Inhibit System Trouble Audible at Keypad (Do not program in UL installations)

 

For installations where an audible during a system trouble is not desired, an option, Inhibit System Trouble Audible can be enabled.

 

Regardless of the system status (Armed or Disarmed) there is no keypad sounder in the event of a system trouble. However, the

 

trouble will still scroll in the keypad display until [RESET] is pressed and the SYS TBL icon will display until the trouble is restored.

 

To disable System Trouble Audible, enable the option Disable System Trouble Audible in the QL-Windows Keypad Features

 

screen.

 

Interior Stay Zones; Interior Normally Bypassed (Stay Mode); Auto Interior Bypass (Stay)/Easy Exit

 

Removal of a programmed group of interior (Stay) zones from the system will permit freedom of movement throughout the premises

 

but still allow protection from intrusion through armed perimeter zones. Pressing Eprior to arming will select the Interior Zones,

 

then arm to bypass. The next time the control panel is disarmed, all bypassed zones will automatically revert to non-bypassed

 

(disarmed) zones. When Eis pressed, the "BYPASS" reminder will come on.

 

The bypassed zones may be displayed on the keypad (see GEM-RP1CAe2 FUNCTION MODE).

 

If Interior Normally Bypassed is selected, all Interior (Stay) zones will always be inactive. The "BYPASS" reminder will always display,

 

indicating that only partial protection will be provided upon arming. To temporarily restore interior protection, press E; the

 

"BYPASS" reminder will go out upon arming, denoting full protection, however Interior (Stay) Zones will once again be bypassed the

 

next time the panel is disarmed.

 

If "Auto Interior Bypass/Easy Exit" is programmed, all Interior Zones will automatically be bypassed if the Exit/Entry doors are not

 

opened during exit delay. If Dis pressed while armed with Interior Bypassed (Stay), exit delay will restart and Exit/Entry doors may

 

be opened to permit someone to exit (while others remain on premises) without causing an alarm.

 

Interior (STAY) Bypass

 

Interior Zones, when bypassed, allow free movement within the home while the protection of armed perimeter zones is maintained.

 

To bypass Interior Zones, enter your User Code and press P. All zones (including Interior Bypass Zones) are all protected with

 

full protection, in ARMED AWAY mode.

Glossary

Jumpers (Refer to Wiring Diagram for UL configuration)

JP1: Keypad Configuration Jumper (top center) is installed across top and center pins for normal operation. When configuring GEM-

 

 

RP1CAe2 and GEM-K1CA keypads, move jumper across center and lower pins.

 

JP3: 2-Wire Fire jumpers. Select Zones 7 and/or 8 for use as either 2-Wire Fire Zones or Burglary Zones.

 

KeyFob Control of Relay Groups 1 and 2

 

The GEM-P1664 supports KeyFob Control of Relay groups 1 and 2. The KeyFob Aux 1 and Aux 2 buttons can be programmed to

 

toggle on and off external Relay Groups 1 and 2.

 

KeyFob Arm/Disarm chirp of Alarm Output.

 

The Key Fob Arm/Disarm chirp can be directed to the Alarm Output, which can free up the PGM2 Output for other uses such as

 

garage door opener control. To enable the Key Fob Arm/Disarm chirp option on Alarm Output, enable 'Chirp' Output on KeyFob Arm/

 

Disarm and Select Alarm Output for KeyFob 'Chirp' in the PCD-Windows Options screen.

 

Keyfob Transmitters; Chirp Output on Keyfob; Select Alarm for Keyfob Chirp

 

Keyfob transmitters can (1) operate up to four zones, or (2) can Arm/Disarm an area and provide two Auxiliary control buttons, but

 

cannot be operated in these two modes simultaneously. A Keyfob Transmitter set up to Arm/Disarm an area with "PGM2 Chirp on

 

Keyfob Arm/Disarm" will cause a 1chirp sound on arming and a 2 chirp sound on disarming, by using an steady state Alarm Output

 

(not a Pulse Alarm, Cadence Pulse Alarm or Voice Siren Driver). Programming the Auxiliary Keyfob Buttons to "C: PGM2 Output

 

Toggle" on Auxiliary 1 or 2 buttons will cause PGM2 to toggle the current condition of the PGM2 output. Keyfob 1-8 can have their

 

opening / closings reported as users 57 through 64, respectively.

 

Keypad Area Assignments

 

In multiple-area systems, each keypad must be individually configured to the correct keypad number. No two keypads can possess

 

the same keypad number. No keypad numbers can be skipped (they must be contiguous). Note that each address comprises 2

 

nibbles; enter the Area Number in the right nibble.

 

Keypad Digital Dialer Test

 

A Digital Dialer Test (Central Station Comm. Test) can be initiated from the function menu. Press Runtil "DIGITAL DIALER

 

TEST Y/N" is displayed and then press [NEXT/YES] to initiate the transmission of a Test Timer signal. Note: Test Timer reporting

 

codes and Report Test Timer on Telco1 or Telco 3 must be programmed.

 

Keypad Jumpers (GEM-RP1CAe2 / GEM-K1CA)

 

Refer to label LA1374 on the circuit board fishpaper for jumper locations and a summary of settings.

X GEM-P1664 Installation Instructions

LNAPCO Security Systems

Image 36
Contents Napco WI1424A 1/06 System Ready 09/01/05 1200 AMImportant Notice Changes from Previous EditionTable of Contents Features GEM-P1664 Installation Instructions Lnapco Security SystemsIntroduction Page WI1424A 1/06Communicator Features WI1424A 1/06 5 Specifications GEM-P1664Optional Accessories and Peripherals Ordering InformationOrdering Information System ComponentsSmoke Detectors, 4-Wire Smoke detectors & Summary of UL RequirementsSummary of UL Requirements ResidentialInstallation MountingControl Panel GroundingWiring WiringWireless Systems Adding Expansion ZonesTesting the System Signal Strength Testing/Wireless SystemsWI1424A 1/06 11  Wiring Connections SIREN/BELL PowerAuxiliary Power PGM OutputsWiring Connections Remote Bus & Earth Ground Remote BUSEarth Ground WI1424A 1/06 13 EZ Zone Doublingtm Configuration Wire Smoke Detectors WI1424A 1/06 15 Wiring Connections Telephone Lines Telephone LinesKeypad Configuration Mode Keypad InstallationConfiguring the Keypads ModeKeypad Configuration Mode Compatibility Number Not ApplicableEZM Address Zone ResponseKeypad Configuration Disable SounderKeypad Address Touchpad Back LightBasic Operation Basic OperationUser Codes & Zone Descriptions Arming and Disarming the System ArmingAuto Arming Not for UL Installations Alarm Indication Display ZN FaultsWI1424A 1/06 23  Bypassing ZonesDisplay Fire Alarm Reset System TrblDisplay ZN Bypassed Display ZN DirectoryEnable Dealer Mode Enable User ModeActivate Program Activate DownloadKeypad Messages Keypad MessagesAC Failure AC-Fail Report Delay GlossaryGlossary WI1424A 1/06 27 Alarm Outputs Ambush Keypad Ambush Ambush Codes Enable Global AmbushAreas Zone Area 1-Zone Area 4 Priority Area Arming Auto Status Disable Backup Report on Telco 1/TelcoBattery WI1424A 1/06 29 Chime Zone Chirp Output on Keyfob Arm/DisarmCold Start Data FormatWI1424A 1/06 31  Date/TimeDial-Tone Detection Disable Auto Dial-Tone Detection Digital Dialer Report Enter/Exit Test ModeDisable Call Waiting Touch-tone Dialing Only Disable Call Waiting on 1st AttemptWI1424A 1/06 33  Enable CP-01 Limits Enable TCP/IP CommunicationsEnable Telephone Line Fault Test Exit/Entry FollowerWI1424A 1/06 35  KeyFob Arm/Disarm chirp of Alarm Output Interior Stay BypassKeyFob Control of Relay Groups 1 Keypad Area AssignmentsWI1424A 1/06 37  Power-Up Delay Pre-Dial DelayMemory Failure Never Arm Do not use for primary Burglary protectionWI1424A 1/06 39  Report Digital Dialer Exit Error/Recent Closing Select Alarm Output for Keyfob ChirpRelay Follows Zone Report Telco 1 Report Telco 3 Double or Split ReportingWI1424A 1/06 41  Tamper EZM Tamper Keypad Tamper RF Tamper Wireless Tamper Temperature Display at Keypad Not evaluated by ULSwinger Shutdown WI1424A 1/06 43  Trouble on Open Trouble on Short Not for UL installations Wire, 4-Wire Smoke Detectors See Smoke Detectors Hour Zone WI1424A 1/06 45 Zone Status STANDBY-BATTERY Calculation Worksheet Battery Calculation WorksheetStandby Wiring Legend WI1424A 1/06 47 Function Mode Keypad Programming ModesKeypad Programming Modes Dealer Mode 49 Keypad Programming Modes Easy Menu Mode B456 123 DKeypad Programming Modes User Mode WI1424A 1/06 51 Keypad Configuration Mode Keypad Programming Modes Keypad Configuration ModeWI1424A 1/06 53  Programming AddressLocation Is selected in the Easy Program Menu GEM-P1664 Factory Default Description WI1424A 1/06 55 Out of Box Panel Operation Out of Box Panel Operation Prior to CP-01 Changes FCC Statement WI1424A 1/06 57 Page GEM-P1664 Wiring Diagram GEM-P1664 Wiring Diagram59  Napco Limited Warranty

GEM-P1664 specifications

Napco Security Technologies has long been a leader in the security industry, recognized for its innovative solutions that enhance safety and monitoring capabilities. One of its standout products is the GEM-P1664, a versatile and robust control panel designed for both residential and commercial security applications. This advanced system combines user-friendly features with cutting-edge technology, making it an ideal choice for those looking to bolster their security measures.

The GEM-P1664 boasts a 16-zone configuration, allowing users to monitor multiple areas within a property simultaneously. Each zone can be independently programmed, providing flexibility in how security is managed. This feature is particularly valuable for larger facilities or homes with multiple entry points, as it ensures that all areas are adequately protected. The panel supports both hardwired and wireless zones, delivering versatility to suit various installation preferences.

One of the core technologies integrated into the GEM-P1664 is the use of Event Management and Reporting tools. The panel can automatically log security events, sending alerts via email or SMS in real-time. This capability is essential for maintaining awareness of security status, allowing users to respond promptly to any unauthorized access or unusual activity.

The user interface of the GEM-P1664 is designed with simplicity in mind. Its intuitive layout and navigation make it easy for both trained professionals and everyday users to operate the system without extensive technical knowledge. Additionally, the panel supports multiple user codes, allowing different levels of access for family members or staff, enhancing both security and convenience.

Another notable characteristic of the GEM-P1664 is its compatibility with various Napco peripherals and add-ons, including motion detectors, door/window sensors, and surveillance cameras. This interoperability enables users to create a comprehensive security ecosystem tailored to their specific needs. Furthermore, the GEM-P1664 is also compatible with mobile applications, allowing clients to monitor their security systems remotely via smartphones or tablets.

Lastly, the GEM-P1664 is built with future-proofing in mind. It is designed to be easily upgradable, ensuring that users can incorporate the latest technological advancements and security features as they become available. This forward-thinking approach ensures that the investment in the GEM-P1664 remains relevant and effective over time.

In summary, the Napco Security Technologies GEM-P1664 control panel is a powerful and flexible solution for anyone looking to enhance their security infrastructure. With its robust zone configuration, user-friendly interface, advanced reporting capabilities, and compatibility with a range of devices, the GEM-P1664 stands out as a top choice in the security technology landscape.