Napco Security Technologies GEM-P1664 Auto Arming Not for UL Installations

Page 22

Basic Operation

Page 22

WI1424A 1/06

Auto Arming (Not for UL Installations)

AUTO ARM allows the User to automatically arm the system at a specified time of the day and on specific days of the week. Schedule a specific closing time on any/all day(s) of the week. After a specific Fail-to-Close Window Start Time, if the user has not Armed the system during the Window Length, and the system has been instructed to “Fail-to- Close’ and ‘Auto Arm if not closed at end of Window” then the system will arm, providing a 15 minute warning. CAU- TION: If Automatic Interior Bypass is selected, panel will Auto Arm in STAY Mode.

Delaying an Auto Arm (Not for UL Installations)

During the 15 minute pulsating sounder warning of an Auto Arm, a User can press the Ror Abutton, until “TO DELAY AUTO ARM / PRESS 1-4 / N” is displayed. Enter the number of hours (1-4) to delay arming, followed by the Uor Dbutton. If “DELAY AUTO ARM Y/N” is displayed, press the “NEXT/YES” button. The sounder can be silenced by pressing the Cbutton during the 15 minute interval, but will come back on in the last 1 minute. This feature may be canceled by arming and disarming the keypad.

EZ Arm (Easy Arm)

EASY ARM provides one button arming for non-security critical premises. Select Easy Arming for each Keypad, with optional reporting of Easy Arm Closings as User 67. Disarming still requires a valid user code.

To arm, press the Dbutton for "Classic" keypads;

To arm, press and hold Por Qfor 3 seconds for "K Series" keypads.

Keyswitch Arming

KEYSWITCH ARMING allows a zone input to be used to arm/disarm. The area will arm/disarm when the zone is momentarily shorted through a Momentary Switch. An end-of-line resistor must be used. Select Keyswitch Arm to optionally report as User 68.

Maintained-Key Input Arming

KEYSWITCH ARMING with MAINTAINED-KEY INPUT ARMING is similar to Keyswitch arming, except the zone input must remain shorted to be armed and remain open to be disarmed.

Remote Arming (Not for UL Installations)

REMOTE ARMING allows computer software control of arming/disarming of the system for non-security critical installations. Select Remote Arm to optionally report as User 66.

Priority Arming

A 2-second tone and “CAN’T ARM SYSTEM/ZONE FAULTED” displayed when attempting to arm indicates a priority condition; that is, a problem exists on at least one zone that has been designated as a Priority Zone, or a system trouble exists. The trouble(s) must be corrected before the panel can be armed. The display will read “ZONE FAULTED”, then automatically scroll through all unsecured zones. If a system trouble is indicated, it will display the system trouble.

Area Arming/Manager’s Mode

In a partitioned system, either or both secured areas may be armed (or disarmed) from the Manager's Mode (if enabled). The Manager's Mode, is a low-security mode of operation. It provides quick access to other areas without having to go to another keypad of another area.

To arm or disarm the alternate area (for "Classic" keypads):

1.Press the 1, 2, 3or 4buttons to represent the alternate area.

2.Press the Gbutton, then the Uor Dbutton.

3.Arm or disarm the selected area using your user code (the user code must be valid for that area).

4.To return the keypad to its “home” area, press the Gbutton, then the Uor Dbutton.

Note: If the “home” keypad has been changed to the alternate area and unused for more than 5 minutes, it will revert to the home area.

X GEM-P1664 Installation Instructions

LNAPCO Security Systems

Image 22
Contents Napco WI1424A 1/06 System Ready 09/01/05 1200 AMImportant Notice Changes from Previous EditionTable of Contents Introduction FeaturesGEM-P1664 Installation Instructions Lnapco Security Systems Page WI1424A 1/06Communicator Features WI1424A 1/06 5 Specifications GEM-P1664Ordering Information Optional Accessories and PeripheralsOrdering Information System ComponentsSummary of UL Requirements Smoke Detectors, 4-WireSmoke detectors & Summary of UL Requirements ResidentialControl Panel InstallationMounting GroundingWireless Systems WiringWiring Adding Expansion ZonesSignal Strength Testing/Wireless Systems Testing the SystemWI1424A 1/06 11  Auxiliary Power Wiring ConnectionsSIREN/BELL Power PGM OutputsEarth Ground Wiring Connections Remote Bus & Earth GroundRemote BUS WI1424A 1/06 13 EZ Zone Doublingtm Configuration Wire Smoke Detectors WI1424A 1/06 15 Wiring Connections Telephone Lines Telephone LinesConfiguring the Keypads Keypad Configuration ModeKeypad Installation ModeEZM Address Keypad Configuration ModeCompatibility Number Not Applicable Zone ResponseKeypad Address Keypad ConfigurationDisable Sounder Touchpad Back LightBasic Operation Basic OperationUser Codes & Zone Descriptions Arming and Disarming the System ArmingAuto Arming Not for UL Installations WI1424A 1/06 23  Alarm IndicationDisplay ZN Faults Bypassing ZonesDisplay ZN Bypassed Display Fire AlarmReset System Trbl Display ZN DirectoryActivate Program Enable Dealer ModeEnable User Mode Activate DownloadKeypad Messages Keypad MessagesGlossary AC Failure AC-Fail Report DelayGlossary WI1424A 1/06 27 Ambush Keypad Ambush Ambush Codes Enable Global Ambush Alarm OutputsAreas Zone Area 1-Zone Area 4 Priority Area Arming Battery Auto Status DisableBackup Report on Telco 1/Telco WI1424A 1/06 29 Cold Start Chime ZoneChirp Output on Keyfob Arm/Disarm Data FormatWI1424A 1/06 31  Date/TimeDisable Call Waiting Touch-tone Dialing Only Dial-Tone Detection Disable Auto Dial-Tone DetectionDigital Dialer Report Enter/Exit Test Mode Disable Call Waiting on 1st AttemptWI1424A 1/06 33  Enable Telephone Line Fault Test Enable CP-01 LimitsEnable TCP/IP Communications Exit/Entry FollowerWI1424A 1/06 35  KeyFob Control of Relay Groups 1 KeyFob Arm/Disarm chirp of Alarm OutputInterior Stay Bypass Keypad Area AssignmentsWI1424A 1/06 37  Memory Failure Power-Up DelayPre-Dial Delay Never Arm Do not use for primary Burglary protectionWI1424A 1/06 39  Relay Follows Zone Report Digital Dialer Exit Error/Recent ClosingSelect Alarm Output for Keyfob Chirp Report Telco 1 Report Telco 3 Double or Split ReportingWI1424A 1/06 41  Temperature Display at Keypad Not evaluated by UL Tamper EZM Tamper Keypad Tamper RF Tamper Wireless TamperSwinger Shutdown WI1424A 1/06 43  Trouble on Open Trouble on Short Not for UL installations WI1424A 1/06 45  Wire, 4-Wire Smoke Detectors See Smoke Detectors Hour ZoneZone Status Battery Calculation Worksheet STANDBY-BATTERY Calculation WorksheetStandby Wiring Legend WI1424A 1/06 47 Function Mode Keypad Programming ModesKeypad Programming Modes Dealer Mode 49 Keypad Programming Modes Easy Menu Mode B456 123 DKeypad Programming Modes User Mode WI1424A 1/06 51 Keypad Configuration Mode Keypad Programming Modes Keypad Configuration ModeProgramming Address WI1424A 1/06 53 Location Is selected in the Easy Program Menu WI1424A 1/06 55  GEM-P1664 Factory Default DescriptionOut of Box Panel Operation Out of Box Panel Operation Prior to CP-01 Changes FCC Statement WI1424A 1/06 57 Page GEM-P1664 Wiring Diagram GEM-P1664 Wiring Diagram59  Napco Limited Warranty

GEM-P1664 specifications

Napco Security Technologies has long been a leader in the security industry, recognized for its innovative solutions that enhance safety and monitoring capabilities. One of its standout products is the GEM-P1664, a versatile and robust control panel designed for both residential and commercial security applications. This advanced system combines user-friendly features with cutting-edge technology, making it an ideal choice for those looking to bolster their security measures.

The GEM-P1664 boasts a 16-zone configuration, allowing users to monitor multiple areas within a property simultaneously. Each zone can be independently programmed, providing flexibility in how security is managed. This feature is particularly valuable for larger facilities or homes with multiple entry points, as it ensures that all areas are adequately protected. The panel supports both hardwired and wireless zones, delivering versatility to suit various installation preferences.

One of the core technologies integrated into the GEM-P1664 is the use of Event Management and Reporting tools. The panel can automatically log security events, sending alerts via email or SMS in real-time. This capability is essential for maintaining awareness of security status, allowing users to respond promptly to any unauthorized access or unusual activity.

The user interface of the GEM-P1664 is designed with simplicity in mind. Its intuitive layout and navigation make it easy for both trained professionals and everyday users to operate the system without extensive technical knowledge. Additionally, the panel supports multiple user codes, allowing different levels of access for family members or staff, enhancing both security and convenience.

Another notable characteristic of the GEM-P1664 is its compatibility with various Napco peripherals and add-ons, including motion detectors, door/window sensors, and surveillance cameras. This interoperability enables users to create a comprehensive security ecosystem tailored to their specific needs. Furthermore, the GEM-P1664 is also compatible with mobile applications, allowing clients to monitor their security systems remotely via smartphones or tablets.

Lastly, the GEM-P1664 is built with future-proofing in mind. It is designed to be easily upgradable, ensuring that users can incorporate the latest technological advancements and security features as they become available. This forward-thinking approach ensures that the investment in the GEM-P1664 remains relevant and effective over time.

In summary, the Napco Security Technologies GEM-P1664 control panel is a powerful and flexible solution for anyone looking to enhance their security infrastructure. With its robust zone configuration, user-friendly interface, advanced reporting capabilities, and compatibility with a range of devices, the GEM-P1664 stands out as a top choice in the security technology landscape.