Monessen Hearth ILDV20PV, ILDV20NV, ILDV30NV manual Lighting pilot, Approved leak testing method

Page 26

 

 

 

ILDV20/ILDV30 Fireplace Insert

OPERATING INSTRUCTIONS

 

 

 

Lighting pilot for the first time

approved leak testing method

You may check for gas leaks with the following meth- ods only:

Soap and water solution

An approved leak testing spray

Electronic sniffer

WARNING

If using a soap and water solution to test for leaks, DO NOT spray solution onto control body.

danger

Never check for gas leak with open flame!

NOTE: Remove any excessive pipe compound from the connections. Excessive pipe compound can set off electronic sniffers.

Check for gas leaks in each of the following locations:

Pipe from the gas supply line connection to the gas valve

Burner connections

• Field made joints / gas shutoff valve

Pilot

Factory made joints

Each joint or connection

All joints on valve and control body

WARNING

Lighting pilot

The control has an interlock device that does not allow the lighting of the fireplace up to the moment the safety device of the flame has not interrupted the gas flow. After that period of time (when the magnet is closed), it is possible to start the lighting operation.

The gas control knob is designed to be operated by hand. DO NOT use any tools during this operation. Damaged knobs may result in serious injury.

1.Depress and turn knob counterclockwise to pilot position.

2.Depress fully and hold pilot gas knob. Depress piezoigniterasmanytimesasneededtoignitepilot. Keep knob fully depressed for a few seconds. Release and check that pilot continues to burn.

If the pilot does not stay lit,

WARNING

If the knob does not "pop"

out to its original position

repeat steps 1 and 2.

when released, turn off gas

 

 

to appliance and contact

 

qualified service technician.

 

 

 

 

O

T

N

O

 

L

 

I

 

P

 

 

F

 

F

 

O

PILOT

Figure 26 - Pilot Position

Continued on next page

26

83D0511

Image 26
Contents Ildv Series Direct Vent Gas Fireplace Insert What to do if YOU Smell GASVent Installation General Installation InformationInstallation Insert InstallationOwner Important Safety InformationInstaller Gas is commonly known as Never connect unit to privateNon-utility gas wells. This Wellhead gasListed Vented GAS Fireplace Heater Product features and code approvalProduct Specifications Before You Start High ElevationsOrifice SIZES, Pressures and BTUs ILDV20NV ILDV20PV ILDV30NV ILDV30PVInsert dimensions ILDV20 ILDV30General installation Information Insert ApplicationsMantel clearances ClearancesInsert Clearances Hearth RequirementsInsert Placement Installation ZERO-CLEARANCE Metal Fireplace RequirementsVent installation Installation PrecautionsVent Requirements Dealer or installer if you suspect an improperly adjusted Failure to adjust air shutter properly may lead to improperCombustion which can create a safety hazard. Consult your Altitude ConsiderationsVent Configurations Manifold Removal and Installation Remove Manifold and Attach to Flex VentInsert Installation Check gas typeTo liquid petroleum LP gas Insert installationUse pipe joint sealant that is resistant Check for gas leaks Check GAS PressureDo not use open flame to Remote Wall mounted Switch Hand Held Remote ControlDo not use the entire bag of rock wool to cover burner area Log placementInstalling Logs and Rock Wool Ember Material in Firebox Place Log #6 Place Log #5 Surround installation Install SurroundInitial lighting Operating InstructionsWhat to do if YOU Smell GAS Never use an open flame to check for gas leakApproved leak testing method Lighting pilotPilot position Main burner switchLighting the burner Adjust the AIR Shutter Glass Frame Removal Glass Frame RemovalBlower Replacement Blower Parts List 20ILDV 30ILDVCleaning and Maintenance Cleaning glassRelight pilot. Refer to Maintenance Replacement Parts Replacement Parts Troubleshooting Observed Problem Possible Cause RemedyILDV20/ILDV30 Fireplace Insert Basic Warranty Lifetime WarrantyFive Year Warranty If Warranty Service is NeededMhsc AFUE%