KEYPAD CONFIGURATION MODE

This section will focus on configuring the GEM-RP1CAe2/GEM-K1CA and GEM-RP2ASe2/GEM-K2AS Keypads. We recommend that either a GEM-RP1CAe2 or a GEM-K1CA keypad be used for programming.

KEYPAD INSTALLATION

Each keypad must be assigned an address number (1–7) and each requires its own configuration procedure (see CONFIGURING THE KEYPADS, which follows, and DIRECT ADDRESS KEYPAD AREA OPTIONS). At least 1 keypad must be used; only 1 is required for a single-area Commercial Burglary installation.

GEM-RP1CAe2/GEM-K1CA- is a 2-line combination fire/burglary/access keypad capable of supporting 4 EZM zones. A GEM- RP1CAe2 or GEM-K1CA is recommended for use with programming.

GEM-RP2ASe2/GEM-K2AS- is a utility LCD keypad combining several preset LCD words with a limited message line. NOTE: Due to space constraints, available messages are abbreviated and will scroll automatically.

CONFIGURING THE KEYPADS

A total of up to 7 keypads may be connected to the panel. GEM-RP1CAe2/GEM-K1CA and GEM-RP2ASe2/GEM-K2AS keypads may be intermixed but require different configuration procedures, as described in the following paragraphs. If you have a GEM-K1CA key- pad, please see the "Important Note" on page 5 regarding the differences between the GEM-RP1CAe2 and the GEM-K1CA keypad buttons. The buttons displayed below will be for the GEM-K1CA keypad.

Configuring the GEM-RP1CAe2/GEM-K1CA Keypad

Each GEM-RP1CAe2/GEM-K1CA keypad must be configured for (a) keypad tactile beep; (b) entry

 

sounder; (c) keypad address; (d) EZM address; and (e) zone response.

NORMAL

To enter the GEM-RP1CAe2/GEM-K1CA Configuration Mode:

KEYPAD

1. Move jumper JP1 (located at the upper center of the control panel board) from Pins 1-2 (top two) to

CONFIGURE

Pins 2-3 (bottom two). NOTE: See the Wiring Diagram.

 

2.After about 15 seconds, the display will read “XX OUT OF SYSTEM”, where XX indicates the keypad address.

3.Press 11123Rand proceed as follows. (Repeat the following procedure for all keypads.)

Keypad Configuration

Keypad Beep

ON

Keypad Tactile Beep

Upon entering the Keypad Configuration Mode, “KEYPAD BEEP ON” will be displayed, indicating that the tactile beep, which sounds when any button is pressed, is on.

To turn off the tactile beep, press the Uor Dbutton (the Uor Dbutton will

toggle the tactile beep on and off). Press the Aor Rbutton to continue or press the Cbutton to exit.

Mode

Entry Sounder

Entry Sounder

ON

To turn off the keypad sounder during entry time, press the Uor Dbutton (the

 

Uor Dbutton will toggle the entry sounder on and off). Press the Aor

 

Rbutton to continue or press the Cbutton to exit.

Keypad Address

Keypad Address

01

If more than one keypad is installed, each must be assigned a unique keypad

 

address (that is, no two keypads may be numbered alike):

 

 

keypads must be numbered consecutively (missing numbers are not

 

permitted)

To assign the keypad number, proceed as follows:

1.Enter the assigned keypad number 01–07, then press the Uor Dbutton to save. A valid number will be acknowledged by a short beep; an invalid number will be rejected by a long beep.

2.Press the Aor Rbutton to continue or press the Cbutton to exit.

LNAPCO Security Systems

X GEM-P1664 Installation Instructions

Image 17
Contents System Ready 09/01/05 1200 AM Napco WI1424A 1/06Changes from Previous Edition Important NoticeTable of Contents GEM-P1664 Installation Instructions Lnapco Security Systems FeaturesIntroduction Page WI1424A 1/06WI1424A 1/06 5  Communicator FeaturesGEM-P1664 SpecificationsOrdering Information Optional Accessories and PeripheralsOrdering Information System ComponentsSmoke detectors & Summary of UL Requirements Smoke Detectors, 4-WireSummary of UL Requirements ResidentialMounting InstallationControl Panel GroundingWiring WiringWireless Systems Adding Expansion ZonesWI1424A 1/06 11  Testing the SystemSignal Strength Testing/Wireless Systems SIREN/BELL Power Wiring ConnectionsAuxiliary Power PGM OutputsRemote BUS Wiring Connections Remote Bus & Earth GroundEarth Ground WI1424A 1/06 13 EZ Zone Doublingtm Configuration WI1424A 1/06 15  Wire Smoke DetectorsTelephone Lines Wiring Connections Telephone LinesKeypad Installation Keypad Configuration ModeConfiguring the Keypads ModeCompatibility Number Not Applicable Keypad Configuration ModeEZM Address Zone ResponseDisable Sounder Keypad ConfigurationKeypad Address Touchpad Back LightUser Codes & Zone Descriptions Basic OperationBasic Operation Arming Arming and Disarming the SystemAuto Arming Not for UL Installations Display ZN Faults Alarm IndicationWI1424A 1/06 23  Bypassing ZonesReset System Trbl Display Fire AlarmDisplay ZN Bypassed Display ZN DirectoryEnable User Mode Enable Dealer ModeActivate Program Activate DownloadKeypad Messages Keypad MessagesGlossary AC Failure AC-Fail Report DelayGlossary WI1424A 1/06 27 Areas Zone Area 1-Zone Area 4 Priority Area Arming Alarm OutputsAmbush Keypad Ambush Ambush Codes Enable Global Ambush Backup Report on Telco 1/Telco Auto Status DisableBattery WI1424A 1/06 29 Chirp Output on Keyfob Arm/Disarm Chime ZoneCold Start Data FormatDate/Time WI1424A 1/06 31 Digital Dialer Report Enter/Exit Test Mode Dial-Tone Detection Disable Auto Dial-Tone DetectionDisable Call Waiting Touch-tone Dialing Only Disable Call Waiting on 1st AttemptWI1424A 1/06 33  Enable TCP/IP Communications Enable CP-01 LimitsEnable Telephone Line Fault Test Exit/Entry FollowerWI1424A 1/06 35  Interior Stay Bypass KeyFob Arm/Disarm chirp of Alarm OutputKeyFob Control of Relay Groups 1 Keypad Area AssignmentsWI1424A 1/06 37  Pre-Dial Delay Power-Up DelayMemory Failure Never Arm Do not use for primary Burglary protectionWI1424A 1/06 39  Select Alarm Output for Keyfob Chirp Report Digital Dialer Exit Error/Recent ClosingRelay Follows Zone Report Telco 1 Report Telco 3 Double or Split ReportingWI1424A 1/06 41  Swinger Shutdown Tamper EZM Tamper Keypad Tamper RF Tamper Wireless TamperTemperature Display at Keypad Not evaluated by UL WI1424A 1/06 43  Trouble on Open Trouble on Short Not for UL installations Zone Status Wire, 4-Wire Smoke Detectors See Smoke Detectors Hour ZoneWI1424A 1/06 45  Standby STANDBY-BATTERY Calculation WorksheetBattery Calculation Worksheet WI1424A 1/06 47  Wiring LegendKeypad Programming Modes Function Mode49  Keypad Programming Modes Dealer ModeB456 123 D Keypad Programming Modes Easy Menu ModeWI1424A 1/06 51  Keypad Programming Modes User ModeKeypad Programming Modes Keypad Configuration Mode Keypad Configuration ModeLocation WI1424A 1/06 53 Programming Address Is selected in the Easy Program Menu Out of Box Panel Operation GEM-P1664 Factory Default DescriptionWI1424A 1/06 55  Out of Box Panel Operation Prior to CP-01 Changes WI1424A 1/06 57  FCC StatementPage 59  GEM-P1664 Wiring DiagramGEM-P1664 Wiring Diagram Napco Limited Warranty

GEM-P1664 specifications

Napco Security Technologies has long been a leader in the security industry, recognized for its innovative solutions that enhance safety and monitoring capabilities. One of its standout products is the GEM-P1664, a versatile and robust control panel designed for both residential and commercial security applications. This advanced system combines user-friendly features with cutting-edge technology, making it an ideal choice for those looking to bolster their security measures.

The GEM-P1664 boasts a 16-zone configuration, allowing users to monitor multiple areas within a property simultaneously. Each zone can be independently programmed, providing flexibility in how security is managed. This feature is particularly valuable for larger facilities or homes with multiple entry points, as it ensures that all areas are adequately protected. The panel supports both hardwired and wireless zones, delivering versatility to suit various installation preferences.

One of the core technologies integrated into the GEM-P1664 is the use of Event Management and Reporting tools. The panel can automatically log security events, sending alerts via email or SMS in real-time. This capability is essential for maintaining awareness of security status, allowing users to respond promptly to any unauthorized access or unusual activity.

The user interface of the GEM-P1664 is designed with simplicity in mind. Its intuitive layout and navigation make it easy for both trained professionals and everyday users to operate the system without extensive technical knowledge. Additionally, the panel supports multiple user codes, allowing different levels of access for family members or staff, enhancing both security and convenience.

Another notable characteristic of the GEM-P1664 is its compatibility with various Napco peripherals and add-ons, including motion detectors, door/window sensors, and surveillance cameras. This interoperability enables users to create a comprehensive security ecosystem tailored to their specific needs. Furthermore, the GEM-P1664 is also compatible with mobile applications, allowing clients to monitor their security systems remotely via smartphones or tablets.

Lastly, the GEM-P1664 is built with future-proofing in mind. It is designed to be easily upgradable, ensuring that users can incorporate the latest technological advancements and security features as they become available. This forward-thinking approach ensures that the investment in the GEM-P1664 remains relevant and effective over time.

In summary, the Napco Security Technologies GEM-P1664 control panel is a powerful and flexible solution for anyone looking to enhance their security infrastructure. With its robust zone configuration, user-friendly interface, advanced reporting capabilities, and compatibility with a range of devices, the GEM-P1664 stands out as a top choice in the security technology landscape.