommended
Location NOT
Recommended
Windward
Outside Termination Cap | Leeward |
Figure 28.1
E. Chimney Termination Requirements
Follow manufacturer’s instructions for clearance, securing
flashing and terminating the chimney.
•Must have an approved and Listed cap
•Must not be located where it will become plugged by snow or other material
•Must terminate at least 3 feet (91cm) above the roof and at least 2 feet (61cm) above any portion of the roof within 10 feet (305cm).
•Must be located away from trees or other structures
NOTICE:
•Chimney performance may vary.
•Trees, buildings, roof lines and wind conditions affect performance.
•Chimney height may need adjustment if smoking or overdraft occurs.
NOTICE: Locating the appliance in a basement or in a location of considerable air movement can cause intermittent smoke spillage from appliance. Do not locate appliance near
•Frequently open doors
•Central heat outlets or returns