Napco Security Technologies GEM-P1664 installation instructions WI1424A 1/06 43 

Page 43

WI1424A 1/06

Page 43 

positive or negative temperature. If the temperature of 0 degrees is required, "negative zero" (-0) degrees must be used (+0 or an empty location is not a valid temperature). To simulate the sensor module, a power supply can be connected to Zone 6 and set from .55v to 3.05v to display the whole temperature range. Temperature values are read and updated every 5 seconds. To report an outer limit temperature, the temperature must be out of limits for 2 seconds. To avoid false alarm reports, the limits have a threshold of 5 degrees in the software. Two new logs have been created for temperature out of limits and restore. If the Gkey

is depressed and held down for 2 seconds, the date will display for 5 seconds.

Test Timer; Cancel Next Test Timer Report on Any Report

The test timer schedule is programmed via the Easy Program Menu and using Napco's Quickloader Software. If "Test Timer" is programmed, an automatic test report will be transmitted to the central station on the scheduled day(s) at the scheduled time. To report test timer, select Report Test Time to Telco 1 or 3 and program a report code. Program the Test Timer reporting time and day of the week. If "Cancel Next Test Timer Report on Any Report" is programmed, any report will cause the next test-timer transmission to be aborted, however subsequent test-timer transmissions will report as scheduled. Do not program this feature in UL installations.

Timeout

Specifies the length of time that an alarm, alert, or delay will remain active. See Time Selection.

Time Selection

The following times are programmable:

TIME(1)

UNITS

MAX. PROG. TIME

PGM2 OUTPUT TIMEOUT

MIN.

UNTIMED(2)

PGM2 OUTPUT ACCESS CONTROL TIME

SEC.

4 MIN., 15 SEC. (255 SEC.)

ALARM OUTPUT

MIN.

UNTIMED(1)(2)

PULSE-BURG OUTPUT

MIN.

UNTIMED(1)(2)

PGM1 OUTPUT

MIN.

UNTIMED(2)

ABORT DELAY

SEC.

4 MIN., 15 SEC. (255 SEC.)(3)

CHIME TIME

SEC.

63.25 SEC. (255 QTR-SEC.)(3)

AC-FAIL REPORT DELAY

10 MIN.

42 HR., 30 MIN. (2550 MIN.)

EXIT DELAY

SEC.

4 MIN., 15 SEC. (255 SEC.)(4)

ENTRY DELAY 1

SEC.

4 MIN., 15 SEC. (255 SEC.)(4)

ENTRY DELAY 2

SEC.

4 MIN., 15 SEC. (255 SEC.)(4)

SENSOR WATCH

HRS

254 HRS.

CANCEL WINDOW

MIN.

254 MIN.

ZONE INTEGRATION TIME

10 MILLISECONDS

2.55 SEC.

ZONE ANDING TIME

SEC.

255 SEC.

Time and Date (Keypad) in Dealer Program Mode

The Keypad Time and Date on the GEM-RP1CAe2/GEM-K1CA keypad may be set in Dealer Program Mode.

Time and Date (Keypad) in User Program Mode

When using an GEM-RP1CAe2/GEM-K1CA, the Time and Date may be set in the User Program Mode.

Time and Date Message Option

Glossary

In the event of a complete power failure (AC and DC) and the loss of the system clock, when the system is re-powered, a message 'SET TIME / DATE" will be displayed on the GEM-RP1CAe2 keypad. The message will remain until the Time and Date have been re-programmed.

Touch-tone Dialing Only; TouchTone Dialing with Rotary Backup

Select "TouchTone Dialing Only" if the subscriber has TouchTone service. TouchTone dialing is faster than rotary dialing, but not always as reliable.

For the communicator to use TouchTone on all dial attempts, program TouchTone Dialing Only. To use TouchTone on the first attempt with subsequent Rotary dial, program TouchTone Dialing with Rotary Backup. TouchTone Dialing Only will override TouchTone Dialing with Rotary Backup if both are selected. Note that if Backup Reporting is also selected, the communicator will alternate between TouchTone and rotary dial to reach Telephone 1, then Telephone 2. See Backup Report on Telco 2.

Trouble; Fire Trouble

An abnormal zone condition (a break in a normally-closed loop; a short on a normally-open loop; or either on an end-of-line-resistor supervised loop) when disarmed.

Trouble on a Burglary Zone is automatically displayed at the keypad unless Disable Zone Fault Scrolling is programmed. If a Burglary Zone is in trouble, it will go into alarm about 10 seconds after arming. However, if Auto Bypass is programmed, the keypad will beep upon arming (does not apply to selective- or group-bypassed zones).

LNAPCO Security Systems

X GEM-P1664 Installation Instructions

Image 43
Contents System Ready 09/01/05 1200 AM Napco WI1424A 1/06Changes from Previous Edition Important NoticeTable of Contents Page WI1424A 1/06 FeaturesGEM-P1664 Installation Instructions Lnapco Security Systems IntroductionWI1424A 1/06 5  Communicator FeaturesGEM-P1664 SpecificationsSystem Components Optional Accessories and PeripheralsOrdering Information Ordering InformationResidential Smoke Detectors, 4-WireSmoke detectors & Summary of UL Requirements Summary of UL RequirementsGrounding InstallationMounting Control PanelAdding Expansion Zones WiringWiring Wireless SystemsSignal Strength Testing/Wireless Systems Testing the SystemWI1424A 1/06 11  PGM Outputs Wiring ConnectionsSIREN/BELL Power Auxiliary PowerWI1424A 1/06 13  Wiring Connections Remote Bus & Earth GroundRemote BUS Earth GroundEZ Zone Doublingtm Configuration WI1424A 1/06 15  Wire Smoke DetectorsTelephone Lines Wiring Connections Telephone LinesMode Keypad Configuration ModeKeypad Installation Configuring the KeypadsZone Response Keypad Configuration ModeCompatibility Number Not Applicable EZM AddressTouchpad Back Light Keypad ConfigurationDisable Sounder Keypad AddressBasic Operation Basic OperationUser Codes & Zone Descriptions Arming Arming and Disarming the SystemAuto Arming Not for UL Installations Bypassing Zones Alarm IndicationDisplay ZN Faults WI1424A 1/06 23 Display ZN Directory Display Fire AlarmReset System Trbl Display ZN BypassedActivate Download Enable Dealer ModeEnable User Mode Activate ProgramKeypad Messages Keypad MessagesWI1424A 1/06 27  AC Failure AC-Fail Report DelayGlossary GlossaryAmbush Keypad Ambush Ambush Codes Enable Global Ambush Alarm OutputsAreas Zone Area 1-Zone Area 4 Priority Area Arming WI1424A 1/06 29  Auto Status DisableBackup Report on Telco 1/Telco BatteryData Format Chime ZoneChirp Output on Keyfob Arm/Disarm Cold StartDate/Time WI1424A 1/06 31 Disable Call Waiting on 1st Attempt Dial-Tone Detection Disable Auto Dial-Tone DetectionDigital Dialer Report Enter/Exit Test Mode Disable Call Waiting Touch-tone Dialing OnlyWI1424A 1/06 33  Exit/Entry Follower Enable CP-01 LimitsEnable TCP/IP Communications Enable Telephone Line Fault TestWI1424A 1/06 35  Keypad Area Assignments KeyFob Arm/Disarm chirp of Alarm OutputInterior Stay Bypass KeyFob Control of Relay Groups 1WI1424A 1/06 37  Never Arm Do not use for primary Burglary protection Power-Up DelayPre-Dial Delay Memory FailureWI1424A 1/06 39  Report Telco 1 Report Telco 3 Double or Split Reporting Report Digital Dialer Exit Error/Recent ClosingSelect Alarm Output for Keyfob Chirp Relay Follows ZoneWI1424A 1/06 41  Temperature Display at Keypad Not evaluated by UL Tamper EZM Tamper Keypad Tamper RF Tamper Wireless TamperSwinger Shutdown WI1424A 1/06 43  Trouble on Open Trouble on Short Not for UL installations WI1424A 1/06 45  Wire, 4-Wire Smoke Detectors See Smoke Detectors Hour ZoneZone Status Battery Calculation Worksheet STANDBY-BATTERY Calculation WorksheetStandby WI1424A 1/06 47  Wiring LegendKeypad Programming Modes Function Mode49  Keypad Programming Modes Dealer ModeB456 123 D Keypad Programming Modes Easy Menu ModeWI1424A 1/06 51  Keypad Programming Modes User ModeKeypad Programming Modes Keypad Configuration Mode Keypad Configuration ModeProgramming Address WI1424A 1/06 53 Location Is selected in the Easy Program Menu WI1424A 1/06 55  GEM-P1664 Factory Default DescriptionOut of Box Panel Operation Out of Box Panel Operation Prior to CP-01 Changes WI1424A 1/06 57  FCC StatementPage GEM-P1664 Wiring Diagram GEM-P1664 Wiring Diagram59  Napco Limited Warranty

GEM-P1664 specifications

Napco Security Technologies has long been a leader in the security industry, recognized for its innovative solutions that enhance safety and monitoring capabilities. One of its standout products is the GEM-P1664, a versatile and robust control panel designed for both residential and commercial security applications. This advanced system combines user-friendly features with cutting-edge technology, making it an ideal choice for those looking to bolster their security measures.

The GEM-P1664 boasts a 16-zone configuration, allowing users to monitor multiple areas within a property simultaneously. Each zone can be independently programmed, providing flexibility in how security is managed. This feature is particularly valuable for larger facilities or homes with multiple entry points, as it ensures that all areas are adequately protected. The panel supports both hardwired and wireless zones, delivering versatility to suit various installation preferences.

One of the core technologies integrated into the GEM-P1664 is the use of Event Management and Reporting tools. The panel can automatically log security events, sending alerts via email or SMS in real-time. This capability is essential for maintaining awareness of security status, allowing users to respond promptly to any unauthorized access or unusual activity.

The user interface of the GEM-P1664 is designed with simplicity in mind. Its intuitive layout and navigation make it easy for both trained professionals and everyday users to operate the system without extensive technical knowledge. Additionally, the panel supports multiple user codes, allowing different levels of access for family members or staff, enhancing both security and convenience.

Another notable characteristic of the GEM-P1664 is its compatibility with various Napco peripherals and add-ons, including motion detectors, door/window sensors, and surveillance cameras. This interoperability enables users to create a comprehensive security ecosystem tailored to their specific needs. Furthermore, the GEM-P1664 is also compatible with mobile applications, allowing clients to monitor their security systems remotely via smartphones or tablets.

Lastly, the GEM-P1664 is built with future-proofing in mind. It is designed to be easily upgradable, ensuring that users can incorporate the latest technological advancements and security features as they become available. This forward-thinking approach ensures that the investment in the GEM-P1664 remains relevant and effective over time.

In summary, the Napco Security Technologies GEM-P1664 control panel is a powerful and flexible solution for anyone looking to enhance their security infrastructure. With its robust zone configuration, user-friendly interface, advanced reporting capabilities, and compatibility with a range of devices, the GEM-P1664 stands out as a top choice in the security technology landscape.