Material

Thermal Conductivity: k value

The k value indicates the amount of heat (in BTU’s) that will flow in 1 hour through 1 square foot of a uniform mate- rial 1 inch thick for each degree (F) of temperature differ- ence from one side of the material to the other.

The LOWER the k factor means less heat is being con- ducted through the non-combustible material to the com- bustible material beneath it.

The k value of a material must be equal or smaller then the required k value to be acceptable.

(BTU) (inch) (foot2 (hour) (oF)

Thermal Resistance: R value

The R value is a measure of a material’s resisteance to heat transfer.

R value is convenient when more than one material is used since you can add the R values together, where- as you can not do this for k value.

The HIGHER the R factor means less heat is being conducted through the non-combustible material to the combustible material beneath it.

The R value of a material must be equal or larger then the required R value to be acceptable.

Converting k to R:

Divide 1 by k and multiply the results times the thickness in inches of the material.

R = 1/k x inches of thickness

Converting R to k:

Divide the inches of thickness by R. k = inches of thickness/R

Calculatons:

Example: Floor protection requires k value of 0.84 and 3/4 inch thick.

Alternative material has a k value of 0.6 and is 3/4 inch thick.

Divide 0.6 by .75 = k value of 0.80. This k value is smaller than 0.84 and therefore is acceptable.

December 15, 2009

7046-137C

Page 33

Image 33
Contents Hot glass will cause burns ACC Wood InsertSerial Number ACC Wood InsertTable of Contents ACC Wood Insert Warranty Policy ACC Wood Insert Glass Specifications BTU & Efficiency SpecificationsListing and Code Approvals Appliance CertificationYour Wood Appliance Operating InstructionsCombustible/Non-combustible Materials ACC Wood Insert Fire SafetyOverfiring Seasoned WoodKindling or First Stage ACC Wood Insert Burning ProcessSecond Stage Final StageACC Wood Insert Automatic Combustion Control ACC Manual Timer Over-RideAir Controls Start-Up Air ControlBurn Rates and Operating Efficiency Incorrect Baffle and Blanket Positions Correct Baffle and Blanket PositionsACC Wood Insert Building a Fire Do not USE Chemicals or Fluids to Start a Fire ACC Wood Insert Wood FuelBlower Operating Instructions Frequently Asked Questions ACC Wood Insert Clear SpaceOpacity Smoke Chimney and Chimney Connector Inspection/Cleaning Maintenance and ServiceCleaning Plated Surfaces Disposal of AshesACC Wood Insert Glass Cleaning Inspect Firebrick Cont’dInspect Firebrick Baffle & Blanket Placement Start Fire Problems Possible Cause Solution Troubleshooting GuideGlass Replacement Snap Disc Replacement Service Parts ReplacementShock Risk ACC Wood Insert Blower ReplacementBaffle & Ceramic Blanket Removal ACC Wood Insert Door Handle AssemblyACC Wood Insert Tube Channel Assembly Replacement Design and Installation Considerations Getting StartedDraft ACC Wood Insert Negative Pressure Chimney Termination Requirements ACC Wood Insert Locating Your Stove & ChimneyFlat Roof ACC Wood Insert RuleACC Wood Insert Tools And Supplies Needed Inspect Appliance and ComponentsPre-Use Check List Appliance Dimensions Dimensions and ClearancesSideWall ACC Wood Insert Zero Clearance Floor Protection Build On-Site Hearth Support AccessoryFull Reline RequiredACC Wood Insert Calculating Alternate Floor Protection Venting Systems Chimney SystemsInspections Masonry ChimneyACC Wood Insert Masonry Chimney Cont’d ACC Wood Insert Metal Heat Circulating Masonry Prefabricated Metal Chimney36.1 ACC Wood Insert Prefabricated Metal Chimney Cont’d Securing Chimney ComponentsAltering the Fireplace ACC Wood Insert Zero-Clearance Fireplace Ovalizing Round Stainless Steel LinersChimney Height / Rise and Run Items Needed for Installation not supplied Outside Air Kit InstallationOption One Installation Instructions Option Two Installation InstructionsFlue Adapter Leveling LegsSlide Top Installation Instructions ACC Wood Insert Surround & Trim Kit Installation Cont’dInstructions ACC Wood Insert Blower Cord Installation on Left SideACC Wood Insert Zero Clearance Adjustable Trim Support Adjustable from 2 inches to 10 inchesShears, Measuring Tape, Gloves Mobile Home Installation Exploded Drawings Reference MaterialsFigure a Important this is Dated Information HOW to Order ACC Wood Insert Service Parts & AccessoriesStocked At Depot Description Comments Part Number Stocked Description Comments Part NumberFasteners Date of Service Performed By Description of Service ACC Wood Insert Service And Maintenance LogContact Information