OmniTek 839-1320, 839-1290, 839-1340 owner manual Retro Connector

Page 22

Flex Liner

Flex Coupler

Sheet Metal Screws

6 in. (152mm) diameter opening in masonry wall

Figure 5.27

Figure 5.29

Retro Connector

(3) Masonry Bolts (Not included)

Step 8.

Secure the top adapter to the flashing. Use three sheet metal screws through the side of the top adapter into the flange on the flashing (Figure 5.28). Twist lock the high wind termination cap on to the top adapter.

High Wind

Termination Cap

Top Adaptor

(3) Sheet Metal Screws

Flashing

Figure 5.28

Step 10.

Slide wall thimble cover over retro connector and secure with masonry bolts (Figure 5.30). If you have a framed wall in front of the masonry, use wood screws to mount wall thimble cover to framed wall, over retro connector and 10 in. (254mm) square framed opening (Figure 5.25, on page 21). If needed, add a section of direct vent pipe to the retro connector in order to extend through the opening in the wall thimble cover.

Retro Connector

Wall Thimble Cover

(4)Masonry Bolts (Not included)

Figure 5.30

Step 9.

Attach the flex to the retro connector. Use three sheet metal screws to attach the flex liner to the connector (Figure 5.29). Mount the retro connector to the masonry wall using masonry bolts. Redrill larger holes on connector as needed. Be careful to ensure that the connector is centered in the opening and the mounting holes line up with the masonry wall.

Step 11.

The connection between the appliance and the retro connector may be completed with sections of direct vent pipe.

22

Quadra-Fire • Topaz • 7009-113 Rev. J • 12/11

Image 22
Contents Do Discardnot Hot glass will cause burnsWelcome to the Quadra-Fire Family Table of Contents 1Listing and Code Approvals Gas Equipment Venting System Provided Requirements for the Commonwealth of MassachusettsManufacturer Requirements Gas Equipment Venting System not ProvidedInspect Appliance & Components Design & Installation ConsiderationsGetting Started Tools and Supplies NeededClearances Selecting Appliance LocationDesign Purposes only 4Termination Locations Vent Termination Minimum ClearancesAlcove Applications Use of Elbows Vent InformationVenting Components Measuring StandardsVertical Distance How to Use the Vent GraphVenting Guidelines From Appliance toHorizontal Termination Type a Up & Out Installations for Top Vent ConfigurationsType B Rear Installations for Use with Rear Vent Kit StepTop Vent Touching the hot cap Direct Vent Pipe Vertical TerminationStep Ceiling Joists Framing 2 in mm Long Wood Screws Twist-lock the vent cap and seal Cathedral Ceiling Class a Metal Chimney Existing Masonry Chimney Fire Risk Explosion Risk Retro Connector Fuel Conversions Gas InformationConverting to LP Gas Valve Regulator Replacement Propane Natural GASGas Pressures PressureGas Connection Check for GAS LeaksStanding Pilot Ignition System Wiring Recommendation for WireConnecting to the Appliance Wire Size Max. LengthIgnitor Red 28 711mm Switch Red 28Thermocouple Gas Pilot Ignitor Thermopile ON/OFFRemove Shipping Materials Appliance SetupTop to Rear Vent Conversion Accessories Leg Leveling SystemBrick Installation Front Installation Fronts shipped attached to faceFor Both Quartet and Solitaire Fronts Positioning the Logs Qty DescriptionMineral Wool Glass Door Assembly Replacement Blower InstallationWhite For TOP or Rear Vent Installations Damper AdjustmentShutter Adjustment Make adjustmentBefore Lighting Appliance Operating InstructionsControls For Your Safety Read Before Lighting Lighting ApplianceInitial Break-in Procedure Frequently Asked QuestionsAfter Appliance is Lit Troubleshooting Symptom Possible Cause Corrective ActionBe Placed in this Opening Maintaining and Servicing Your Appliance After servicingMaintenance Tasks Inspect Necessary. USE Caution When CLEANING/HANDLING Ceramic BurnerAppliance Dimension Diagram Reference MaterialsVent Components Diagram Mm inner pipe 6-5/8 in mm outer pipeSimpson Vent Components ListDescription Dura-VentDescription Dura-Vent HHT SLPSimpson Termination Caps & KitsLog Set Assembly Part number list on following RD. Service Parts ListDirect Vent Gas Stove At Depot Service Parts ListStocked Description Comments Part NumberSIDE-TPZ-MBK BRNR-TOPAZSIDE-TPZ-POR TOUCHUP-CSB TOUCHUP-CWLStocked WSLG-CSB Description Comments Part Number AccessoriesBK-GAS FastenersLimited Lifetime Warranty Limited Lifetime WarrantyWarranty Conditions Contact Information TopazDealer Telephone