Bard FLF110D48F, FLR140D60F, FLR110D48F, FLR085D36F FLF/FLR 085, 110 and 140 Specification Sheet

Page 5

FLF/FLR 085, 110 AND 140 SPECIFICATION SHEET

 

TOP VIEW

J

RETURN

SUPPLY

 

DUCT

 

DUCT

D

FIGURE 1

FLF/R MODELS DIMENSIONS

TABLE 2

FLF/R MODELS DIMENSIONS (INCHES)

 

 

 

 

 

Plenum

 

 

 

 

 

 

 

 

 

Cabinet

 

Openings

Flue Conection

 

Air Filters

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Model

A

B

 

C

D x E

D x F

 

G

 

 

 

 

No.

Number

Width

Depth

 

Height

Supply

Return

Location

Dia.

H

J

Size

 

Used

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FLF085D36F

23

48.125

 

36.625

22x20

22x14

Front

6

31.625

5.125

16 x 20 x 1

 

1

FLR085D36F

23

48.125

 

36.625

22x20

22x14

Rear

6

31.625

5.125

16 x 20 x 1

 

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FLF110D48F

23

48.125

 

40.625

22x20

22x14

Front

6

35.625

5.125

20 x 20 x 1

 

1

FLF110D60F

23

48.125

 

40.625

22x20

22x14

Front

6

35.625

5.125

20 x 20 x 1

 

1

FLR110D48F

23

48.125

 

40.625

22x20

22x14

Rear

6

35.625

5.125

20 x 20 x 1

 

1

FLR110D60F

23

48.125

 

40.625

22x20

22x14

Rear

6

35.625

5.125

20 x 20 x 1

 

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FLR140D60F

26

50.250

 

47.625

25x20

25x16

Rear

6

42.125

- - -

20 x 25 x 1

 

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1Washable type filter 1” nom. thickness

 

G

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

F

 

 

 

 

 

E

 

 

 

 

 

 

 

 

 

 

 

 

 

"FLF" FLUE

 

REAR FLUE

KNOCKOUT

 

 

 

 

 

ON "FLR" MODELS

OPTIONAL

 

 

 

 

 

 

 

 

 

 

 

 

HIGH VOLTAGE

 

 

 

 

 

 

ENTRANCE

OPTIONAL

LOW VOLTAGE

"FLF" FLUE KNOCKOUT

A

B

"FLF" FLUE

KNOCKOUT

LOW VOLTAGE

ENTRANCE

H

ENTRANCE

OIL

C

HIGH VOLTAGE

 

ENTRANCE

Page

Manual

5 of 42

2100-422M

ENTRANCE

OPTIONAL

FILTEROIL

DOORENTRANCE

FRESH AIR

KNOCKOUT

LEFT SIDE VIEW

OPTIONAL

OIL ENTRANCE

FRONT VIEW

RIGHT SIDE VIEW

MIS-1815 A

Image 5
Contents OIL Furnace Installation Instructions Contents For More INFORMATION, Contact These Publishers Getting Other Information and PublicationsMinimum Clearances Equipment SelectionLocating the Furnace FLF/FLR 085, 110 and 140 Specification Sheet Supply Specification Sheet FC085 Model Dimensions Counterflow Specification SheetInstalling a Cooling Unit Installing the FurnaceInstruments Required for Proper Setup of the Furnace InstallationFactory Wiring WiringField Wiring Electrical DataTypical Unit Setup FLF Unit Shown Typical Unit Setup FLF Unit ShownI m n e y Beckett AFG or NX OIL Burner Typical Single Inside Tank InstallationOIL Line Piping Genisys 7505 Primary Control Beckett Cleancut OIL PumpBeckett Solid State Igniter Burner States Reset Button OperationBeckett Genisys Table B Status Lights Table a Reset Button OperationPriming the Pump CAD Cell Resistance IndicatorDisable Function Resetting from Restricted LockoutElectronic Blower Control Cleaner ConnectionFurnace Data Burner Setup and Adjustment ProceduresCombustion Diagnosis Combustion Adjustment StepsPreparation Steps Short Form Adjustment Procedure Typical Smoke CO2 Chart with Adjustment Range High Air Settings Low Bacharach Smoke NumberPressure Gauge Connection to Bleed Port Correlation of Percent of CO2, O2 and Reserve AIR No Fuel OIL Efficiency Chart NET Stack TEMP. Degrees FRecommended START-UP Settings Removing GUN Assembly GUN Assembly AdjustmentCombustion AIR Requirements Spacing of ElectrodesCombustion AIR Boot Assembly AFG Burner Combustion AIR Boot AssemblyALL AIR from Inside Building Appliances Located in Confined SpacesAppliances Located in Confined Spaces ALL AIR from Outdoors Minimum Ventilation OpeningsALL Ventilation AIR from Outdoors Manual 2100-422M Venting Options Louvers and GrillesThermostat Vertical VentingAFG AIR Filters Typical Installation of FR25 Filter KITLO-BOY Models Filter Locations Filter Installation LO-BOY ModelsLubrication Service HintsInspect AIR Filter Final Inspection and TestRemoval of Burner only Combination Combustion CHAMBER/BURNER Mounting SystemRemoval of Entire Combustion Chamber Mounting System To Remove Burner onlyTo Remove the Entire Combustion Chamber Mounting System Care of Finish Cleaning of the Heat ExchangerCommon Causes of Trouble Chart FH110D48F Data Chart FH085D36F DataChart FH110D60F Data Chart FLF/FLR085D36F DataChart FC085D36F Data Chart FLR140D60F DataExchanger FH Series Wiring Diagram4047-119 E 4047-120 D