Napco Security Technologies GEM-P1664 Introduction, Features, Page WI1424A 1/06

Page 4

Features

Page 4

WI1424A 1/06

INTRODUCTION

GENERAL DESCRIPTION

Napco's Gemini GEM-P1664 is a state-of-the-art microcomputer-based burglary and residential fire alarm control panel of modular design. Integrally an 8-zone panel, it will support up to 64 zones with the use of zone doubling, optional zone expansion modules, wireless receiver modules and/or GEM-RP1CAe2/GEM-K1CA Keypads. Each panel includes an integral digital communicator.

The control panel features programmable area partitioning. That is, the system may be divided into up to 4 discrete multiple-zone areas, each allowing access by only those users programmed for their respective area.

Opening Suppression and Closing Suppression, available through Napco Quickloader software, suppress reporting within programmed “windows”. Conversely, Exception Reporting can transmit a “fail to close” if the panel is not armed within programmed intervals and, similarly, a “fail to open” if the panel is not disarmed within programmed intervals. Furthermore, the panel can be programmed to automatically arm either area at any time. A log containing up to 400 events (accessible through QuickloaderTM software) monitors control-panel activity referenced to a precision real-time clock. A detailed event history may be displayed at the computer, using Napco’s PCD-Windows Quickloader Software.

Keypads feature a liquid-crystal display for messages. In normal use, the LCD shows zone identification and status messages, and the log can also be viewed. Conventional LEDs and a sounder are also provided for annunciation.

Data may be quickly and easily downloaded to the control panel using a PC-compatible computer with Napco's PCD- Windows Quickloader software and PCI2000 computer interface. Or, the panel may be programmed using the keypad in its secondary mode of operation. In the keypad programming modes (there are two: Dealer and User), the LCD shows memory address, data values, programming prompts, and the alphanumeric characters required for entering up to 64 user codes and custom zone descriptions.

NOTE: Failure to install and program as described in this manual for UL-listed systems voids the listing mark of Underwriters Laboratories, Inc.

FEATURES

Control Panel Features

Eight end-of-line-resistor burglary zones programmable for Area (expandable to sixteen end-of-line resistors with zone doubling or series zone doubling with loop supervision), Exit/Entry Delay, Interior (Stay) Bypass, Exit/Entry Follower, Day Zone, Chime, Fire options, Swinger Shutdown, Zone Anding and a variety of other features.

Supports up to 64 zones with optional zone-expansion modules, wireless receiver modules and 4-zone keypads.

Supports up to 64 individually coded users.

Supports three outputs (Bell, PGM1 and PGM2) and up to 16 external outputs (using Relay Module RB3008, RM3008 or the GEM-OUT8. See Relay Control in glossary for more information).

Supports three keypad panics: Fire, Police & Auxiliary.

Supports four independent area partitions.

Supports up to seven separate access stations (keypads) by up to 64 users.

Supports up to 16 separately-addressable X-10 devices with the GEM-X10 KIT and PC04 interfaces.

English-language prompts & system status messages.

User Codes and Zone Descriptions outside assigned areas are able to be blocked from keypad display.

User-customized zone descriptions, re-programmable as required.

Supports 2-wire and 4-wire smoke detectors.

Reports alarms, restores and troubles by zone.

400 Event Log.

Two programmable entry delay times.

One Interior Zone Group.

Dynamic battery test interrupts charging and places battery under load every four hours.

Two Chimes by zone; programmable duration.

Quickloader programmable.

2 PGM outputs.

Supports Gemini Wireless Devices.

X GEM-P1664 Installation Instructions

LNAPCO Security Systems

Image 4
Contents Napco WI1424A 1/06 System Ready 09/01/05 1200 AMImportant Notice Changes from Previous EditionTable of Contents Features GEM-P1664 Installation Instructions Lnapco Security SystemsIntroduction Page WI1424A 1/06Communicator Features WI1424A 1/06 5 Specifications GEM-P1664Optional Accessories and Peripherals Ordering InformationOrdering Information System ComponentsSmoke Detectors, 4-Wire Smoke detectors & Summary of UL RequirementsSummary of UL Requirements ResidentialInstallation MountingControl Panel GroundingWiring WiringWireless Systems Adding Expansion ZonesSignal Strength Testing/Wireless Systems Testing the SystemWI1424A 1/06 11  Wiring Connections SIREN/BELL PowerAuxiliary Power PGM OutputsWiring Connections Remote Bus & Earth Ground Remote BUSEarth Ground WI1424A 1/06 13 EZ Zone Doublingtm Configuration Wire Smoke Detectors WI1424A 1/06 15 Wiring Connections Telephone Lines Telephone LinesKeypad Configuration Mode Keypad InstallationConfiguring the Keypads ModeKeypad Configuration Mode Compatibility Number Not ApplicableEZM Address Zone ResponseKeypad Configuration Disable SounderKeypad Address Touchpad Back LightBasic Operation Basic OperationUser Codes & Zone Descriptions Arming and Disarming the System ArmingAuto Arming Not for UL Installations Alarm Indication Display ZN FaultsWI1424A 1/06 23  Bypassing ZonesDisplay Fire Alarm Reset System TrblDisplay ZN Bypassed Display ZN DirectoryEnable Dealer Mode Enable User ModeActivate Program Activate DownloadKeypad Messages Keypad MessagesAC Failure AC-Fail Report Delay GlossaryGlossary WI1424A 1/06 27 Ambush Keypad Ambush Ambush Codes Enable Global Ambush Alarm OutputsAreas Zone Area 1-Zone Area 4 Priority Area Arming Auto Status Disable Backup Report on Telco 1/TelcoBattery WI1424A 1/06 29 Chime Zone Chirp Output on Keyfob Arm/DisarmCold Start Data FormatWI1424A 1/06 31  Date/TimeDial-Tone Detection Disable Auto Dial-Tone Detection Digital Dialer Report Enter/Exit Test ModeDisable Call Waiting Touch-tone Dialing Only Disable Call Waiting on 1st AttemptWI1424A 1/06 33  Enable CP-01 Limits Enable TCP/IP CommunicationsEnable Telephone Line Fault Test Exit/Entry FollowerWI1424A 1/06 35  KeyFob Arm/Disarm chirp of Alarm Output Interior Stay BypassKeyFob Control of Relay Groups 1 Keypad Area AssignmentsWI1424A 1/06 37  Power-Up Delay Pre-Dial DelayMemory Failure Never Arm Do not use for primary Burglary protectionWI1424A 1/06 39  Report Digital Dialer Exit Error/Recent Closing Select Alarm Output for Keyfob ChirpRelay Follows Zone Report Telco 1 Report Telco 3 Double or Split ReportingWI1424A 1/06 41  Temperature Display at Keypad Not evaluated by UL Tamper EZM Tamper Keypad Tamper RF Tamper Wireless TamperSwinger Shutdown WI1424A 1/06 43  Trouble on Open Trouble on Short Not for UL installations WI1424A 1/06 45  Wire, 4-Wire Smoke Detectors See Smoke Detectors Hour ZoneZone Status Battery Calculation Worksheet STANDBY-BATTERY Calculation WorksheetStandby Wiring Legend WI1424A 1/06 47 Function Mode Keypad Programming ModesKeypad Programming Modes Dealer Mode 49 Keypad Programming Modes Easy Menu Mode B456 123 DKeypad Programming Modes User Mode WI1424A 1/06 51 Keypad Configuration Mode Keypad Programming Modes Keypad Configuration ModeProgramming Address WI1424A 1/06 53 Location Is selected in the Easy Program Menu WI1424A 1/06 55  GEM-P1664 Factory Default DescriptionOut of Box Panel Operation Out of Box Panel Operation Prior to CP-01 Changes FCC Statement WI1424A 1/06 57 Page GEM-P1664 Wiring Diagram GEM-P1664 Wiring Diagram59  Napco Limited Warranty

GEM-P1664 specifications

Napco Security Technologies has long been a leader in the security industry, recognized for its innovative solutions that enhance safety and monitoring capabilities. One of its standout products is the GEM-P1664, a versatile and robust control panel designed for both residential and commercial security applications. This advanced system combines user-friendly features with cutting-edge technology, making it an ideal choice for those looking to bolster their security measures.

The GEM-P1664 boasts a 16-zone configuration, allowing users to monitor multiple areas within a property simultaneously. Each zone can be independently programmed, providing flexibility in how security is managed. This feature is particularly valuable for larger facilities or homes with multiple entry points, as it ensures that all areas are adequately protected. The panel supports both hardwired and wireless zones, delivering versatility to suit various installation preferences.

One of the core technologies integrated into the GEM-P1664 is the use of Event Management and Reporting tools. The panel can automatically log security events, sending alerts via email or SMS in real-time. This capability is essential for maintaining awareness of security status, allowing users to respond promptly to any unauthorized access or unusual activity.

The user interface of the GEM-P1664 is designed with simplicity in mind. Its intuitive layout and navigation make it easy for both trained professionals and everyday users to operate the system without extensive technical knowledge. Additionally, the panel supports multiple user codes, allowing different levels of access for family members or staff, enhancing both security and convenience.

Another notable characteristic of the GEM-P1664 is its compatibility with various Napco peripherals and add-ons, including motion detectors, door/window sensors, and surveillance cameras. This interoperability enables users to create a comprehensive security ecosystem tailored to their specific needs. Furthermore, the GEM-P1664 is also compatible with mobile applications, allowing clients to monitor their security systems remotely via smartphones or tablets.

Lastly, the GEM-P1664 is built with future-proofing in mind. It is designed to be easily upgradable, ensuring that users can incorporate the latest technological advancements and security features as they become available. This forward-thinking approach ensures that the investment in the GEM-P1664 remains relevant and effective over time.

In summary, the Napco Security Technologies GEM-P1664 control panel is a powerful and flexible solution for anyone looking to enhance their security infrastructure. With its robust zone configuration, user-friendly interface, advanced reporting capabilities, and compatibility with a range of devices, the GEM-P1664 stands out as a top choice in the security technology landscape.