Napco Security Technologies GEM-P1664 Out of Box Panel Operation Prior to CP-01 Changes

Page 56

Page 56

WI1424A 1/06

10.Alarm and Pulse Alarm time-outs are 15 minutes.

11.Chime is set to 2 seconds.

12.Change Pulse Alarm to Cadence Alarm is enabled.

13.Auto Reset after Burglary Output Timeout is enabled.

If the answer to the question “Enable CP-01 Features? Y/N” is “Yes”, then the following changes to the above program occur:

1.Auto Reset and Swinger Shutdown are removed from burg zones.

2.1422-Bit 6 "Chirp Output on Keyfob Arm/Disarm" is enabled.

3.1424-Bit 0 "Automatic Interior Bypass/Easy Exit" is enabled.

4.1423-Bit 7 "Select Alarm Output for Keyfob Chirp" is enabled.

5.2053-Bit 0 "Exit Time Restart" is enabled.

6.2053-Bit 1 "Sound Alarm on Exit Error" is enabled.

7.2053-Bit 2 "Report Digital Dialer Exit Error/Recent Closing" is enabled.

8.2053-Bit 3 "Enable CP-01 Limits" is enabled.

9.2053-Bit 4 "Digital Dialer Report Enter/Exit Test Mode" is enabled.

10.1417 "Abort Delay" is changed to 30 seconds.

11.Cancel Time ("Cancel Window Duration") is set to 7 minutes.

Subsequent entering of the Dealer Program allows only a subset of the Easy Program Menu which does not include the ques- tion “Enable CP-01 Features” and prevents the existing program from being deleted, but allows the system to be expanded. The CP-01 Quick Reference Chart (see pages 59-60 of this manual) and the explanation of the Easy Program Question “Enable CP-01” (above) should be reviewed before installing the panel.

Note: When address 2053 "Enable CP-01 Limits" is enabled, the Exit Delay keypad sounder (including the Exit Urgency sound during the final 10 seconds of the Exit Delay) is enabled.

Out of Box Panel Operation (Prior to CP-01 Changes)

The following describes the control panel factory defaults that are loaded if you enter the Dealer Program Menu, which is also the factory default used with these panels prior to modifications made in order to comply with the CP-01 requirements:

The program has minimum defaults, programmed with 8 hardwire zones (Zones 1-8) programmed in Area 1. No other zone features were enabled and no alarms could be generated. Other features included:

1)Default User 1 Code = "123" and enabled as an Arming Code in Area 1.

2)Dealer Program Default Code = "456789".

After powering up, the installer is required to enter Program Mode using the Dealer Program Default Code of "456789".

The Easy Program mode that is entered is a series of questions regarding the required functions of the particular installation. After exiting the Easy Program Mode, the installer could complete the installation. Subsequent entering of Dealer Program Mode allows only a subset of the Easy Program menu that prevents the existing program from being deleted, but allows the system to be expanded.

X GEM-P1664 Installation Instructions

LNAPCO Security Systems

Image 56
Contents Napco WI1424A 1/06 System Ready 09/01/05 1200 AMImportant Notice Changes from Previous EditionTable of Contents Features GEM-P1664 Installation Instructions Lnapco Security SystemsIntroduction Page WI1424A 1/06Communicator Features WI1424A 1/06 5 Specifications GEM-P1664Optional Accessories and Peripherals Ordering InformationOrdering Information System ComponentsSmoke Detectors, 4-Wire Smoke detectors & Summary of UL RequirementsSummary of UL Requirements ResidentialInstallation MountingControl Panel GroundingWiring WiringWireless Systems Adding Expansion ZonesWI1424A 1/06 11  Testing the SystemSignal Strength Testing/Wireless Systems Wiring Connections SIREN/BELL PowerAuxiliary Power PGM OutputsWiring Connections Remote Bus & Earth Ground Remote BUSEarth Ground WI1424A 1/06 13 EZ Zone Doublingtm Configuration Wire Smoke Detectors WI1424A 1/06 15 Wiring Connections Telephone Lines Telephone LinesKeypad Configuration Mode Keypad InstallationConfiguring the Keypads ModeKeypad Configuration Mode Compatibility Number Not ApplicableEZM Address Zone ResponseKeypad Configuration Disable SounderKeypad Address Touchpad Back LightUser Codes & Zone Descriptions Basic OperationBasic Operation Arming and Disarming the System ArmingAuto Arming Not for UL Installations Alarm Indication Display ZN FaultsWI1424A 1/06 23  Bypassing ZonesDisplay Fire Alarm Reset System TrblDisplay ZN Bypassed Display ZN DirectoryEnable Dealer Mode Enable User ModeActivate Program Activate DownloadKeypad Messages Keypad MessagesAC Failure AC-Fail Report Delay GlossaryGlossary WI1424A 1/06 27 Areas Zone Area 1-Zone Area 4 Priority Area Arming Alarm OutputsAmbush Keypad Ambush Ambush Codes Enable Global Ambush Auto Status Disable Backup Report on Telco 1/TelcoBattery WI1424A 1/06 29 Chime Zone Chirp Output on Keyfob Arm/DisarmCold Start Data FormatWI1424A 1/06 31  Date/TimeDial-Tone Detection Disable Auto Dial-Tone Detection Digital Dialer Report Enter/Exit Test ModeDisable Call Waiting Touch-tone Dialing Only Disable Call Waiting on 1st AttemptWI1424A 1/06 33  Enable CP-01 Limits Enable TCP/IP CommunicationsEnable Telephone Line Fault Test Exit/Entry FollowerWI1424A 1/06 35  KeyFob Arm/Disarm chirp of Alarm Output Interior Stay BypassKeyFob Control of Relay Groups 1 Keypad Area AssignmentsWI1424A 1/06 37  Power-Up Delay Pre-Dial DelayMemory Failure Never Arm Do not use for primary Burglary protectionWI1424A 1/06 39  Report Digital Dialer Exit Error/Recent Closing Select Alarm Output for Keyfob ChirpRelay Follows Zone Report Telco 1 Report Telco 3 Double or Split ReportingWI1424A 1/06 41  Swinger Shutdown Tamper EZM Tamper Keypad Tamper RF Tamper Wireless TamperTemperature Display at Keypad Not evaluated by UL WI1424A 1/06 43  Trouble on Open Trouble on Short Not for UL installations Zone Status Wire, 4-Wire Smoke Detectors See Smoke Detectors Hour ZoneWI1424A 1/06 45  Standby STANDBY-BATTERY Calculation WorksheetBattery Calculation Worksheet Wiring Legend WI1424A 1/06 47 Function Mode Keypad Programming ModesKeypad Programming Modes Dealer Mode 49 Keypad Programming Modes Easy Menu Mode B456 123 DKeypad Programming Modes User Mode WI1424A 1/06 51 Keypad Configuration Mode Keypad Programming Modes Keypad Configuration ModeLocation WI1424A 1/06 53 Programming Address Is selected in the Easy Program Menu Out of Box Panel Operation GEM-P1664 Factory Default DescriptionWI1424A 1/06 55  Out of Box Panel Operation Prior to CP-01 Changes FCC Statement WI1424A 1/06 57 Page 59  GEM-P1664 Wiring DiagramGEM-P1664 Wiring Diagram Napco Limited Warranty

GEM-P1664 specifications

Napco Security Technologies has long been a leader in the security industry, recognized for its innovative solutions that enhance safety and monitoring capabilities. One of its standout products is the GEM-P1664, a versatile and robust control panel designed for both residential and commercial security applications. This advanced system combines user-friendly features with cutting-edge technology, making it an ideal choice for those looking to bolster their security measures.

The GEM-P1664 boasts a 16-zone configuration, allowing users to monitor multiple areas within a property simultaneously. Each zone can be independently programmed, providing flexibility in how security is managed. This feature is particularly valuable for larger facilities or homes with multiple entry points, as it ensures that all areas are adequately protected. The panel supports both hardwired and wireless zones, delivering versatility to suit various installation preferences.

One of the core technologies integrated into the GEM-P1664 is the use of Event Management and Reporting tools. The panel can automatically log security events, sending alerts via email or SMS in real-time. This capability is essential for maintaining awareness of security status, allowing users to respond promptly to any unauthorized access or unusual activity.

The user interface of the GEM-P1664 is designed with simplicity in mind. Its intuitive layout and navigation make it easy for both trained professionals and everyday users to operate the system without extensive technical knowledge. Additionally, the panel supports multiple user codes, allowing different levels of access for family members or staff, enhancing both security and convenience.

Another notable characteristic of the GEM-P1664 is its compatibility with various Napco peripherals and add-ons, including motion detectors, door/window sensors, and surveillance cameras. This interoperability enables users to create a comprehensive security ecosystem tailored to their specific needs. Furthermore, the GEM-P1664 is also compatible with mobile applications, allowing clients to monitor their security systems remotely via smartphones or tablets.

Lastly, the GEM-P1664 is built with future-proofing in mind. It is designed to be easily upgradable, ensuring that users can incorporate the latest technological advancements and security features as they become available. This forward-thinking approach ensures that the investment in the GEM-P1664 remains relevant and effective over time.

In summary, the Napco Security Technologies GEM-P1664 control panel is a powerful and flexible solution for anyone looking to enhance their security infrastructure. With its robust zone configuration, user-friendly interface, advanced reporting capabilities, and compatibility with a range of devices, the GEM-P1664 stands out as a top choice in the security technology landscape.