Figure 8.16 Install left or right side panel. Place in lower chan- nel and rotate into place.
NOTE: Side brick panels will fit only if installed at an angle. Do not attempt to push the brick flat against the outer wall of the firebox. Brick should rest against spacer on inside of firebox.
Figure 8.17 Bend over tabs to hold panel in place.
Install the top panel/baffle. If rear venting, set damper prior to installing the top panel/baffle. (In the Commonwealth of Massachusetts, the word damper shall be replaced with the word damper shall be replaced with the words flue restrictor.) The back edge will slide in front of the rear brick panel. Rest one end of the top panel/baffle on the installed side panel and support the other end with one hand.
Install the remaining side panel and bend over the tabs to hold it in place. Rest top panel/baffle on sides and slide top panel/baffle left or right until centered.
Figure 8.18 Fully installed brick set. Note that with the brick installed the firebox is narrower at the back than in the front.
G. Positioning the Logs
While still breakable, the logs do not become fragile until after the appliance is burned and they have cured. After curing, any handling must be done with care as breakage can easily occur.
PLEASE NOTE: Logs have been designed to work specifically with the burner of this appliance. Exact placement will ensure proper operation of your gas appliance and reduce sooting.
1 4
5
23
Figure 8.19 The log set is packed in the components box and consists of the following:
Qty. | Description | # |
1 | Rear Log | 1 |
1 | Left Front Log | 2 |
1 | Right Front Log | 3 |
1 | Left Twig | 4 |
1 | Right Twig | 5 |