DISPLAY ZN BYPASSED

Press YES button to display zones that have been deactivated. Press NEXT button to scroll through the zones.

DISPLAY ZN DIRECTORY

Press YES button to display a list of all programmed zone descriptions in the keypad area. Press NEXT button to scroll through the zones. To return to the system, press the Cbutton at any time.

ACTIVATE BELL TEST

Press the NEXT/YES button to activate the burg relay output (while disarmed) for about 2 seconds. If the device does not sound, it may be defective.

DISPLAY FIRE ALARM

To display Fire Zone(s) in alarm, access DISPLAY FIRE ALARM and scroll through the zones using the NEXT but- ton. Correct the problem, then press the Cbutton to restore the "SYSTEM READY" condition.

DISPLAY FIRE TRBL

To display Fire Zone(s) in trouble, access DISPLAY FIRE TRBL and scroll through the zones using the NEXT but- ton. Correct the problem, then press the Cbutton to restore the "SYSTEM READY" condition.

ACTIVATE CHIME

Press the NEXT/YES button to sound a tone at the keypad when a Chime Zone is violated. The duration of the tone is programmable. To turn off the Chime Mode, press the NEXT/YES button at the DEACTIVATE CHIME function. Note: Chime is disabled for protected zones while armed. Never Armed zones (such as a driveway sensor) will continue to chime when the system is armed.

RESET SYSTEM TRBL

System troubles normally latch and display and sound at the keypad. Pressing the Cbutton will si- lence the sounder; "SYSTEM READY" will be displayed. Correcting the trouble will clear most system trouble indications, however the following system troubles require a reset system trouble be performed (enter code; access RESET SYS TRBL then press the Uor Dbutton).

Sensor Watch

Note: (1) If a system trouble is not corrected, it will redisplay after 5 minutes. (2) If one or more of the foregoing system troubles appear during the first 5 minutes after power-up, they will be cleared automatically.

DISPLAY ALARM LOG (Not available with GEM-RP2ASe2/GEM-K2AS or GEM-RP3DGTL/GEM-K3DGTL Keypads)

Displays most recent alarm events. Line 1 displays event and date. Line 2 displays time, area and zone. To check previous alarm events, scroll back using the PRIOR button.

DISPLAY TOTAL LOG (Not available with GEM-RP2ASe2/GEM-K2AS or GEM-RP3DGTL/GEM-K3DGTL Keypads)

Displays most recent events of all types. Line 1 displays event and date. Line 2 displays time and, if applicable, area and zone or user. To check previous events, scroll back using the PRIOR button.

DISPLAY FIRE LOG (Not available with GEM-RP2ASe2/GEM-K2AS or GEM-RP3DGTL/GEM-K3DGTL Keypads)

Displays most recent fire events. Line 1 displays event and date. Line 2 displays time, area and zone. To check previous fire events, scroll back using the PRIOR button.

DISPLAY OP/CL LOG (Not available with GEM-RP2ASe2/GEM-K2AS or GEM-RP3DGTL/GEM-K3DGTL Keypads)

Displays most recent openings and closings. Line 1 displays event and date. Line 2 displays time, area and user. To check previous events, scroll back using the PRIOR button.

DISPLAY SYSTEM LOG (Not available with GEM-RP2ASe2/GEM-K2AS or GEM-RP3DGTL/GEM-K3DGTL Key- pads)

Displays most recent system events. Line 1 displays event and date. Line 2 displays time and other pertinent in- formation, where necessary, depending upon event. To check previous system events, scroll back using the PRIOR button.

X GEM-P1664 Installation Instructions

LNAPCO Security Systems

Image 24
Contents Napco WI1424A 1/06 System Ready 09/01/05 1200 AMImportant Notice Changes from Previous EditionTable of Contents Features GEM-P1664 Installation Instructions Lnapco Security SystemsIntroduction Page WI1424A 1/06Communicator Features WI1424A 1/06 5 Specifications GEM-P1664Optional Accessories and Peripherals Ordering InformationOrdering Information System ComponentsSmoke Detectors, 4-Wire Smoke detectors & Summary of UL RequirementsSummary of UL Requirements ResidentialInstallation MountingControl Panel GroundingWiring WiringWireless Systems Adding Expansion ZonesTesting the System Signal Strength Testing/Wireless SystemsWI1424A 1/06 11  Wiring Connections SIREN/BELL PowerAuxiliary Power PGM OutputsWiring Connections Remote Bus & Earth Ground Remote BUSEarth Ground WI1424A 1/06 13 EZ Zone Doublingtm Configuration Wire Smoke Detectors WI1424A 1/06 15 Wiring Connections Telephone Lines Telephone LinesKeypad Configuration Mode Keypad InstallationConfiguring the Keypads ModeKeypad Configuration Mode Compatibility Number Not ApplicableEZM Address Zone ResponseKeypad Configuration Disable SounderKeypad Address Touchpad Back LightBasic Operation Basic OperationUser Codes & Zone Descriptions Arming and Disarming the System ArmingAuto Arming Not for UL Installations Alarm Indication Display ZN FaultsWI1424A 1/06 23  Bypassing ZonesDisplay Fire Alarm Reset System TrblDisplay ZN Bypassed Display ZN DirectoryEnable Dealer Mode Enable User ModeActivate Program Activate DownloadKeypad Messages Keypad MessagesAC Failure AC-Fail Report Delay GlossaryGlossary WI1424A 1/06 27 Alarm Outputs Ambush Keypad Ambush Ambush Codes Enable Global AmbushAreas Zone Area 1-Zone Area 4 Priority Area Arming Auto Status Disable Backup Report on Telco 1/TelcoBattery WI1424A 1/06 29 Chime Zone Chirp Output on Keyfob Arm/DisarmCold Start Data FormatWI1424A 1/06 31  Date/TimeDial-Tone Detection Disable Auto Dial-Tone Detection Digital Dialer Report Enter/Exit Test ModeDisable Call Waiting Touch-tone Dialing Only Disable Call Waiting on 1st AttemptWI1424A 1/06 33  Enable CP-01 Limits Enable TCP/IP CommunicationsEnable Telephone Line Fault Test Exit/Entry FollowerWI1424A 1/06 35  KeyFob Arm/Disarm chirp of Alarm Output Interior Stay BypassKeyFob Control of Relay Groups 1 Keypad Area AssignmentsWI1424A 1/06 37  Power-Up Delay Pre-Dial DelayMemory Failure Never Arm Do not use for primary Burglary protectionWI1424A 1/06 39  Report Digital Dialer Exit Error/Recent Closing Select Alarm Output for Keyfob ChirpRelay Follows Zone Report Telco 1 Report Telco 3 Double or Split ReportingWI1424A 1/06 41  Tamper EZM Tamper Keypad Tamper RF Tamper Wireless Tamper Temperature Display at Keypad Not evaluated by ULSwinger Shutdown WI1424A 1/06 43  Trouble on Open Trouble on Short Not for UL installations Wire, 4-Wire Smoke Detectors See Smoke Detectors Hour Zone WI1424A 1/06 45 Zone Status STANDBY-BATTERY Calculation Worksheet Battery Calculation WorksheetStandby Wiring Legend WI1424A 1/06 47 Function Mode Keypad Programming ModesKeypad Programming Modes Dealer Mode 49 Keypad Programming Modes Easy Menu Mode B456 123 DKeypad Programming Modes User Mode WI1424A 1/06 51 Keypad Configuration Mode Keypad Programming Modes Keypad Configuration ModeWI1424A 1/06 53  Programming AddressLocation Is selected in the Easy Program Menu GEM-P1664 Factory Default Description WI1424A 1/06 55 Out of Box Panel Operation Out of Box Panel Operation Prior to CP-01 Changes FCC Statement WI1424A 1/06 57 Page GEM-P1664 Wiring Diagram GEM-P1664 Wiring Diagram59  Napco Limited Warranty

GEM-P1664 specifications

Napco Security Technologies has long been a leader in the security industry, recognized for its innovative solutions that enhance safety and monitoring capabilities. One of its standout products is the GEM-P1664, a versatile and robust control panel designed for both residential and commercial security applications. This advanced system combines user-friendly features with cutting-edge technology, making it an ideal choice for those looking to bolster their security measures.

The GEM-P1664 boasts a 16-zone configuration, allowing users to monitor multiple areas within a property simultaneously. Each zone can be independently programmed, providing flexibility in how security is managed. This feature is particularly valuable for larger facilities or homes with multiple entry points, as it ensures that all areas are adequately protected. The panel supports both hardwired and wireless zones, delivering versatility to suit various installation preferences.

One of the core technologies integrated into the GEM-P1664 is the use of Event Management and Reporting tools. The panel can automatically log security events, sending alerts via email or SMS in real-time. This capability is essential for maintaining awareness of security status, allowing users to respond promptly to any unauthorized access or unusual activity.

The user interface of the GEM-P1664 is designed with simplicity in mind. Its intuitive layout and navigation make it easy for both trained professionals and everyday users to operate the system without extensive technical knowledge. Additionally, the panel supports multiple user codes, allowing different levels of access for family members or staff, enhancing both security and convenience.

Another notable characteristic of the GEM-P1664 is its compatibility with various Napco peripherals and add-ons, including motion detectors, door/window sensors, and surveillance cameras. This interoperability enables users to create a comprehensive security ecosystem tailored to their specific needs. Furthermore, the GEM-P1664 is also compatible with mobile applications, allowing clients to monitor their security systems remotely via smartphones or tablets.

Lastly, the GEM-P1664 is built with future-proofing in mind. It is designed to be easily upgradable, ensuring that users can incorporate the latest technological advancements and security features as they become available. This forward-thinking approach ensures that the investment in the GEM-P1664 remains relevant and effective over time.

In summary, the Napco Security Technologies GEM-P1664 control panel is a powerful and flexible solution for anyone looking to enhance their security infrastructure. With its robust zone configuration, user-friendly interface, advanced reporting capabilities, and compatibility with a range of devices, the GEM-P1664 stands out as a top choice in the security technology landscape.