TROUBLESHOOTING
Instructions relating to heating (*) are applicable only to “HEAT & COOL MODEL” (Reverse Cycle).
| Symptom | Items to check | See Page |
|
|
|
|
CHECK ONCE | Doesn’t operate at all: | ● Has the circuit breaker been turned off? |
|
MORE |
| ● Has there been a power failure? | — |
|
| ● Has a fuse blown out, or a circuit breaker been tripped? |
|
|
| ● Is the timer operating? | 6 to 8 |
| Poor Cooling (or *Heating) | ● Is the air filter dirty? |
|
| performance: | ● Are the air conditioner’s intake grille or outlet port blocked? |
|
|
| ● Did you adjust the room temperature settings (thermostat) correctly? |
|
|
| ● Is there a window or door open? | — |
|
| ● In the case of Cooling operation, is a window allowing bright sunlight | |
|
|
| |
|
| to enter? (Close the curtains.) |
|
|
| ● In the case of Cooling operation, are there heating apparatus and |
|
|
| computers inside the room, or are there too many people in the room? |
|
|
| ● Is the unit set for QUIET operation? | — |
If the problem persists after performing these checks, or if you notice burning smells, stop operation immediately, turn off electric breaker, and consult with authorized service personnel.
OPERATING TIPS
Instructions relating to heating (*) are applicable only to “HEAT & COOL MODEL” (Reverse Cycle).
*Heating Performance
●This air conditioner operates on the
●
*When Indoor and Outdoor Temperature are High
●When both indoor and outdoor temperatures are high during use of the heating mode, the outdoor unit’s fan may stop at times.
*Microcomputer-controlled Automatic Defrosting
●When using the Heating mode under conditions of low outdoor temperature and high humidity, frost may form on the outdoor unit, resulting in reduced operating performance.
In order to prevent this kind of reduced performance, this unit is equipped with a
ing function. During the defrost cycle, the indoor fan will shutdown and will be displayed on the remote controller. It will take anywhere from 4 to 15 minutes before the air conditioner starts up again.
●After heating operation stops, if frost forms on the outdoor unit, the unit will start Automatic Defrosting operation. At this time, the outdoor unit will automatically stop after operating for a few minutes.
Low Ambient Cooling
●When the outdoor temperature drops, the outdoor unit’s fans may switch to Low Speed, or 1 of the fans may stop intermittently.
Dual Remote Controllers (optional)
An additional remote controller can be added up to the maximum of 2 remote controllers. Either remote controller can control the air conditioner. However, the timer functions cannot be used at the secondary unit.
Group Control
1 remote controller can control up to 16 air conditioners.
All of the air conditioners will be operated with the same settings.
Group control cannot be used when using it by the multi type.