Quadra-Fire 7046-137C warranty ACC Wood Insert, Serial Number

Page 2

2700-I ACC Wood Insert

R

and Welcome to the Quadra-Fire Family!

Hearth & Home Technologies welcomes you to our tradition of excellence! In choosing a Quadra-Fire appliance, you have our assurance of commitment to quality, durability, and performance.

This commitment begins with our research of the market, including ‘Voice of the Customer’ contacts, ensuring we make products that will satisfy your needs. Our Research and Development facility then employs the world’s most advanced technology to achieve the optimum operation

of our stoves, inserts and fireplaces. And yet we are old- fashioned when it comes to craftsmanship. Each unit is meticulously fabricated and gold and nickel surfaces are hand-finished for lasting beauty and enjoyment. Our pledge to quality is completed as each model undergoes a quality control inspection.

We wish you and your family many years of enjoyment in the warmth and comfort of your hearth appliance. Thank you for choosing Quadra-Fire.

NOTE: Clearances may only be reduced by means approved by the regulatory authority having jurisdiction

SAMPLE OF SERIAL NUMBER / SAFETY LABEL

LOCATION: UNDER INSERT RIGHT SIDE PANEL - SWIVEL OUT TO VIEW

 

 

 

 

HOT WHILE IN OPERATION DO NOT TOUCH, KEEP

 

 

 

 

CAUTION: CHILDREN AND CLOTHING AWAY.

 

 

 

 

CONTACT MAY CAUSE SKIN BURNS. KEEP FURNISHINGS AND OTHER

 

 

 

 

COMBUSTIBLE MATERIAL FAR AWAY FROM THE APPLIANCE. SEE

 

 

 

 

NAMEPLATE AND INSTRUCTIONS.

Serial No / Numéro De Série

Serial Number

 

 

 

 

R

Tested and

O-T L

Portland

Report:

 

007013

Listed by

Oregon USA #061-S-78-6.2

 

 

C

 

US

 

Model: 2700-I ACC

 

 

OMNI-Test Laboratories, Inc.

 

 

 

 

 

 

 

 

 

TESTED TO:

WOOD INSERT

 

 

 

UL 1482, ULC S628-93

 

 

LISTED ROOM HEATER, SOLID FUEL TYPE. "For Use with Solid Wood Fuel Only."

Model Name

Also for use in Mobile Home.

 

 

PREVENT HOUSE FIRES

 

 

 

Install and use only in accordance with manufacturer's installation, venting and operating instructions.

 

CONTACT YOUR LOCAL BUILDING OR FIRE OFFICIALS ABOUT RESTRICTIONS AND INSTALLATION INSPECTION

 

IN YOUR AREA

 

 

 

Refer to manufacturer's instructions and local codes for precautions required for passing chimney through a combustible

Test Lab & Report

 

 

 

 

Number

 

Maximum Mantel Depth - 10 inches (254mm)

Minimum Clearances To Combustible Material

 

 

Masonry, Heat Circulating & Zero Clearance

 

 

Mantel

 

Refer to Clearances on reverse side for Canada

 

 

 

 

USA ONLY

 

 

 

 

 

 

 

SideWall

B

Fascia or Trim

 

D

Sidewall to Stove

19-3/4 in.

 

 

 

Side Trim to Stove

13 in.

 

 

 

 

B

Mantel to Stove

21-1/2 in.

 

 

 

 

C

Top Trim to Stove

14 in.

 

A

C

 

 

Hearth Extension from Glass

 

 

 

D

 

18 in.

 

Insert

Floor height 0 in. to 3-1/2 in. below insert base

 

 

 

Floor height greater than 3-1/2 in. below insert base

16 in.

 

 

 

 

 

F

 

 

F

Hearth Extenson from Side of Insert

8 in.

 

 

 

 

No Thermal Floor Protection Required in USA

 

Hearth Extension

 

 

 

 

 

Ember Floor Protection Required on All Installations

 

 

 

 

 

Manufactured by:

DO NOT REMOVE THIS LABEL

Made in U.S.A.

1445 N. Highway, Colville, WA 99114

www.quadrafire.com

 

U.S. ENVIRONMENTAL PROTECTION AGENCY - Certified to comply with July 1990 particulate emission standards.

2010 2011 2012

Jan

Feb

Mar

Apr

May June July

Aug Sept

Oct. Nov.

Dec.

Mfg Date

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7046-153

 

Page

7046-137C

December 15, 2009

Image 2
Contents ACC Wood Insert Hot glass will cause burnsACC Wood Insert Serial NumberTable of Contents ACC Wood Insert Warranty Policy ACC Wood Insert Listing and Code Approvals BTU & Efficiency SpecificationsGlass Specifications Appliance CertificationOperating Instructions Your Wood ApplianceOverfiring ACC Wood Insert Fire SafetyCombustible/Non-combustible Materials Seasoned WoodSecond Stage ACC Wood Insert Burning ProcessKindling or First Stage Final StageAir Controls Manual Timer Over-RideACC Wood Insert Automatic Combustion Control ACC Start-Up Air ControlBurn Rates and Operating Efficiency Correct Baffle and Blanket Positions Incorrect Baffle and Blanket PositionsACC Wood Insert Building a Fire ACC Wood Insert Wood Fuel Do not USE Chemicals or Fluids to Start a FireBlower Operating Instructions Opacity Smoke Frequently Asked QuestionsACC Wood Insert Clear Space Cleaning Plated Surfaces Maintenance and ServiceChimney and Chimney Connector Inspection/Cleaning Disposal of AshesInspect Firebrick ACC Wood Insert Glass CleaningInspect Firebrick Cont’d Baffle & Blanket Placement Troubleshooting Guide Start Fire Problems Possible Cause SolutionService Parts Replacement Glass Replacement Snap Disc ReplacementACC Wood Insert Blower Replacement Shock RiskACC Wood Insert Door Handle Assembly Baffle & Ceramic Blanket RemovalACC Wood Insert Tube Channel Assembly Replacement Draft Design and Installation ConsiderationsGetting Started ACC Wood Insert Negative Pressure ACC Wood Insert Locating Your Stove & Chimney Chimney Termination RequirementsACC Wood Insert Rule Flat RoofPre-Use Check List ACC Wood Insert Tools And Supplies NeededInspect Appliance and Components Dimensions and Clearances Appliance DimensionsSideWall Full Reline Build On-Site Hearth Support AccessoryACC Wood Insert Zero Clearance Floor Protection RequiredACC Wood Insert Calculating Alternate Floor Protection Inspections Chimney SystemsVenting Systems Masonry ChimneyACC Wood Insert Masonry Chimney Cont’d 36.1 ACC Wood Insert Metal Heat Circulating MasonryPrefabricated Metal Chimney Altering the Fireplace ACC Wood Insert Prefabricated Metal Chimney Cont’dSecuring Chimney Components Chimney Height / Rise and Run ACC Wood Insert Zero-Clearance FireplaceOvalizing Round Stainless Steel Liners Option One Installation Instructions Outside Air Kit InstallationItems Needed for Installation not supplied Option Two Installation InstructionsLeveling Legs Flue AdapterSlide ACC Wood Insert Surround & Trim Kit Installation Cont’d Top Installation InstructionsACC Wood Insert Blower Cord Installation on Left Side InstructionsShears, Measuring Tape, Gloves ACC Wood Insert Zero Clearance Adjustable Trim SupportAdjustable from 2 inches to 10 inches Mobile Home Installation Reference Materials Exploded DrawingsFigure a ACC Wood Insert Service Parts & Accessories Important this is Dated Information HOW to OrderStocked At Depot Description Comments Part Number Fasteners StockedDescription Comments Part Number ACC Wood Insert Service And Maintenance Log Date of Service Performed By Description of ServiceContact Information