Napco Security Technologies GEM-P1664 installation instructions EZ Zone Doublingtm Configuration

Page 14
Page 14
BASIC ZONE CONFIGURATION
( – )

Wiring Connections: Basic Zone Configuration & EZ Zone Doubling Configuration

WI1424A 1/06

The basic zone configuration for the GEM-P1664 is 8 zones. Connect as shown above to terminals 13-24. Normally Closed (N.

C.) devices may be wired in series or Normally Open (N.O.)

devices may be wired in parallel. Use the 2.2K Ohm end-of-line (E.

O.L.) resistor in each zone, if selected in programming (refer to the

GEM-P1664 Programming Instructions). Zones 1-8 can be

selected for a “Fast Loop Response (50 ms)” or a “Normal Loop

Response (750 ms)”. Other zone options include Zone Type (Entry/

Exit, Interior, 24 Hour Protection, Trouble and Fire), Instant, Chime, Area Selection and PGM Output selection. Additional expansion

zone modules or wireless sensor transmitters/receivers can be used to obtain zones numbered 9 through 32.

EZ ZONE DOUBLINGTM CONFIGURATION

The control panel zone configuration may be expanded from 8 to 16

zones without the use of EZM Modules. To do so simply select “EZ

Zone Doubling” in programming (refer to the GEM-P1664

Programming Instructions) and connect zones as shown above.

NOTE: If both zones in a zone-pair configuration (ex: zones 1 & 9 in

the above diagrams) are to be used, then normally closed devices

must be wired to both zones. The 3.9K EOL resistor must be placed

at the end of the loop of the higher zone and the 2.2K EOL resistor

must be placed at the end of the loop of the lower zone.

If Normally open zones for fire or panic devices are required, then

the lower zone (2.2K EOL resistor) must be used and the higher zone (3.9K EOL resistor) must not be programmed for any area.

Additional expansion zone modules or wireless sensor transmitters/receivers can be used to obtain zones numbered 9 through 32

WARNING: Assigning a fire zone or keyswitch zones to a zone doubled will disable the respective complimentary zone. For example, if zone 8 is assigned as a fire zone, it will disable zone 16. If zone 3 is assigned as a fire zone, it will disable zone 11.

X GEM-P1664 Installation Instructions

LNAPCO Security Systems

Image 14
Contents Napco WI1424A 1/06 System Ready 09/01/05 1200 AMImportant Notice Changes from Previous EditionTable of Contents Introduction FeaturesGEM-P1664 Installation Instructions Lnapco Security Systems Page WI1424A 1/06Communicator Features WI1424A 1/06 5 Specifications GEM-P1664Ordering Information Optional Accessories and PeripheralsOrdering Information System ComponentsSummary of UL Requirements Smoke Detectors, 4-WireSmoke detectors & Summary of UL Requirements ResidentialControl Panel InstallationMounting GroundingWireless Systems WiringWiring Adding Expansion ZonesWI1424A 1/06 11  Testing the SystemSignal Strength Testing/Wireless Systems Auxiliary Power Wiring ConnectionsSIREN/BELL Power PGM OutputsEarth Ground Wiring Connections Remote Bus & Earth GroundRemote BUS WI1424A 1/06 13 EZ Zone Doublingtm Configuration Wire Smoke Detectors WI1424A 1/06 15 Wiring Connections Telephone Lines Telephone LinesConfiguring the Keypads Keypad Configuration ModeKeypad Installation ModeEZM Address Keypad Configuration ModeCompatibility Number Not Applicable Zone ResponseKeypad Address Keypad ConfigurationDisable Sounder Touchpad Back LightUser Codes & Zone Descriptions Basic OperationBasic Operation Arming and Disarming the System ArmingAuto Arming Not for UL Installations WI1424A 1/06 23  Alarm IndicationDisplay ZN Faults Bypassing ZonesDisplay ZN Bypassed Display Fire AlarmReset System Trbl Display ZN DirectoryActivate Program Enable Dealer ModeEnable User Mode Activate DownloadKeypad Messages Keypad MessagesGlossary AC Failure AC-Fail Report DelayGlossary WI1424A 1/06 27 Areas Zone Area 1-Zone Area 4 Priority Area Arming Alarm OutputsAmbush Keypad Ambush Ambush Codes Enable Global Ambush Battery Auto Status DisableBackup Report on Telco 1/Telco WI1424A 1/06 29 Cold Start Chime ZoneChirp Output on Keyfob Arm/Disarm Data FormatWI1424A 1/06 31  Date/TimeDisable Call Waiting Touch-tone Dialing Only Dial-Tone Detection Disable Auto Dial-Tone DetectionDigital Dialer Report Enter/Exit Test Mode Disable Call Waiting on 1st AttemptWI1424A 1/06 33  Enable Telephone Line Fault Test Enable CP-01 LimitsEnable TCP/IP Communications Exit/Entry FollowerWI1424A 1/06 35  KeyFob Control of Relay Groups 1 KeyFob Arm/Disarm chirp of Alarm OutputInterior Stay Bypass Keypad Area AssignmentsWI1424A 1/06 37  Memory Failure Power-Up DelayPre-Dial Delay Never Arm Do not use for primary Burglary protectionWI1424A 1/06 39  Relay Follows Zone Report Digital Dialer Exit Error/Recent ClosingSelect Alarm Output for Keyfob Chirp Report Telco 1 Report Telco 3 Double or Split ReportingWI1424A 1/06 41  Swinger Shutdown Tamper EZM Tamper Keypad Tamper RF Tamper Wireless TamperTemperature Display at Keypad Not evaluated by UL WI1424A 1/06 43  Trouble on Open Trouble on Short Not for UL installations Zone Status Wire, 4-Wire Smoke Detectors See Smoke Detectors Hour ZoneWI1424A 1/06 45  Standby STANDBY-BATTERY Calculation WorksheetBattery Calculation Worksheet Wiring Legend WI1424A 1/06 47 Function Mode Keypad Programming ModesKeypad Programming Modes Dealer Mode 49 Keypad Programming Modes Easy Menu Mode B456 123 DKeypad Programming Modes User Mode WI1424A 1/06 51 Keypad Configuration Mode Keypad Programming Modes Keypad Configuration ModeLocation WI1424A 1/06 53 Programming Address Is selected in the Easy Program Menu Out of Box Panel Operation GEM-P1664 Factory Default DescriptionWI1424A 1/06 55  Out of Box Panel Operation Prior to CP-01 Changes FCC Statement WI1424A 1/06 57 Page 59  GEM-P1664 Wiring DiagramGEM-P1664 Wiring Diagram Napco Limited Warranty

GEM-P1664 specifications

Napco Security Technologies has long been a leader in the security industry, recognized for its innovative solutions that enhance safety and monitoring capabilities. One of its standout products is the GEM-P1664, a versatile and robust control panel designed for both residential and commercial security applications. This advanced system combines user-friendly features with cutting-edge technology, making it an ideal choice for those looking to bolster their security measures.

The GEM-P1664 boasts a 16-zone configuration, allowing users to monitor multiple areas within a property simultaneously. Each zone can be independently programmed, providing flexibility in how security is managed. This feature is particularly valuable for larger facilities or homes with multiple entry points, as it ensures that all areas are adequately protected. The panel supports both hardwired and wireless zones, delivering versatility to suit various installation preferences.

One of the core technologies integrated into the GEM-P1664 is the use of Event Management and Reporting tools. The panel can automatically log security events, sending alerts via email or SMS in real-time. This capability is essential for maintaining awareness of security status, allowing users to respond promptly to any unauthorized access or unusual activity.

The user interface of the GEM-P1664 is designed with simplicity in mind. Its intuitive layout and navigation make it easy for both trained professionals and everyday users to operate the system without extensive technical knowledge. Additionally, the panel supports multiple user codes, allowing different levels of access for family members or staff, enhancing both security and convenience.

Another notable characteristic of the GEM-P1664 is its compatibility with various Napco peripherals and add-ons, including motion detectors, door/window sensors, and surveillance cameras. This interoperability enables users to create a comprehensive security ecosystem tailored to their specific needs. Furthermore, the GEM-P1664 is also compatible with mobile applications, allowing clients to monitor their security systems remotely via smartphones or tablets.

Lastly, the GEM-P1664 is built with future-proofing in mind. It is designed to be easily upgradable, ensuring that users can incorporate the latest technological advancements and security features as they become available. This forward-thinking approach ensures that the investment in the GEM-P1664 remains relevant and effective over time.

In summary, the Napco Security Technologies GEM-P1664 control panel is a powerful and flexible solution for anyone looking to enhance their security infrastructure. With its robust zone configuration, user-friendly interface, advanced reporting capabilities, and compatibility with a range of devices, the GEM-P1664 stands out as a top choice in the security technology landscape.