Bard Beckett AFG Oil Burner Air Adjustment & Specifications for Furnaces

Page 6

Manual Page

FIGURE 2

FH MODELS DIMENSIONS

2100-422M 6 of 42

19 1/4"

TOP VIEW

19 7/8"

FLUE

KNOCKOUT

FLUE

KNOCKOUT

OPTIONAL

HIGH VOLTAGE

ENTRANCE

OPTIONAL

LOW VOLTAGE

ENTRANCE

OPTIONAL

OIL

ENTRANCE

OIL

ENTRANCE

21 7/8"

23"

FH085 AND FH110

SUPPLY SPECIFICATION SHEET

OPENING

30 1/2"

FLUE

KNOCKOUT

REAR CLEANOUT

DOOR

HIGH

VOLTAGE

ENTRANCE

53" (FH085) 59" (FH110)

LOW VOLTAGE

ENTRANCE

 

 

 

RETURN

 

 

 

OPENING

16"

(CUT OUT)

 

 

 

 

 

 

 

FRESH AIR

KNOCKOUT

VESTIBULE

DOOR

OPTIONAL

OIL

ENTRANCE

RETURN OPENING (CUT OUT)

LEFT SIDE VIEW

FRONT VIEW

RIGHT SIDE VIEW MIS-1814 A

Image 6
Contents OIL Furnace Installation Instructions Contents Getting Other Information and Publications For More INFORMATION, Contact These PublishersEquipment Selection Locating the FurnaceMinimum Clearances FLF/FLR 085, 110 and 140 Specification Sheet Supply Specification Sheet Counterflow Specification Sheet FC085 Model DimensionsInstruments Required for Proper Setup of the Furnace Installing the FurnaceInstalling a Cooling Unit InstallationField Wiring WiringFactory Wiring Electrical DataTypical Unit Setup FLF Unit Shown Typical Unit Setup FLF Unit ShownI m n e y Typical Single Inside Tank Installation OIL Line PipingBeckett AFG or NX OIL Burner Beckett Cleancut OIL Pump Beckett Solid State IgniterGenisys 7505 Primary Control Reset Button Operation Beckett GenisysBurner States Table a Reset Button Operation Table B Status LightsCAD Cell Resistance Indicator Priming the PumpResetting from Restricted Lockout Disable FunctionCleaner Connection Electronic Blower ControlBurner Setup and Adjustment Procedures Furnace DataCombustion Adjustment Steps Preparation StepsCombustion Diagnosis Short Form Adjustment Procedure High Air Settings Low Bacharach Smoke Number Typical Smoke CO2 Chart with Adjustment RangePressure Gauge Connection to Bleed Port No Fuel OIL Efficiency Chart NET Stack TEMP. Degrees F Recommended START-UP SettingsCorrelation of Percent of CO2, O2 and Reserve AIR Combustion AIR Requirements GUN Assembly AdjustmentRemoving GUN Assembly Spacing of ElectrodesAFG Burner Combustion AIR Boot Assembly Combustion AIR Boot AssemblyAppliances Located in Confined Spaces ALL AIR from Inside BuildingMinimum Ventilation Openings ALL Ventilation AIR from OutdoorsAppliances Located in Confined Spaces ALL AIR from Outdoors Manual 2100-422M Thermostat Louvers and GrillesVenting Options Vertical VentingAFG Typical Installation of FR25 Filter KIT AIR FiltersFilter Installation LO-BOY Models LO-BOY Models Filter LocationsInspect AIR Filter Service HintsLubrication Final Inspection and TestCombination Combustion CHAMBER/BURNER Mounting System Removal of Burner onlyTo Remove Burner only To Remove the Entire Combustion Chamber Mounting SystemRemoval of Entire Combustion Chamber Mounting System Cleaning of the Heat Exchanger Common Causes of TroubleCare of Finish Chart FH110D60F Data Chart FH085D36F DataChart FH110D48F Data Chart FLF/FLR085D36F DataChart FLR140D60F Data Chart FC085D36F DataFH Series Wiring Diagram Exchanger4047-119 E 4047-120 D