Figure 6.6 Pull off pilot hood and set it aside.
NOTE: Do not remove the retaining clip from the hood.
Figure 6.7 Use a 5/32 in. Allen wrench to remove the pilot injector.
Replace pilot injector with the one supplied with the appli- ance (#35 for Propane, #62 for Natural Gas).
Replace pilot hood, snapping it into position, making sure notch and tab line up.
Reinstall burner by placing it into the firebox. Make sure to reinstall all the screws previously removed.
Reinstall logs, glass and front. |
|
PROPANE | NATURAL GAS |
.073 (49 DMS) | .0125 (1/8 in.) |
2. Valve Regulator Replacement
WARNING
Fire Risk.
Explosion Risk.
•Disconnect any electrical cords and turn off gas supply to unit before proceeding if converting fuel on an appliance already fully installed.
Remove upper and lower back shield. Loosen the set col- lars on the extension rods with the 3/32 in. Allen wrench. Remove the rods and adapter cap.
A Mounting Screws
B Pressure Regulator Tower
C Diaphragm
Figure 6.8 Turn control knob to the OFF position, ensure that gas supply to the valve has been turned off. Using a Torx TH20, or slotted screwdriver, remove the three pressure reg- ulator mounting screws (A), pressure regulator tower (B), and diaphragm (C).
24 |