Napoleon Fireplaces GDS60N manual Rating Plate, Model Natural GAS/GAZ Natural

Page 7

7

When the appliance is installed at elevations above 4,500ft, and in the absence of specific recommendations from the local authority having jurisdiction, the certified high altitude input rating shall be reduced at the rate of 4% for each ad- ditional 1,000ft.

Change in flame appearance from "HI" to "LO" is more evident in natural gas than in propane.

Expansion / contraction noises during heating up and cooling down cycles are normal and to be expected.

This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases, unless a certified kit is used.

GDS60 - This appliance is not approved for closet or recessed installations. It is approved for bathroom, bed- room and bedsitting room installations. This appliance may be installed in an aftermarket permanently located, manufactured (mobile) home, where not prohibited by local codes. (Rear vent) This application requires changing the main burner orifice.

GS60 - This appliance is approved for bedroom and bed-sitting room installations.

2.4RATING PLATE

CERTIFIED UNDER: CSA 2.33-2000, ANSI Z21.88-2000 VENTED GAS FIREPLACE HEATER AS A DIRECT VENT

MODEL CDVS600/GDS60 APPROVED FOR BEDROOM, BATHROOM & BEDSIT-

AND CSA2.22-M98,ANSI Z21.50-1998 VENTED GAS FIREPLACE AS A B-VENT. HOMOLOGUE SELON LES

TING ROOM INSTALLATION. SUITABLE FOR MOBILE HOME INSTALLATION IF

NORMES: CSA 2.33-2000, ANSI Z21.88-2000 FOYER DE CHAUFFAGE AU GAZ AVEC EVACUATION EN TANT

INSTALLED IN ACCORDANCE WITH THE CURRENT STANDARD CAN/CSA Z240MH

QU’UNE EVACUATION DIRECTE ET CSA2.22-M98,ANSI Z21.50-1998 FOYER AU GAZ AVEC EVACUATION

SERIES GAS EQUIPPED MOBILE HOMES, IN CANADA OR IN THE UNITED

EN TANT QU’UN EVENT “B”.

STATES THE MANUFACTURED HOME CONTRUCTION AND SAFETY STANDARD,

 

 

 

NOT FOR USE WITH SOLID FUEL

 

 

 

 

 

 

 

 

TITLE 24 CFR, PART 3280. WHEN THIS US STANDARD IS NOT APPLICABLE USE

 

UN COMBUSTIBLE SOLIDE NE DOIT PAS ETRE UTILISE AVEC CET APPAREIL

THE STANDARD FOR FIRE SAFETY CRITERIA FOR MANUFACTURED HOME

 

INSTALLATIONS, SITES AND COMMUNITIES, ANSI/NFPA 501A.

MODEL NATURAL GAS/GAZ NATURAL

 

MODEL PROPANE/PROPANE MODÈLE

HOMOLOGUE POUR INSTALLATION DANS UNE CHAMBRE A COUCHER, UNE

 

SALLE DE BAIN ET UN STUDIO. APPROPRIE POUR INSTALLATION DANS UNE

DIRECT VENT

B-VENT

 

 

B-VENT

DIRECT VENT

MAISON MOBILE SI SON INSTALLATION CONFORME AUX EXIGENCES DE LA

GDS60N

GS60N

 

 

GS60P

 

 

 

GDS60P

NORME CAN/CSA Z240MH SERIE DE MAISONS MOBILES EQUIPEES AU GAZ,

 

 

 

 

 

EN VIGUEUR AU CANADA OU AUX ETATS-UNIS DE LA NORME DE SECURITE

CDVS600N

CDVS600N

 

 

CS600P

 

 

 

CDVS600P

 

 

 

 

 

ET DE CONSTRUCTION DE MAISONS MANUFACTUREES, TITRE 24 CFR,

TOP VENT

REAR VENT

 

 

 

REAR VENT

TOP VENT

SECTION 3280. DANS LE CAS OU CETTE NORME D’ETATS-UNIS NE PEUT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ETRE APPLIQUEE, SE REFERER A LA NORME RELATIVE AU CRITERE DE

0-4500

0-4500

0-4500

ALTITUDE (FT/PI) ELEVATION

0-4500

0-4500

 

0-4500

 

MESURES DE SECURITE CONTRE L’INCENDIE POUR LES INSTALLATIONS

 

 

DANS LES MAISONS MANUFACTURES, LES SITES ET LES COMMUNAUTES,

35,000

*21,000

35,000

INPUT (BTU/H) ALIMENTATION

31,500

*21,000

31,500

 

 

ANSI/NFPA 501A.

 

 

21,000

*12,000

21,000 REDUCED INPUT (BTU/H) ALIMENTATION REDUITE 22,000

*13,000

22,000

 

AFUE: 64%

 

 

24,500

*14,700

 

OUTPUT (BTU/H) RENDEMENT

 

*14,700

22,050

 

MINIMUM AND MAXIMUM HORIZONTAL VENT LENGTHS ARE 25 INCHES AND 20

 

 

 

FEET RESPECTIVELY FOR TOP VENTED UNITS AND 13 INCHES AND 20 FEET

#35

#45

#35

ORIFACE

 

#53

#55

 

#53

 

 

RESPECTIVELY FOR REAR VENTED UNITS. LES LONGUEURS HORIZONTALES

 

*WHEN VENTING OFF THE REAR OF THE UNIT AND TERMINATING HORIZONTALLY

 

 

 

 

 

 

 

 

MINIMALE ET MAXIMALE SONT 25 POUCES ET 20 PIEDS RESPECTIVEMENT

MANIFOLD PRESSURE: 3.5 INCHES W.C. (NG) / 10 INCHES W.C.

OPTIONALBLOWER KIT / ENSEMBLE DE

 

 

 

 

 

POUR UN EVACUATION VERTICALE ET 13 POUCES ET 20 PIEDS RESPECTIVE-

 

 

 

 

 

MENT POUR UN EVACUATION HORIZONTALE.

(LP)

 

 

 

VENTILATEUR FACULTATIF: GS64-KT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

THE APPLIANCE MUST BE VENTED USING THE APPROPRIATE NAPOLEON

PRESSION AU COLLECTEUR: 3.5” (GN) / 10” (PG) D’UNE COL-

AVERTISSEMENT: N’AJOUTEZ PAS A CET APPAREIL AUCUN

VENT KITS. SEE OWNERS INSTALLATION MANUAL FOR VENTING SPECIFICS.

ONNE DÉAU

 

 

 

MATERIAU DEVANT ENTRER EN CONTACT AVEC LES FLAMMES

 

 

 

PROPER REINSTALLATION AND RESEALING IS NECESSARY AFTER SERVICING

MIN SUPPLY PRESSURE: 4.5” W.C. (NG) / 11” (LP)

AUTRE QUE CELUI QUI EST FOURNI AVEC CET APPAREIL PAR

THE VENT-AIR INTAKE SYSTEM.

PRESSION D’ALIMENTATION MIN: 4.5” (GN) / 11” (PG) D’UNE

LE FABRICANT.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

L’APPAREIL DOIT EVACUER SES GAZ EN UTILISANT L’ENSEMBLE D’EVACUATION

COLONNE D’EAU

 

 

MINIMUM CLEARANCE TO COMBUSTIBLE MATERIAL / DEGAGE-

 

 

PROPRE A NAPOLEON. REFERER AU MANUEL D’INSTALLATION DE PROPRI-

MAX. SUPPLY PRESSURE: 7” W.C. (NG) / 13” W.C. (LP)

MENTS MINIMAUX DES MATERIAUX COMBUSTIBLES:

ETAIRE POUR L’EVACUATION PRECISE. IL EST IMPORTANT DE BIEN REIN-

PRESSION D’ALIMENTATION MAX: 7” (GN) / 13” (PG) D’UNE

A

6”

 

 

 

 

 

 

 

 

COLONNE D’EAU

 

 

B

6”

 

 

 

 

 

 

 

 

STALLER ET RESCELLER L’EVENT APRES AVOIR ASSURE LE MAINTIEN DU

 

 

 

 

 

 

 

 

 

 

SYSTEME DE PRISE D’AIR.

 

 

FOR USE WITH GLASS DOORS CERTIFIED WITH THIS UNIT ONLY.

C

2”

 

 

 

 

 

 

 

 

SERIAL NUMBER

 

 

UTILISER AVEC LES PORTES VITREES HOMOLOGUEES SEULE-

20” TO CEILING FROM STOVE TOP

 

 

 

 

 

 

 

 

GDS/CDVS60

 

MENT AVEC CETTE UNITE.

 

 

1” TO DIRECT VENT AND B-VENT / L’EVACUATION DIRECTE &

NO. DE SERIE

 

WARNING: DO NOT ADD ANY MATERIAL TO THE APPLIANCE,

L’EVACUATION B

 

 

 

 

 

 

 

 

 

 

WHICH WILL COME IN CONTACT WITH THE

 

6” TO C-VENT/ A L’EVACUATION C

 

 

 

 

 

 

 

 

WOLF STEEL LTD BARRIE, ON CANADA

FLAMES, OTHER THAN THAT SUPPLIED BY THE

20” ENTRE LE DESSUS DU FOYER ET LE PLAFOND

MANUFACTURER WITH THE APPLIANCE.

 

ELECTRICAL RATING/CLASS: 115V 1.5AMP 60HZ

MADE IN CANADA / FABRIQUE AU CANADA

MODEL CS600/GS60

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

APPROVED FOR BEDROOM, & BEDSITTING ROOM INSTALLATION. HOMOLOGUE POUR INSTALLATION DANS UNE CHAMBRE A

 

 

 

COUCHER, & UN STUDIO. THIS APPLIANCE MUST BE INSTALLED USING AN ADAPTER KIT GS-150KT. CET APPAREIL DOIT ETRE

 

 

 

INSTALLE EN UTILISANT UN ENSEMBLE ADAPTATEUR GS-150KT.

 

 

 

 

 

 

 

 

 

 

 

W385-0459

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

INSTALLER: It is your responsibility to check off the appropriate box on the rating plate according to the model, venting and gas type of the unit.

For rating plate location, see “INSTALLATION OVERVIEW” section.

W415-0788 / A / 09.22.09

Image 7
Contents GDS60N & GS60N Table of Contents Installation Installation OverviewIntroduction General Instructions DimensionsGeneral Information We suggest that our gasModel Natural GAS/GAZ Natural Rating PlateShippingbracket Latch Care of GlassShipping Bracket Glass Door RemovalVenting Model GDS60 Refer to the section applicable to your installationPart Supplier Website Venting Lengths and ComponentsMinimum Feet Maximum Typical Vent InstallationsTOP Vent Minimum Feet Maximum Rear Vent Rise PlusMinimum Plus Rise To Grade Minimum Special Vent Installations 3.3.1 Periscope TerminationCorner Termination GradeVent Terminal Clearances Installations CanadaRear Exit Venting Application Flow Chart TOP ExitElbow Vent Length Values DefinitionsFeet Inches HT VT TOP Exit Horizontal TerminationFormula 1 HT VT Formula 2 HT + VT 40 FT Horizontal Vent RUN Plus Offset in Feet HT Rear Exit Horizontal Termination10c 11a TOP or Rear Exit Vertical Termination11c Orifice Replacement Installation Preparation Model GDS60Rear Vent Termination Changing a TOP Vent to a Rear Vent Minimum Clearance to Combustibles InstallationMaintain These Minimum Clearances to Combustibles Wall and Ceiling Protection Horizontal InstallationHorizontal AIR Terminal Installation Model GDS60 Vertical InstallationInner Pipe Vertical AIR Terminal Installation Model GDS60High Temperature Sealant Inner Flex Pipe Roof SupportAppliance Vent Connection Model GDS60 Mobile Home Installation Model GDS60GAS Installation High Temperature SealantVent Specifics Model GS60 5.7.1 Chimney Installation Optional Wall Switch / ThermostatWire Size MAX. Length Combustion AIR Installing B VentMore MIN Flat Roof Wall Adding Vent SectionsCaulking Storm Collar Weather Sealant Flashing Installing Flashing and Storm CollarReturn Flange Glass Door Installation and RemovalFinishing Front Cast RemovalLOG Placement Glass / Door ReplacementLogo Placement Access Cover Plate Switch and Bracket InstallationSlot Removed Screws Optional Blower InstallationWiring Diagram Operating Instructions OperationModel GS60 only Venting Action Check Lighting Instructions Anti Condensation SwitchFlame Characteristics AdjustmentPilot Burner Adjustment Venturi AdjustmentMaintenance Common Components ReplacementsGS60 Components Roof Terminal Kits 49 50 Symptom Problem Trouble ShootingSymptom Problem Test Solution GS600 only HOTGDS600 only Glass Embers onlyConditions and Limitations WarrantyAppliance Service History Service History