OmniTek 839-1340, 839-1290, 839-1320 owner manual Positioning the Logs, Qty Description

Page 32

Figure 8.16 Install left or right side panel. Place in lower chan- nel and rotate into place.

NOTE: Side brick panels will fit only if installed at an angle. Do not attempt to push the brick flat against the outer wall of the firebox. Brick should rest against spacer on inside of firebox.

Figure 8.17 Bend over tabs to hold panel in place.

Install the top panel/baffle. If rear venting, set damper prior to installing the top panel/baffle. (In the Commonwealth of Massachusetts, the word damper shall be replaced with the word damper shall be replaced with the words flue restrictor.) The back edge will slide in front of the rear brick panel. Rest one end of the top panel/baffle on the installed side panel and support the other end with one hand.

Install the remaining side panel and bend over the tabs to hold it in place. Rest top panel/baffle on sides and slide top panel/baffle left or right until centered.

Figure 8.18 Fully installed brick set. Note that with the brick installed the firebox is narrower at the back than in the front.

G. Positioning the Logs

While still breakable, the logs do not become fragile until after the appliance is burned and they have cured. After curing, any handling must be done with care as breakage can easily occur.

PLEASE NOTE: Logs have been designed to work specifically with the burner of this appliance. Exact placement will ensure proper operation of your gas appliance and reduce sooting.

1 4

5

23

Figure 8.19 The log set is packed in the components box and consists of the following:

Qty.

Description

#

1

Rear Log

1

1

Left Front Log

2

1

Right Front Log

3

1

Left Twig

4

1

Right Twig

5

32

Quadra-Fire • Topaz • 7009-113 Rev. J • 12/11

Image 32
Contents Do Discardnot Hot glass will cause burnsWelcome to the Quadra-Fire Family Table of Contents 1Listing and Code Approvals Requirements for the Commonwealth of Massachusetts Manufacturer RequirementsGas Equipment Venting System Provided Gas Equipment Venting System not ProvidedDesign & Installation Considerations Getting StartedInspect Appliance & Components Tools and Supplies NeededDesign Purposes only Selecting Appliance LocationClearances 4Termination Locations Vent Termination Minimum ClearancesAlcove Applications Vent Information Venting ComponentsUse of Elbows Measuring StandardsHow to Use the Vent Graph Venting GuidelinesVertical Distance From Appliance toType a Up & Out Installations for Top Vent Configurations Type B Rear Installations for Use with Rear Vent KitHorizontal Termination StepTop Vent Touching the hot cap Step Vertical TerminationDirect Vent Pipe Ceiling Joists Framing 2 in mm Long Wood Screws Twist-lock the vent cap and seal Cathedral Ceiling Class a Metal Chimney Existing Masonry Chimney Fire Risk Explosion Risk Retro Connector Converting to LP Gas Gas InformationFuel Conversions Valve Regulator Replacement Propane Natural GASGas Pressures PressureGas Connection Check for GAS LeaksRecommendation for Wire Connecting to the ApplianceStanding Pilot Ignition System Wiring Wire Size Max. LengthSwitch Red 28 Thermocouple Gas Pilot Ignitor ThermopileIgnitor Red 28 711mm ON/OFFTop to Rear Vent Conversion Appliance SetupRemove Shipping Materials Accessories Leg Leveling SystemFor Both Quartet and Solitaire Fronts Front Installation Fronts shipped attached to faceBrick Installation Positioning the Logs Qty DescriptionMineral Wool Glass Door Assembly Replacement Blower InstallationWhite Damper Adjustment Shutter AdjustmentFor TOP or Rear Vent Installations Make adjustmentControls Operating InstructionsBefore Lighting Appliance For Your Safety Read Before Lighting Lighting ApplianceAfter Appliance is Lit Frequently Asked QuestionsInitial Break-in Procedure Troubleshooting Symptom Possible Cause Corrective ActionBe Placed in this Opening Maintaining and Servicing Your Appliance After servicingMaintenance Tasks Inspect Necessary. USE Caution When CLEANING/HANDLING Ceramic BurnerAppliance Dimension Diagram Reference MaterialsVent Components Diagram Mm inner pipe 6-5/8 in mm outer pipeVent Components List DescriptionSimpson Dura-VentHHT SLP SimpsonDescription Dura-Vent Termination Caps & KitsDirect Vent Gas Stove RD. Service Parts ListLog Set Assembly Part number list on following Service Parts List StockedAt Depot Description Comments Part NumberSIDE-TPZ-POR BRNR-TOPAZSIDE-TPZ-MBK TOUCHUP-CSB TOUCHUP-CWLStocked Description Comments Part Number Accessories BK-GASWSLG-CSB FastenersLimited Lifetime Warranty Limited Lifetime WarrantyWarranty Conditions Dealer Telephone TopazContact Information