OmniTek 839-1320, 839-1290, 839-1340 Vent Components List, Description, Simpson, Dura-Vent

Page 46

C. Vent Components List

Description

HHT SLP

Simpson

 

M= Multi Pack (6)

Dura-Vent ®

 

 

DirectVent Pro

4” Pipe Length, Galvanized

SLP4M

-

4” Pipe Length, Black

SLP4-BK

-

 

 

 

6” Pipe Length, Galvanized

SLP6M

46-DVA-06

 

 

 

6” Pipe Length, Black

SLP6-BK

46-DVA-06B

9” Pipe Length, Galvanized

-

46-DVA-09

 

 

 

9” Pipe Length, Black

-

46-DVA-09B

12” Pipe Length, Galvanized

SLP12M

46-DVA-12

 

 

 

12” Pipe Length, Black

SLP12-BK

46-DVA-12B

 

 

 

18” Pipe Length, Galvanized

-

46-DVA-18

18” Pipe Length, Black

-

46-DVA-18B

 

 

 

24” Pipe Length, Galvanized

SLP24M

46-DVA-24

 

 

 

24” Pipe Length, Black

SLP24-BK

46-DVA-24B

36” Pipe Length, Galvanized

SLP36M

46-DVA-36

 

 

 

36” Pipe Length, Black

SLP36-BK

46-DVA-36B

 

 

 

48” Pipe Length, Galvanized

SLP48M

46-DVA-48

48” Pipe Length, Black

SLP48-BK

46-DVA-48B

 

 

 

Adjustable Length, 3”-6”, Black

SLP6A-BK

-

Adjustable Length, 3”-6”, Galvanized

SLP6AM

-

 

 

 

Adjustable Length, 3”-7”, Galvanized

-

46DVA-08A

 

 

 

Adjustable Length, 3”-7”, Black

-

46DVA-08AB

Adjustable Length, 3”-12”, Black

SLP12A-BK

-

 

 

 

Adjustable Length, 3”-12”, Galvanized

SLP12AM

-

Adjustable Length, 3”-14.5”, Galvanized

-

46DVA-16A

 

 

 

Adjustable Length, 3”-14.5”, Black

-

46DVA-16AB

 

 

 

Adjustable Length, 16”, Galvanized

-

46DVA-16A

Adjustable Length, 16”, Black

-

46DVA-16AB

 

 

 

2’ Flexible Pipe Length

SLP-FLEX-2

-

3’ Flexible Pipe Length

SLP-FLEX-3

-

 

 

 

5’ Flexible Pipe Length

SLP-FLEX-5

-

 

 

 

10’ Flexible Pipe Length

SLP-FLEX-10

-

3” x 35’ Flex Extension

-

2280

 

 

 

4” x 35’ Flex Extension

-

2281

45° Elbow, Galvanized

SLP45M

-

 

 

 

45° Elbow, Black

SLP45-BK

See Swivel

 

 

 

45° Elbow, Swivel, Galvanized

-

46DVA-E45

45° Elbow, Swivel, Black

-

46DVA-E45B

 

 

 

46

Quadra-Fire • Topaz • 7009-113 Rev. J • 12/11

Image 46
Contents Do Discardnot Hot glass will cause burnsWelcome to the Quadra-Fire Family Table of Contents 1Listing and Code Approvals Gas Equipment Venting System Provided Requirements for the Commonwealth of MassachusettsManufacturer Requirements Gas Equipment Venting System not ProvidedInspect Appliance & Components Design & Installation ConsiderationsGetting Started Tools and Supplies NeededClearances Selecting Appliance LocationDesign Purposes only 4Termination Locations Vent Termination Minimum ClearancesAlcove Applications Use of Elbows Vent InformationVenting Components Measuring StandardsVertical Distance How to Use the Vent GraphVenting Guidelines From Appliance toHorizontal Termination Type a Up & Out Installations for Top Vent ConfigurationsType B Rear Installations for Use with Rear Vent Kit StepTop Vent Touching the hot cap Direct Vent Pipe Vertical TerminationStep Ceiling Joists Framing 2 in mm Long Wood Screws Twist-lock the vent cap and seal Cathedral Ceiling Class a Metal Chimney Existing Masonry Chimney Fire Risk Explosion Risk Retro Connector Fuel Conversions Gas InformationConverting to LP Gas Valve Regulator Replacement Propane Natural GASGas Pressures PressureGas Connection Check for GAS LeaksStanding Pilot Ignition System Wiring Recommendation for WireConnecting to the Appliance Wire Size Max. LengthIgnitor Red 28 711mm Switch Red 28Thermocouple Gas Pilot Ignitor Thermopile ON/OFFRemove Shipping Materials Appliance SetupTop to Rear Vent Conversion Accessories Leg Leveling SystemBrick Installation Front Installation Fronts shipped attached to faceFor Both Quartet and Solitaire Fronts Positioning the Logs Qty DescriptionMineral Wool Glass Door Assembly Replacement Blower InstallationWhite For TOP or Rear Vent Installations Damper AdjustmentShutter Adjustment Make adjustmentBefore Lighting Appliance Operating InstructionsControls For Your Safety Read Before Lighting Lighting ApplianceInitial Break-in Procedure Frequently Asked QuestionsAfter Appliance is Lit Troubleshooting Symptom Possible Cause Corrective ActionBe Placed in this Opening Maintaining and Servicing Your Appliance After servicingMaintenance Tasks Inspect Necessary. USE Caution When CLEANING/HANDLING Ceramic BurnerAppliance Dimension Diagram Reference MaterialsVent Components Diagram Mm inner pipe 6-5/8 in mm outer pipeSimpson Vent Components ListDescription Dura-VentDescription Dura-Vent HHT SLPSimpson Termination Caps & KitsLog Set Assembly Part number list on following RD. Service Parts ListDirect Vent Gas Stove At Depot Service Parts ListStocked Description Comments Part NumberSIDE-TPZ-MBK BRNR-TOPAZSIDE-TPZ-POR TOUCHUP-CSB TOUCHUP-CWLStocked WSLG-CSB Description Comments Part Number AccessoriesBK-GAS FastenersLimited Lifetime Warranty Limited Lifetime WarrantyWarranty Conditions Contact Information TopazDealer Telephone