and Welcome to the Quadra-Fire Family!
Hearth & Home Technologies welcomes you to our tradition of excellence! In choosing a
This commitment begins with our research of the market, including ‘Voice of the Customer’ contacts, ensuring we make products that will satisfy your needs. Our Research and Development facility then employs the world’s most advanced technology to achieve the optimum operation
of our stoves, inserts and fireplaces. And yet we are old- fashioned when it comes to craftsmanship. Each appliance is meticulously fabricated and gold and nickel surfaces are
We wish you and your family many years of enjoyment in the warmth and comfort of your hearth appliance. Thank you for choosing
SAMPLE OF SERIAL NUMBER / SAFETY LABEL
LOCATION: HANGING ON A CHAIN ON BACK OF APPLIANCE
|
| Portland |
|
|
|
|
|
|
|
| SERIAL NO. | ||||
|
|
|
| MODEL / MODÈLE: TOPAZ |
| ||||||||||
|
|
|
|
|
|
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
|
|
|
| 1445 North HIghway | ||
|
|
|
| VENTED GAS FIREPLACE HEATER FOURNAISE AU GAZ AVEC |
|
| |||||||||
|
|
|
|
|
|
|
| Colville, WA 99114 | |||||||
|
| Report No. / Rapport Numéro | VENTILATION. NOT FOR USE WITH SOLID FUEL / NE PAS UTILISER |
|
|
| www.quadrafire.com | ||||||||
|
|
|
| AVEC LE COMBUSTIBLE SOLIDE. |
|
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
| ||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
|
| |||||
|
| APPROVED FOR CANADA AND USA TO: |
|
|
|
| APPROUVÉ POUR LE CANADA ET LES | ||||||||
|
| ANSI |
| ANSI | |||||||||||
|
| applicable sections of UL307b Gas Burning Heating Appliances for |
| et les sections applicable de UL 307b Appareils de Chauffage Au Gaz pour | |||||||||||
|
| Manufactured Homes and Recreational Vehicles, CAN/CGA |
| les Maisons Mobiles et les Véhicules Motorisés, CAN/CGA | |||||||||||
|
| “Gas Fired Appliances for use at High Altitudes.” This appliance is |
| Fired Appliances for use at High Altitudes”. | |||||||||||
|
| manufactured for operation with Natural Gas. |
|
|
| Cet appareil est manufacturé pour l’opération avec le Gaz Naturel. | |||||||||
|
|
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
| ||||||
|
| FAN TYPE VENTED CIRCULATOR / VENTILATEUR CIRCULATOIRE |
| Thermal Efficiency / Efficacité Thermique* | 85% NG (blower on / avec ventilateur allumé) |
| |||||||||
|
| Blower Electrical Rating / Évaluation du Ventilateur Électrique: |
|
|
|
|
|
| 85% LP (blower on / avec ventilateur allumé) |
| |||||
|
|
|
|
| * With Maximum horizontal length. / Avec longueur horizontale maximum. |
| |||||||||
|
| 115 V., 1.5 Amps, 60 Hz, 150 Watts |
|
|
|
|
| ||||||||
|
|
|
|
|
|
| |||||||||
|
|
|
|
|
|
|
|
|
| ||||||
|
|
|
| For use with Natural Gas | For use with Propane |
|
|
|
|
|
| ||||
Top Vent/Rear Vent: |
| Usage au Gaz Naturel | Usage au Gaz Propane | Bouche Supérieure/Conduit postérieur: | |||||||||||
|
|
| |||||||||||||
Input Rate on “HI” (BTU/Hr) |
|
| 39,500 | 38,000 | Puissance Évaluée à “HI” (BTU/Hr) | ||||||||||
Input Rate on “LO” (BTU/Hr) |
|
| 26,500 | 30,500 | Puissance Évaluée à “LO” (BTU/Hr) | ||||||||||
Maximum Output (BTU/Hr)** |
|
| 33,600 | 32,500 | Puissance Maximum (BTU/Hr)** | ||||||||||
Main Burner Orifice (DMS) |
|
| .125” |
| .073” (49DMS) | Orifice du Brûleur Principal | |||||||||
Minimum Inlet Pressure (Inches W.C.) | 4.5“ |
|
| 11“ | Pression Minimum de la Valve (pouces W.C.) | ||||||||||
Maximum Inlet Pressure (Inches W.C.) | 7.0” |
|
| 14” |
| ression Maximum de la Valve (pouces W.C.) | |||||||||
Manifold Pressure on “HI” (Inches W.C.) | 3.5” |
|
| 10” |
| ression du Collecteur d’ Échappement à “HI” (pouces W.C.) | |||||||||
**Max Venting, Blower On |
|
|
|
|
|
|
| ** Ventilation Maximum, Ventilateur Allumé |
This appliance equipped only for altitudes
This appliance must be installed in accordance with local codes, if any (and Commonwealth of Massachusetts approved); if none, follow National Fuel Gas Code ANSI Z223.1, or Canadian Installation Codes,
Cet appareil est équipé pour les altitudes de
This appliance must be installed in accordance with the current Standard C N/CSA Z240 MH, Mobile Housing or with Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280, or when such standard is not applicable, NSI/NCSBCS A225.1/NFPA 501A, Manufactured Home Installation Standard.
WARNING: Do not operate the appliance until all sections have been assembled and installed in accordance with the manufacturer's instructions.
Installer l'appareil selon la norme CAN/C | érie MM, Maisons mobiles ou la norme 24 CFR Part 3280, Manufactured Home Construction and Safety Standard. Si ces |
normes ne sont pas pertinentes, utilisez la norme | N I/NC BCS 225.1/NFPA 501A, Manufactured Home Installations Standard. |
AVERTISSEMENT: Ne pas utiliser l'appareil tant que toutes les sections n'ont pas ete assemblees et installees selon les instructions du fabricant.
This appliance must be properly connected to a venting system in accordance with the manufacturer's installation instructions.
Cet apprareil doit être correctement raccordé à un système d'évacuation, conformément aux instructions du fabricant
| F |
|
|
|
| G |
|
|
| C |
|
|
| A | A |
| B | D |
|
|
| E |
|
A | A | C |
|
A. | Side of stove top to side wall | 6.5" (152 mm) |
|
| Du coté du poêle au | coté | du mur |
B. | Rear of stove top to back wall | 6" (100 mm) |
|
| Le contrôle arrière au mur arrière | ||
C. | Corner of stove top to side wall | 1" (152 mm) |
|
| Du Coin du poêle du mur | ||
D. | Minimum Alcove Height | 54" (1372 mm) | Hauteur minimum du plancher au plafond | ||||
E. | Maximum Alcove Depth | 36" (914 mm) |
|
| Profondeur maximale de l'alcôve | ||
F. | Minimum Alcove Width | 40"(915 mm) |
|
| Largeur minimum de l'alÔve | ||
G. Mantle clearance from stove top | 23"(584mm) |
| Espace libre du poêle au manteau |
HEARTH: A
CHEMINÉE: Un coussinet
Date of Manufacture / Date du Manufacturier
2008 2009 2010 Jan Feb Mar Apr May | Jun | Jul | Aug Sep Oct | Nov Dec |
DO NOT REMOVE THIS LABEL / NE PAS ENLEVER L’ÉTIQUETTE | Made in U.S.A. / Fait Aux |
Serial Number
Barcode
Model Name
Test Lab & Report No.
Manufactured Date
2 |