Napoleon Fireplaces GDS60N manual TOP or Rear Exit Vertical Termination, 11a

Page 21

21

3.11 TOP OR REAR EXIT VERTICAL TERMINATION

(HT) < (VT)

Simple venting configurations.

See graph to determine the required vertical rise VT for the

 

required horizontal run HT.

REQUIRED

VERTICAL

RISE IN

FEET VT

FIGURE 3.11a

40

 

 

 

 

30

 

 

 

 

20

 

 

 

 

10

 

 

 

 

3

 

 

 

 

0

5

10

15

20

 

 

 

 

HORIZONTAL VENT RUN PLUS OFFSET IN FEET HT

 

 

 

 

The shaded area within the lines represents acceptable

 

 

 

 

 

values for HT and HT

 

For vent configurations requiring one or more 90° elbows (top exit) or one or more 90° elbows (rear exit),

the following formulas apply:

 

 

 

Formula 1: HT

< VT

 

 

 

Formula 2: HT

+ VT < 40 feet

 

 

 

Example 6:

 

 

90°

 

V1

= 5 FT

 

 

V3

 

 

 

V2

= 6 FT

 

 

 

 

 

90°

 

V3

= 10 FT

 

 

 

VT

= V1

+ V2 + V3 = 5 + 6 + 10 = 21 FT

 

H

2

H1

= 8 FT

 

 

V2

H2

= 2.5 FT

 

FIGURE 3.11b

H1

90°

HR

= H1

+ H2 = 8 + 2.5 = 10.5 FT

V1

 

 

 

HO

= .03 (four 90° elbows - 90°)

 

90°

 

= .03 (360° - 90°) = 8.1 FT

 

HT

= HR

+ HO = 10.5 + 8.1 = 18.6 FT

 

 

 

HT

+ VT

= 18.6 + 21 = 39.6 FT

 

 

 

Formula 1:

HT

< 3.5 VT

 

18.6 < 21

Formula 2:

HT

+ VT < 40 FT

 

39.6 < 40

Since both formulas are met, this vent configuration is acceptable.

18.2

W415-0788 / A / 09.22.09

Image 21
Contents GDS60N & GS60N Table of Contents Installation Installation OverviewIntroduction General Instructions DimensionsGeneral Information We suggest that our gasModel Natural GAS/GAZ Natural Rating PlateShipping Bracket Care of GlassGlass Door Removal Shippingbracket LatchVenting Model GDS60 Refer to the section applicable to your installationPart Supplier Website Venting Lengths and ComponentsTypical Vent Installations Minimum Feet MaximumTOP Vent Minimum Feet Maximum Rear Vent Plus RiseMinimum Plus Rise Corner Termination Special Vent Installations 3.3.1 Periscope TerminationGrade To Grade MinimumVent Terminal Clearances Installations CanadaRear Exit Venting Application Flow Chart TOP ExitDefinitions Elbow Vent Length ValuesFeet Inches HT VT TOP Exit Horizontal TerminationFormula 1 HT VT Formula 2 HT + VT 40 FT Horizontal Vent RUN Plus Offset in Feet HT Rear Exit Horizontal Termination10c 11a TOP or Rear Exit Vertical Termination11c Installation Preparation Model GDS60 Orifice ReplacementRear Vent Termination Changing a TOP Vent to a Rear Vent Installation Minimum Clearance to CombustiblesMaintain These Minimum Clearances to Combustibles Wall and Ceiling Protection Horizontal InstallationHorizontal AIR Terminal Installation Model GDS60 Vertical InstallationHigh Temperature Sealant Inner Flex Pipe Vertical AIR Terminal Installation Model GDS60Roof Support Inner PipeGAS Installation Mobile Home Installation Model GDS60High Temperature Sealant Appliance Vent Connection Model GDS60Optional Wall Switch / Thermostat Vent Specifics Model GS60 5.7.1 Chimney InstallationWire Size MAX. Length Combustion AIR Installing B VentMore MIN Flat Roof Wall Adding Vent SectionsCaulking Storm Collar Weather Sealant Flashing Installing Flashing and Storm CollarFinishing Glass Door Installation and RemovalFront Cast Removal Return FlangeLOG Placement Glass / Door ReplacementLogo Placement Access Cover Plate Switch and Bracket InstallationSlot Removed Screws Optional Blower InstallationWiring Diagram Operation Operating InstructionsModel GS60 only Venting Action Check Lighting Instructions Anti Condensation SwitchPilot Burner Adjustment AdjustmentVenturi Adjustment Flame CharacteristicsMaintenance Common Components ReplacementsGS60 Components Roof Terminal Kits 49 50 Symptom Problem Trouble ShootingSymptom Problem Test Solution GDS600 only HOTGlass Embers only GS600 onlyConditions and Limitations WarrantyAppliance Service History Service History