Quadra-Fire 7046-137C warranty Service Parts Replacement, Glass Replacement Snap Disc Replacement

Page 21

 

R

2700-I ACC Wood Insert

 

 

5 Service Parts Replacement

 

A. Glass Replacement

B. Snap Disc Replacement

 

(Replace with 5mm ceramic glass only)

1. Locate the snap disc bracket assembly in the blower

1.

Ensure that the fire is out and the appliance is cool to

housing under the ash lip. Figure 21.1

 

the touch.

2. Using a 5/32 Allen wrench, remove the 4 mounting bolts

2.

Protect a table or counter top with padding or towels.

and slide assembly towards you.

 

Protect your hands and wear gloves to prevent injury.

3. Using a Phillips head screw driver, remove the 2 screws

3.

Remove the door with the broken glass by lifting the

from the snap disc and lift the snap disc off of the mounting

 

door up and off of the hinges.

bracket. Disconect the wires and replace with new snap

4.

Lay door face down on a table or counter making sure

disc and re-connect the wires. Figure 21.2.

 

the handle hangs over the edge so the door lays flat, on

4. Slide the blower housing back into position and secure with

 

a soft surface.

the 4 mounting bolts.

5.

Remove the screws from each glass retainer and remove

 

 

the glass. (If screws are difficult to remove, soak with

 

 

penetrating oil first).

 

6.

Center the glass with edges evenly overlapping the

 

 

opening in the door, (i.e. same space top and bottom,

 

 

left and right sides).

 

7.

Replace the glass retainers. Be careful not to cross

Snap Disc Location

 

thread the screws.

 

8.

Tighten each retainer just a few turns until each is

 

 

secured. Check again for centering of glass in door

 

 

frame. Continue to tighten each retainer alternately, a

 

 

few turns at a time, until the glass is secure. DO NOT

 

 

OVERTIGHTEN - can cause glass to break.

 

9.

Replace the door on the appliance.

 

WARNING! Risk of Fire or Injury!

Remove Bolts and Slide

Use only glass that is specified in the manual, DO NOT

Blower Assembly Out

replace with any other material. Glass breakage will occur.

 

CAUTION!

Handle glass with care.

Inspect the gasket to ensure it is undamaged.

Do NOT strike, slam or scratch glass.

Do NOT operate appliance with glass & door assembly removed.

Do NOT operate with glass cracked, broken or scratched.

Quadra-Fire appliances are equipped with ceramic super heat-resistant glass, which can only be broken by impact or misuse.

Figure 21.1 Snap Disc Location

Snap Disc

Figure 21.2

December 15, 2009

7046-137C

Page 21

Image 21
Contents Hot glass will cause burns ACC Wood InsertSerial Number ACC Wood InsertTable of Contents ACC Wood Insert Warranty Policy ACC Wood Insert Glass Specifications BTU & Efficiency SpecificationsListing and Code Approvals Appliance CertificationYour Wood Appliance Operating InstructionsCombustible/Non-combustible Materials ACC Wood Insert Fire SafetyOverfiring Seasoned WoodKindling or First Stage ACC Wood Insert Burning ProcessSecond Stage Final StageACC Wood Insert Automatic Combustion Control ACC Manual Timer Over-RideAir Controls Start-Up Air ControlBurn Rates and Operating Efficiency Incorrect Baffle and Blanket Positions Correct Baffle and Blanket PositionsACC Wood Insert Building a Fire Do not USE Chemicals or Fluids to Start a Fire ACC Wood Insert Wood FuelBlower Operating Instructions Frequently Asked Questions ACC Wood Insert Clear SpaceOpacity Smoke Chimney and Chimney Connector Inspection/Cleaning Maintenance and ServiceCleaning Plated Surfaces Disposal of Ashes ACC Wood Insert Glass Cleaning Inspect Firebrick Cont’d Inspect Firebrick Baffle & Blanket Placement Start Fire Problems Possible Cause Solution Troubleshooting GuideGlass Replacement Snap Disc Replacement Service Parts ReplacementShock Risk ACC Wood Insert Blower ReplacementBaffle & Ceramic Blanket Removal ACC Wood Insert Door Handle AssemblyACC Wood Insert Tube Channel Assembly Replacement Design and Installation Considerations Getting StartedDraft ACC Wood Insert Negative Pressure Chimney Termination Requirements ACC Wood Insert Locating Your Stove & ChimneyFlat Roof ACC Wood Insert RuleACC Wood Insert Tools And Supplies Needed Inspect Appliance and ComponentsPre-Use Check List Appliance Dimensions Dimensions and ClearancesSideWall ACC Wood Insert Zero Clearance Floor Protection Build On-Site Hearth Support AccessoryFull Reline RequiredACC Wood Insert Calculating Alternate Floor Protection Venting Systems Chimney SystemsInspections Masonry ChimneyACC Wood Insert Masonry Chimney Cont’d ACC Wood Insert Metal Heat Circulating Masonry Prefabricated Metal Chimney36.1 ACC Wood Insert Prefabricated Metal Chimney Cont’d Securing Chimney ComponentsAltering the Fireplace ACC Wood Insert Zero-Clearance Fireplace Ovalizing Round Stainless Steel LinersChimney Height / Rise and Run Items Needed for Installation not supplied Outside Air Kit InstallationOption One Installation Instructions Option Two Installation InstructionsFlue Adapter Leveling LegsSlide Top Installation Instructions ACC Wood Insert Surround & Trim Kit Installation Cont’dInstructions ACC Wood Insert Blower Cord Installation on Left SideACC Wood Insert Zero Clearance Adjustable Trim Support Adjustable from 2 inches to 10 inchesShears, Measuring Tape, Gloves Mobile Home Installation Exploded Drawings Reference MaterialsFigure a Important this is Dated Information HOW to Order ACC Wood Insert Service Parts & AccessoriesStocked At Depot Description Comments Part Number Stocked Description Comments Part NumberFasteners Date of Service Performed By Description of Service ACC Wood Insert Service And Maintenance LogContact Information