DISCONNECTING THE EXTERNAL UNIT
Notice: the
The guarantee does not cover multiple installation.
Should it be necessary to disconnect, then go about it as follows:
•ask someone to help you operate the air conditioner via the remote control,
•put the desired temperature at 18 °C
•start the air conditioner, wait until you can also hear the compressor turning
•unscrew the caps from the valves and shut the upper valve (thin duct) with the socket wrench
•wait up to 1 minute: you will hear the sound of the compressor changing also shut the lowest valve (thick duct) with the socket wrench
•immediately switch the air conditioner off by taking the plug from the socket
•after both valves have been shut completely put the protective caps back on
•disconnect the same way as indicated for connecting; place the protective caps on the
Notice: if you are in any doubt or uncertainty leave this work to the installer.