5.7.5 ADDING VENT SECTIONS
Add chimney sections, according to the manufacturers installation instructions. For ease of assembly, a 7” telescoping pipe may be installed over the 4” vent connection of the adapter. Add vent sections, twist locking (clockwise) securely, to the required height. The chimney must extend at least, 3 feet above its point of contact with the roof and at least 2 feet higher than any wall, roof or building within 10 feet horizontally.
|