3.1VENTING LENGTHS AND COMPONENTS

Use only Wolf Steel, Simpson Dura-Vent, Selkirk Direct Temp, American Metal Amerivent or Metal-Fab venting components. Minimum and maximum vent lengths, for both horizontal and vertical installations, and air terminal locations for either system are set out in this manual and must be adhered to. For Simpson Dura-Vent, Selkirk Direct Temp, American Metal Amerivent and Metal-Fab follow the installation procedure provided with the venting components.

A starter adaptor must be used with the following vent systems and may be purchased from the corresponding supplier:

PART

4”/7”

SUPPLIER

WEBSITE

 

 

 

 

Duravent

GDS924N

Wolf Steel

www.duravent.com

 

 

 

 

Amerivent

4DSC-N2

American Metal

www.americanmetalproducts.com

 

 

 

 

Direct Temp

4DT-AAN

Selkirk

www.selkirkcorp.com

 

 

 

 

SuperSeal

4DNA

Metal-Fab

www.mtlfab.com

 

 

 

 

*For Simpson Dura-Vent, Selkirk Direct Temp, American Metal Amerivent and Metal-Fab follow the installation procedure found on the website for your venting supplier.

For vent systems that provide seals on the inner exhaust flue, only the outer air intake joints must be sealed using a red high temperature silicone (RTV). This same sealant may be used on both the inner exhaust and outer intake vent pipe joints of all other approved vent systems except for the exhaust vent pipe connection to the appliance flue collar which must be sealed using the black high temperature sealant Mill Pac.

When using Wolf Steel venting components, use only approved Wolf Steel termination kits: wall terminal kit GD175 (7/12’ of venting included), or 1/12 to 7/12 pitch roof terminal kit GD110, 8/12 to 12/12 roof terminal kit GD111, flat roof terminal kit GD112 or periscope kit GD180 (for wall penetration below grade) in conjunction with the appropriate venting components.

For optimum flame appearance and appliance operation, keep the vent length and number of elbows to a minimum. It is recommended that all horizontal runs have a minimum 1/4” rise per foot. The air terminal must remain unobstructed at all times. Examine the air terminal at least once a year to verify that it is unobstructed and undamaged. Rigid and flexible venting systems must not be combined. Different venting manufacturers components must not be combined.

These vent kits allow for either horizontal or vertical venting of the appliance. The maximum allowable horizontal run is 20 feet. The maximum allowable vertical vent length is 40 feet. The maximum number of vent connections is two horizontally or three vertically (excluding the appliance and the air terminal connections) when using flexible venting.

Deviation from the minimum vertical vent length can create difficulty in burner start-up and/or carboning. Use an adjustable pipe as the final length of rigid piping to the stove for ease of installation.

8.5

W415-0788 / A / 09.22.09

Image 10
Contents GDS60N & GS60N Table of Contents Installation Overview InstallationIntroduction Dimensions General InstructionsWe suggest that our gas General InformationRating Plate Model Natural GAS/GAZ NaturalGlass Door Removal Care of GlassShipping Bracket Shippingbracket LatchRefer to the section applicable to your installation Venting Model GDS60Venting Lengths and Components Part Supplier WebsiteMinimum Feet Maximum Typical Vent InstallationsTOP Vent Minimum Feet Maximum Rear Vent Rise PlusMinimum Plus Rise Grade Special Vent Installations 3.3.1 Periscope TerminationCorner Termination To Grade MinimumInstallations Canada Vent Terminal ClearancesVenting Application Flow Chart TOP Exit Rear ExitElbow Vent Length Values DefinitionsFeet Inches TOP Exit Horizontal Termination HT VTFormula 1 HT VT Formula 2 HT + VT 40 FT Rear Exit Horizontal Termination Horizontal Vent RUN Plus Offset in Feet HT10c TOP or Rear Exit Vertical Termination 11a11c Orifice Replacement Installation Preparation Model GDS60Rear Vent Termination Changing a TOP Vent to a Rear Vent Minimum Clearance to Combustibles InstallationMaintain These Minimum Clearances to Combustibles Horizontal Installation Wall and Ceiling ProtectionVertical Installation Horizontal AIR Terminal Installation Model GDS60Roof Support Vertical AIR Terminal Installation Model GDS60High Temperature Sealant Inner Flex Pipe Inner PipeHigh Temperature Sealant Mobile Home Installation Model GDS60GAS Installation Appliance Vent Connection Model GDS60Vent Specifics Model GS60 5.7.1 Chimney Installation Optional Wall Switch / ThermostatWire Size MAX. Length Installing B Vent Combustion AIRAdding Vent Sections More MIN Flat Roof WallInstalling Flashing and Storm Collar Caulking Storm Collar Weather Sealant FlashingFront Cast Removal Glass Door Installation and RemovalFinishing Return FlangeGlass / Door Replacement LOG PlacementLogo Placement Switch and Bracket Installation Access Cover PlateOptional Blower Installation Slot Removed ScrewsWiring Diagram Operating Instructions OperationModel GS60 only Venting Action Check Anti Condensation Switch Lighting InstructionsVenturi Adjustment AdjustmentPilot Burner Adjustment Flame CharacteristicsMaintenance Replacements Common ComponentsGS60 Components Roof Terminal Kits 49 50 Trouble Shooting Symptom ProblemSymptom Problem Test Solution Glass Embers only HOTGDS600 only GS600 onlyWarranty Conditions and LimitationsService History Appliance Service History