Napco Security Technologies GEM-P1664 installation instructions WI1424A 1/06 33 

Page 33

WI1424A 1/06

Page 33 

security applications. When one or more zones is bypassed, the BYPASSED reminder on the GEM-RP1CAe2 keypad will display. Disable Code Required for Easy Bypass is enabled by default.

Disable Function-Mode Download See Callback-Method Download

Disable Openings/Closings

Provides the flexibility of disabling openings and/or closings for any area(s).

Disable Handshake on Xmit (All Formats)

Causes data transmission to wait one second after dialing a pager telephone number before sending data.

Disable PGM2 Clear on Disarm

PGM2 will not clear when a user code is entered to disarm.

Disable System Trouble Audible Timeout

If the trouble occurs when disarmed, the sounder will now automatically time out in 10 minutes, without the need to press [RESET].

(MUST be programmed in UL installations)

Disable Wait-for-Silence (Pager Format)

Causes data transmission to start immediately after the pager telephone number.

Disable Zone Fault Scrolling/Disable Auto Status

Non 24-Hour Zones that are open (or shorted) normally display "ZONE FAULTS" (while disarmed) followed by the zone number(s) and description(s). In high-security applications, program Disable Auto Status. Unsecured zones will then be indicated by a "ZONE FAULTED" display without zone numbers displayed. Status may be displayed manually using the DISPLAY STATUS function.

Double Reporting See Report Telco 3

"E" Lugs (E5, E15, E19) (Do not program for UL installations)

E5 - Lug E5 is used for Line Seizure. It is normally at 12V and when the telephone line is seized it goes to approximately 1V DC.

E15 - Lug E15 is used for Armed Status, either Armed Stay or Armed Away. When the system is armed it goes to approximately 1V DC. For multiple area systems: If only 1 area, Lug E15 goes active low when area 1 is armed; if 4 areas, areas 1 through area 4 have to be armed for Lug E15 to go active low.

Lug E15 Area 1 Armed Away Only: When enabled, Lug E15 will activate when area 1 is armed Away. Note: If this feature is not selected, the E15 Lug will, by default, activate when the system is armed (all areas).

E19 - Lug E19 is the Listen in Lug. It is an input and when it is forced low the panel will silence the keypad sounder and bell outputs so that the Veri-phone can listen to activity at the residence. See Veri-Phone (WI783): Silence All Outputs During Audio Session. Use Napco Part No. WL1 for field wiring.

Easy Exit (Not evaluated by UL)

While armed in the Interior Mode, Easy Exit can be initiated by pressing Dor U. Easy Exit restarts the Exit delay, allowing a User to exit an armed premises without disarming and rearming the system. Disable Dor Ubuttons as Easy Exit.

Easy Programming of Auto download ID #'s and PC Preset Callback # (GEM-RP1CAe2/GEM-K1CA only)

It is now possible to set the PC Preset Auto download ID # and PC Preset Callback phone number from the GEM-RP1CAe2/GEM- K1CA Easy Program Mode.

1.Enter Easy Program Mode and press PRIOR/NO until Central Phone # is displayed.

2.Program an "F" followed by the Auto Download ID # (2 digits) and then the Callback Telco # (up to 13 digits).

3.Press Uto save.

4.Exit Program Mode ([RESET] [RESET]).

5.Enter Function Mode

6.Go to Function "ACTIVATE DOWNLOAD Y/N" and press NEXT/YES.

7.The panel will automatically call the PCPreset computer and download the program on the specified Auto DL line #. Note: After the auto download of the control panel program, the system must be fully tested.

--See following example:

Glossary

LNAPCO Security Systems

X GEM-P1664 Installation Instructions

Image 33
Contents System Ready 09/01/05 1200 AM Napco WI1424A 1/06Changes from Previous Edition Important NoticeTable of Contents GEM-P1664 Installation Instructions Lnapco Security Systems FeaturesIntroduction Page WI1424A 1/06WI1424A 1/06 5  Communicator FeaturesGEM-P1664 SpecificationsOrdering Information Optional Accessories and PeripheralsOrdering Information System ComponentsSmoke detectors & Summary of UL Requirements Smoke Detectors, 4-WireSummary of UL Requirements ResidentialMounting InstallationControl Panel GroundingWiring WiringWireless Systems Adding Expansion ZonesTesting the System Signal Strength Testing/Wireless SystemsWI1424A 1/06 11  SIREN/BELL Power Wiring ConnectionsAuxiliary Power PGM OutputsRemote BUS Wiring Connections Remote Bus & Earth GroundEarth Ground WI1424A 1/06 13 EZ Zone Doublingtm Configuration WI1424A 1/06 15  Wire Smoke DetectorsTelephone Lines Wiring Connections Telephone LinesKeypad Installation Keypad Configuration ModeConfiguring the Keypads ModeCompatibility Number Not Applicable Keypad Configuration ModeEZM Address Zone ResponseDisable Sounder Keypad ConfigurationKeypad Address Touchpad Back LightBasic Operation Basic OperationUser Codes & Zone Descriptions Arming Arming and Disarming the SystemAuto Arming Not for UL Installations Display ZN Faults Alarm IndicationWI1424A 1/06 23  Bypassing ZonesReset System Trbl Display Fire AlarmDisplay ZN Bypassed Display ZN DirectoryEnable User Mode Enable Dealer ModeActivate Program Activate DownloadKeypad Messages Keypad MessagesGlossary AC Failure AC-Fail Report DelayGlossary WI1424A 1/06 27 Alarm Outputs Ambush Keypad Ambush Ambush Codes Enable Global AmbushAreas Zone Area 1-Zone Area 4 Priority Area Arming Backup Report on Telco 1/Telco Auto Status DisableBattery WI1424A 1/06 29 Chirp Output on Keyfob Arm/Disarm Chime ZoneCold Start Data FormatDate/Time WI1424A 1/06 31 Digital Dialer Report Enter/Exit Test Mode Dial-Tone Detection Disable Auto Dial-Tone DetectionDisable Call Waiting Touch-tone Dialing Only Disable Call Waiting on 1st AttemptWI1424A 1/06 33  Enable TCP/IP Communications Enable CP-01 LimitsEnable Telephone Line Fault Test Exit/Entry FollowerWI1424A 1/06 35  Interior Stay Bypass KeyFob Arm/Disarm chirp of Alarm OutputKeyFob Control of Relay Groups 1 Keypad Area AssignmentsWI1424A 1/06 37  Pre-Dial Delay Power-Up DelayMemory Failure Never Arm Do not use for primary Burglary protectionWI1424A 1/06 39  Select Alarm Output for Keyfob Chirp Report Digital Dialer Exit Error/Recent ClosingRelay Follows Zone Report Telco 1 Report Telco 3 Double or Split ReportingWI1424A 1/06 41  Tamper EZM Tamper Keypad Tamper RF Tamper Wireless Tamper Temperature Display at Keypad Not evaluated by ULSwinger Shutdown WI1424A 1/06 43  Trouble on Open Trouble on Short Not for UL installations Wire, 4-Wire Smoke Detectors See Smoke Detectors Hour Zone WI1424A 1/06 45 Zone Status STANDBY-BATTERY Calculation Worksheet Battery Calculation WorksheetStandby WI1424A 1/06 47  Wiring LegendKeypad Programming Modes Function Mode49  Keypad Programming Modes Dealer ModeB456 123 D Keypad Programming Modes Easy Menu ModeWI1424A 1/06 51  Keypad Programming Modes User ModeKeypad Programming Modes Keypad Configuration Mode Keypad Configuration ModeWI1424A 1/06 53  Programming AddressLocation Is selected in the Easy Program Menu GEM-P1664 Factory Default Description WI1424A 1/06 55 Out of Box Panel Operation Out of Box Panel Operation Prior to CP-01 Changes WI1424A 1/06 57  FCC StatementPage GEM-P1664 Wiring Diagram GEM-P1664 Wiring Diagram59  Napco Limited Warranty

GEM-P1664 specifications

Napco Security Technologies has long been a leader in the security industry, recognized for its innovative solutions that enhance safety and monitoring capabilities. One of its standout products is the GEM-P1664, a versatile and robust control panel designed for both residential and commercial security applications. This advanced system combines user-friendly features with cutting-edge technology, making it an ideal choice for those looking to bolster their security measures.

The GEM-P1664 boasts a 16-zone configuration, allowing users to monitor multiple areas within a property simultaneously. Each zone can be independently programmed, providing flexibility in how security is managed. This feature is particularly valuable for larger facilities or homes with multiple entry points, as it ensures that all areas are adequately protected. The panel supports both hardwired and wireless zones, delivering versatility to suit various installation preferences.

One of the core technologies integrated into the GEM-P1664 is the use of Event Management and Reporting tools. The panel can automatically log security events, sending alerts via email or SMS in real-time. This capability is essential for maintaining awareness of security status, allowing users to respond promptly to any unauthorized access or unusual activity.

The user interface of the GEM-P1664 is designed with simplicity in mind. Its intuitive layout and navigation make it easy for both trained professionals and everyday users to operate the system without extensive technical knowledge. Additionally, the panel supports multiple user codes, allowing different levels of access for family members or staff, enhancing both security and convenience.

Another notable characteristic of the GEM-P1664 is its compatibility with various Napco peripherals and add-ons, including motion detectors, door/window sensors, and surveillance cameras. This interoperability enables users to create a comprehensive security ecosystem tailored to their specific needs. Furthermore, the GEM-P1664 is also compatible with mobile applications, allowing clients to monitor their security systems remotely via smartphones or tablets.

Lastly, the GEM-P1664 is built with future-proofing in mind. It is designed to be easily upgradable, ensuring that users can incorporate the latest technological advancements and security features as they become available. This forward-thinking approach ensures that the investment in the GEM-P1664 remains relevant and effective over time.

In summary, the Napco Security Technologies GEM-P1664 control panel is a powerful and flexible solution for anyone looking to enhance their security infrastructure. With its robust zone configuration, user-friendly interface, advanced reporting capabilities, and compatibility with a range of devices, the GEM-P1664 stands out as a top choice in the security technology landscape.