Quadra-Fire 7046-137C ACC Wood Insert Door Handle Assembly, Baffle & Ceramic Blanket Removal

Page 23

R

2700-I ACC Wood Insert

D. Door Handle Assembly

1.Install washer on door handle shaft.

2.Slide door handle through door.

3.Install second washer(s) as shown in Figure 23.1.

4.Install key in groove.

5.Align groove in latch cam with key; slide latch cam over shaft

6.Install locknut but do not overtighten, the handle needs to move smoothly.

7.Install handle turning in a counter-clockwise motion to desired location on door handle rod. Figure 23.1.

E.Baffle & Ceramic Blanket Removal

1.Remove all ash from the firebox, and extinguish all hot embers before disposal into a metal container.

2.It is easier to remove both baffle boards and ceramic blanket after the tube channel assembly has been partially disassembled and the right side lowered. Follow steps 1 through 4 on page 24 for removal of the tube channel assembly. It is not necessary to completely remove the tube channel assembly.

3.Once the baffle protection cover has been removed, pull the baffle boards and ceramic blanket forward about 1 inch (25mm) and then overlap the baffles about 1-2 inches (25- 51mm). Figure 23.3.

4.Slide the tube channel assembly to the left as far as it will go and lower the right side. Remove the baffle boards and ceramic blanket together. Figure 23.4.

CAUTION! Do not overtighten lock nut. The door handle

4. Re-install in reverse order. Be sure the baffle boards and

needs to move smoothly.

ceramic blanket are in their proper positions. See Figure

 

12 .1 on page 12.

 

Door Cross Section

Latch Cam

(example)

Locknut

 

 

Spring

 

Handle

 

Door Handle

 

Spacing

 

Washers

 

Square Key

Figure 23.1 - Door Handle for Arched Door

Latch Cam

Door Cross

Section

Door Handle

Locknut

Spacing

Square Key

 

Washers

 

Fiber Handle

Figure 23.2 - Door Handle for Rectangular Door

Ceramic Blanket

Baffle Boards Overlapping

Figure 23.3

Slide Tube Channel to the

Left and Lower Right Side

Figure 23.4

December 15, 2009

7046-137C

Page 23

Image 23
Contents Hot glass will cause burns ACC Wood InsertSerial Number ACC Wood InsertTable of Contents ACC Wood Insert Warranty Policy ACC Wood Insert Appliance Certification BTU & Efficiency SpecificationsGlass Specifications Listing and Code ApprovalsYour Wood Appliance Operating InstructionsSeasoned Wood ACC Wood Insert Fire SafetyCombustible/Non-combustible Materials OverfiringFinal Stage ACC Wood Insert Burning ProcessKindling or First Stage Second StageStart-Up Air Control Manual Timer Over-RideACC Wood Insert Automatic Combustion Control ACC Air ControlsBurn Rates and Operating Efficiency Incorrect Baffle and Blanket Positions Correct Baffle and Blanket PositionsACC Wood Insert Building a Fire Do not USE Chemicals or Fluids to Start a Fire ACC Wood Insert Wood FuelBlower Operating Instructions Opacity Smoke Frequently Asked QuestionsACC Wood Insert Clear Space Disposal of Ashes Maintenance and ServiceChimney and Chimney Connector Inspection/Cleaning Cleaning Plated SurfacesInspect Firebrick ACC Wood Insert Glass CleaningInspect Firebrick Cont’d Baffle & Blanket Placement Start Fire Problems Possible Cause Solution Troubleshooting GuideGlass Replacement Snap Disc Replacement Service Parts ReplacementShock Risk ACC Wood Insert Blower ReplacementBaffle & Ceramic Blanket Removal ACC Wood Insert Door Handle AssemblyACC Wood Insert Tube Channel Assembly Replacement Draft Design and Installation ConsiderationsGetting Started ACC Wood Insert Negative Pressure Chimney Termination Requirements ACC Wood Insert Locating Your Stove & ChimneyFlat Roof ACC Wood Insert RulePre-Use Check List ACC Wood Insert Tools And Supplies NeededInspect Appliance and Components Appliance Dimensions Dimensions and ClearancesSideWall Required Build On-Site Hearth Support AccessoryACC Wood Insert Zero Clearance Floor Protection Full RelineACC Wood Insert Calculating Alternate Floor Protection Masonry Chimney Chimney SystemsVenting Systems InspectionsACC Wood Insert Masonry Chimney Cont’d 36.1 ACC Wood Insert Metal Heat Circulating MasonryPrefabricated Metal Chimney Altering the Fireplace ACC Wood Insert Prefabricated Metal Chimney Cont’dSecuring Chimney Components Chimney Height / Rise and Run ACC Wood Insert Zero-Clearance FireplaceOvalizing Round Stainless Steel Liners Option Two Installation Instructions Outside Air Kit InstallationItems Needed for Installation not supplied Option One Installation InstructionsFlue Adapter Leveling LegsSlide Top Installation Instructions ACC Wood Insert Surround & Trim Kit Installation Cont’dInstructions ACC Wood Insert Blower Cord Installation on Left SideShears, Measuring Tape, Gloves ACC Wood Insert Zero Clearance Adjustable Trim SupportAdjustable from 2 inches to 10 inches Mobile Home Installation Exploded Drawings Reference MaterialsFigure a Important this is Dated Information HOW to Order ACC Wood Insert Service Parts & AccessoriesStocked At Depot Description Comments Part Number Fasteners StockedDescription Comments Part Number Date of Service Performed By Description of Service ACC Wood Insert Service And Maintenance LogContact Information