Napco Security Technologies GEM-P1664 WI1424A 1/06 23 , Bypassing Zones, Unbypassing Zones

Page 23

WI1424A 1/06

Page 23 

Global Arm/Disarm

In a partitioned system, any of 4 secured areas may be armed (or disarmed) from the Manager's Mode (if en- abled). The Manager's Mode, is a low-security mode of operation. It provides quick access to other areas without having to go to another keypad of another area.

To arm all areas assigned to the user, press 9G[User Code] Uor D.

To disarm all areas assigned to the user, press 0G[User Code] Uor D.

BYPASSING ZONES

Selective Bypass (Bypassing Specific Zones)

A Selective Bypass will bypass a specific zone that has Selective Bypass enabled, by pressing the Bbutton followed by the zone number. The zone will be unbypassed the next time the system is disarmed. Note: Security Bypass is a option that requires a valid User Code to bypass zones. This feature is enabled at the factory and can be disabled using existing address (global "Enable Security Bypass"). In addition, when new User Codes are entered, the "User Area Option" must be enabled to allow the new User Code to bypass zones. See Programming Instructions (WI1422 or WI1423) for more information.

UNBYPASSING ZONES

(Unbypassing Specific Zones)

To unbypass a specific zone that has been bypassed, press the Bbutton followed by the zone number. The zone will be unbypassed the next time the system is armed.

ALARM INDICATION

If programmed to silence an alarm, enter a valid User Code and press the Ubutton.

The keypad must have permission to disarm the alarm (Alarm, Pulse Alarm, PGM1 or PGM2 outputs) from the specific area. This can be done through the PC Quickloader software, Area Features Screen or Area Bell Control. See Pro- gramming Instructions (WI1422 or WI1423) for specific address locations.

Should a burglary alarm occur, the red ARMED LED will flash, and the display will alternately read “ALARM”, then the zones violated. Disarm the panel; the display will read “ALARM” and will continue to indicate the violated zones until the Cbutton is pressed or the panel is armed once again.

FUNCTION MODE/DEALER PROGRAM MODE

The keypad can provide a wide assortment of utility functions as summarized in the Keypad Function Mode. The functions are displayed in a prompting “YES/NO” format. To skip a function, answer NO (press the PRIOR/NO button);

to select and execute a function, answer YES (press the Pbutton or the Ubutton). The complete function list is

provided here in its normal displayed sequence. However, since not all functions are designed for all systems (or intended for all users), only functions that are applicable and active are displayed. (For example, if no zones are bypassed, “DISPLAY ZN BYPASSED” will not appear). Furthermore, functions that are intended for use by the installer or servicer will not be displayed. Note: Functions may be manually scrolled forward or backward using the A(or

R) and Bbuttons, respectively.

To return to normal keypad operation, press the Cbutton. (The keypad will automatically return to its normal operating mode if no activity is detected for longer than one minute). Note: Due to space constraints, GEM-RP2ASe2/ GEM-K2AS message displays are abbreviated.

Remember: (1) Functions that are not active, not programmed and/or not applicable to the user's authority level will be suppressed and will not display. (2) Press the PRIOR/NO button to skip a function; press the NEXT/YES button to execute it. (3) The GEM-RP2ASe2/GEM-K2AS displays abbreviated messages that autoscroll.

DISPLAY ZN FAULTS

Press the YES button to identify all unsecured zones (within the keypad's area) while disarmed. Press NEXT but- ton to scroll through the zones. Manually bypassed zones will be indicated when displaying status.

Basic Operation

LNAPCO Security Systems

X GEM-P1664 Installation Instructions

Image 23
Contents System Ready 09/01/05 1200 AM Napco WI1424A 1/06Changes from Previous Edition Important NoticeTable of Contents Page WI1424A 1/06 FeaturesGEM-P1664 Installation Instructions Lnapco Security Systems IntroductionWI1424A 1/06 5  Communicator FeaturesGEM-P1664 SpecificationsSystem Components Optional Accessories and PeripheralsOrdering Information Ordering InformationResidential Smoke Detectors, 4-WireSmoke detectors & Summary of UL Requirements Summary of UL RequirementsGrounding InstallationMounting Control PanelAdding Expansion Zones WiringWiring Wireless SystemsWI1424A 1/06 11  Testing the SystemSignal Strength Testing/Wireless Systems PGM Outputs Wiring ConnectionsSIREN/BELL Power Auxiliary PowerWI1424A 1/06 13  Wiring Connections Remote Bus & Earth GroundRemote BUS Earth GroundEZ Zone Doublingtm Configuration WI1424A 1/06 15  Wire Smoke DetectorsTelephone Lines Wiring Connections Telephone LinesMode Keypad Configuration ModeKeypad Installation Configuring the KeypadsZone Response Keypad Configuration ModeCompatibility Number Not Applicable EZM AddressTouchpad Back Light Keypad ConfigurationDisable Sounder Keypad AddressUser Codes & Zone Descriptions Basic OperationBasic Operation Arming Arming and Disarming the SystemAuto Arming Not for UL Installations Bypassing Zones Alarm IndicationDisplay ZN Faults WI1424A 1/06 23 Display ZN Directory Display Fire AlarmReset System Trbl Display ZN BypassedActivate Download Enable Dealer ModeEnable User Mode Activate ProgramKeypad Messages Keypad MessagesWI1424A 1/06 27  AC Failure AC-Fail Report DelayGlossary GlossaryAreas Zone Area 1-Zone Area 4 Priority Area Arming Alarm OutputsAmbush Keypad Ambush Ambush Codes Enable Global Ambush WI1424A 1/06 29  Auto Status DisableBackup Report on Telco 1/Telco BatteryData Format Chime ZoneChirp Output on Keyfob Arm/Disarm Cold StartDate/Time WI1424A 1/06 31 Disable Call Waiting on 1st Attempt Dial-Tone Detection Disable Auto Dial-Tone DetectionDigital Dialer Report Enter/Exit Test Mode Disable Call Waiting Touch-tone Dialing OnlyWI1424A 1/06 33  Exit/Entry Follower Enable CP-01 LimitsEnable TCP/IP Communications Enable Telephone Line Fault TestWI1424A 1/06 35  Keypad Area Assignments KeyFob Arm/Disarm chirp of Alarm OutputInterior Stay Bypass KeyFob Control of Relay Groups 1WI1424A 1/06 37  Never Arm Do not use for primary Burglary protection Power-Up DelayPre-Dial Delay Memory FailureWI1424A 1/06 39  Report Telco 1 Report Telco 3 Double or Split Reporting Report Digital Dialer Exit Error/Recent ClosingSelect Alarm Output for Keyfob Chirp Relay Follows ZoneWI1424A 1/06 41  Swinger Shutdown Tamper EZM Tamper Keypad Tamper RF Tamper Wireless TamperTemperature Display at Keypad Not evaluated by UL WI1424A 1/06 43  Trouble on Open Trouble on Short Not for UL installations Zone Status Wire, 4-Wire Smoke Detectors See Smoke Detectors Hour ZoneWI1424A 1/06 45  Standby STANDBY-BATTERY Calculation WorksheetBattery Calculation Worksheet WI1424A 1/06 47  Wiring LegendKeypad Programming Modes Function Mode49  Keypad Programming Modes Dealer ModeB456 123 D Keypad Programming Modes Easy Menu ModeWI1424A 1/06 51  Keypad Programming Modes User ModeKeypad Programming Modes Keypad Configuration Mode Keypad Configuration ModeLocation WI1424A 1/06 53 Programming Address Is selected in the Easy Program Menu Out of Box Panel Operation GEM-P1664 Factory Default DescriptionWI1424A 1/06 55  Out of Box Panel Operation Prior to CP-01 Changes WI1424A 1/06 57  FCC StatementPage 59  GEM-P1664 Wiring DiagramGEM-P1664 Wiring Diagram Napco Limited Warranty

GEM-P1664 specifications

Napco Security Technologies has long been a leader in the security industry, recognized for its innovative solutions that enhance safety and monitoring capabilities. One of its standout products is the GEM-P1664, a versatile and robust control panel designed for both residential and commercial security applications. This advanced system combines user-friendly features with cutting-edge technology, making it an ideal choice for those looking to bolster their security measures.

The GEM-P1664 boasts a 16-zone configuration, allowing users to monitor multiple areas within a property simultaneously. Each zone can be independently programmed, providing flexibility in how security is managed. This feature is particularly valuable for larger facilities or homes with multiple entry points, as it ensures that all areas are adequately protected. The panel supports both hardwired and wireless zones, delivering versatility to suit various installation preferences.

One of the core technologies integrated into the GEM-P1664 is the use of Event Management and Reporting tools. The panel can automatically log security events, sending alerts via email or SMS in real-time. This capability is essential for maintaining awareness of security status, allowing users to respond promptly to any unauthorized access or unusual activity.

The user interface of the GEM-P1664 is designed with simplicity in mind. Its intuitive layout and navigation make it easy for both trained professionals and everyday users to operate the system without extensive technical knowledge. Additionally, the panel supports multiple user codes, allowing different levels of access for family members or staff, enhancing both security and convenience.

Another notable characteristic of the GEM-P1664 is its compatibility with various Napco peripherals and add-ons, including motion detectors, door/window sensors, and surveillance cameras. This interoperability enables users to create a comprehensive security ecosystem tailored to their specific needs. Furthermore, the GEM-P1664 is also compatible with mobile applications, allowing clients to monitor their security systems remotely via smartphones or tablets.

Lastly, the GEM-P1664 is built with future-proofing in mind. It is designed to be easily upgradable, ensuring that users can incorporate the latest technological advancements and security features as they become available. This forward-thinking approach ensures that the investment in the GEM-P1664 remains relevant and effective over time.

In summary, the Napco Security Technologies GEM-P1664 control panel is a powerful and flexible solution for anyone looking to enhance their security infrastructure. With its robust zone configuration, user-friendly interface, advanced reporting capabilities, and compatibility with a range of devices, the GEM-P1664 stands out as a top choice in the security technology landscape.