2700-I ACC Wood Insert

R

B. Optional Elbow Flue Adapter Installation

C. Securing Stove Pipe/Liner to Flue Collar

Optional use of a Simpson Duravent 15° Universal Elbow Part Number 4615 may be purchased directly through your local Simpson Durvent Pipe Distributor or from your local Quadra-Fire dealer, Part Number 15DEGADAPT.

Figure 40.1 shows a vertical installation and also how to create an optional 30° elbow installation.

The 15° elbow may be secured directly to the flue collar. Follow the pipe manufacturer’s instructions for using screws or rivets for attachment. Most pipe manufacturer’s 6 inch (152mm) diameter flue liners may be attached directly to the top of the 15° elbow.

1.There are 4 pre-drilled holes in the flue collar 90 degrees apart. Attach the flue collar to the stove pipe/liner. If the seal is questionable use stove mastic Figure 40.2.

2.Attach gasket to bottom side of flue collar with a thin coat of silicone.

A

 

 

Vertical

B

A

 

 

 

30o

30 degree

B

 

Gasket

Flue Collar

Stove Pipe/Liner

Figure 40.2

 

D.Leveling Legs

1.Remove the 2 screws already installed on each leg.

2.Move legs to the desired height.

3.Re-install the screws to secure in place.

Figure 40.1

 

 

 

 

 

Flue

A

B

Adapter

 

 

Vertical

13-9/16 in. (344mm)

20-15/16 in. (532mm)

30 Degree

14-5/8 in. (371mm)

20-11/16 in. (525mm)

Remove 2 screws from both sides. Adjust the legs up or down to level appliance.

Figure 40.3

Page 40

7046-137C

December 15, 2009

Image 40
Contents ACC Wood Insert Hot glass will cause burnsACC Wood Insert Serial NumberTable of Contents ACC Wood Insert Warranty Policy ACC Wood Insert BTU & Efficiency Specifications Glass SpecificationsListing and Code Approvals Appliance CertificationOperating Instructions Your Wood ApplianceACC Wood Insert Fire Safety Combustible/Non-combustible MaterialsOverfiring Seasoned WoodACC Wood Insert Burning Process Kindling or First StageSecond Stage Final StageManual Timer Over-Ride ACC Wood Insert Automatic Combustion Control ACCAir Controls Start-Up Air ControlBurn Rates and Operating Efficiency Correct Baffle and Blanket Positions Incorrect Baffle and Blanket PositionsACC Wood Insert Building a Fire ACC Wood Insert Wood Fuel Do not USE Chemicals or Fluids to Start a FireBlower Operating Instructions ACC Wood Insert Clear Space Frequently Asked QuestionsOpacity Smoke Maintenance and Service Chimney and Chimney Connector Inspection/CleaningCleaning Plated Surfaces Disposal of AshesInspect Firebrick Cont’d ACC Wood Insert Glass CleaningInspect Firebrick Baffle & Blanket Placement Troubleshooting Guide Start Fire Problems Possible Cause SolutionService Parts Replacement Glass Replacement Snap Disc ReplacementACC Wood Insert Blower Replacement Shock RiskACC Wood Insert Door Handle Assembly Baffle & Ceramic Blanket RemovalACC Wood Insert Tube Channel Assembly Replacement Getting Started Design and Installation ConsiderationsDraft ACC Wood Insert Negative Pressure ACC Wood Insert Locating Your Stove & Chimney Chimney Termination RequirementsACC Wood Insert Rule Flat RoofInspect Appliance and Components ACC Wood Insert Tools And Supplies NeededPre-Use Check List Dimensions and Clearances Appliance DimensionsSideWall Build On-Site Hearth Support Accessory ACC Wood Insert Zero Clearance Floor ProtectionFull Reline RequiredACC Wood Insert Calculating Alternate Floor Protection Chimney Systems Venting SystemsInspections Masonry ChimneyACC Wood Insert Masonry Chimney Cont’d Prefabricated Metal Chimney ACC Wood Insert Metal Heat Circulating Masonry36.1 Securing Chimney Components ACC Wood Insert Prefabricated Metal Chimney Cont’dAltering the Fireplace Ovalizing Round Stainless Steel Liners ACC Wood Insert Zero-Clearance FireplaceChimney Height / Rise and Run Outside Air Kit Installation Items Needed for Installation not suppliedOption One Installation Instructions Option Two Installation InstructionsLeveling Legs Flue AdapterSlide ACC Wood Insert Surround & Trim Kit Installation Cont’d Top Installation InstructionsACC Wood Insert Blower Cord Installation on Left Side InstructionsAdjustable from 2 inches to 10 inches ACC Wood Insert Zero Clearance Adjustable Trim SupportShears, Measuring Tape, Gloves Mobile Home Installation Reference Materials Exploded DrawingsFigure a ACC Wood Insert Service Parts & Accessories Important this is Dated Information HOW to OrderStocked At Depot Description Comments Part Number Description Comments Part Number StockedFasteners ACC Wood Insert Service And Maintenance Log Date of Service Performed By Description of ServiceContact Information