Bard FLR110D60F, FLR140D60F, FLR110D48F Counterflow Specification Sheet, FC085 Model Dimensions

Page 7

FIGURE 3

FC085 MODEL DIMENSIONS

22"

COUNTERFLOW 20"

SPECIFICATION

SHEET

RETURN

OPENING

30 5/8"

TOP VIEW

FLUE

KNOCKOUT

OPTIONAL

HIGH VOLTAGE

ENTRANCE

OPTIONAL

LOW VOLTAGE

ENTRANCE

OIL ENTRANCE

OPTIONAL OIL ENTRANCE

FRESH AIR

KNOCKOUT

LEFT SIDE VIEW

SUPPLY

OPENING

23"

FRONT VIEW

FLUE

KNOCKOUT

 

FLUE

 

KNOCKOUT

54 1/4"

REAR

 

CLEANOUT

 

DOOR

 

LOW VOLTAGE

 

ENTRANCE

 

HIGH VOLTAGE

 

ENTRANCE

 

OPTIONAL

 

OIL ENTRANCE

RIGHT SIDE VIEW

18 1/8"

BOTTOM VIEW

 

19 1/8"

MIS-1826 A

 

Manual

2100-422M

Page

7 of 42

Image 7
Contents OIL Furnace Installation Instructions Contents For More INFORMATION, Contact These Publishers Getting Other Information and PublicationsLocating the Furnace Equipment SelectionMinimum Clearances FLF/FLR 085, 110 and 140 Specification Sheet Supply Specification Sheet FC085 Model Dimensions Counterflow Specification SheetInstallation Installing the FurnaceInstalling a Cooling Unit Instruments Required for Proper Setup of the FurnaceElectrical Data WiringFactory Wiring Field WiringTypical Unit Setup FLF Unit Shown Typical Unit Setup FLF Unit ShownI m n e y OIL Line Piping Typical Single Inside Tank InstallationBeckett AFG or NX OIL Burner Beckett Solid State Igniter Beckett Cleancut OIL PumpGenisys 7505 Primary Control Beckett Genisys Reset Button OperationBurner States Table B Status Lights Table a Reset Button OperationPriming the Pump CAD Cell Resistance IndicatorDisable Function Resetting from Restricted LockoutElectronic Blower Control Cleaner ConnectionFurnace Data Burner Setup and Adjustment ProceduresPreparation Steps Combustion Adjustment StepsCombustion Diagnosis Short Form Adjustment Procedure Typical Smoke CO2 Chart with Adjustment Range High Air Settings Low Bacharach Smoke NumberPressure Gauge Connection to Bleed Port Recommended START-UP Settings No Fuel OIL Efficiency Chart NET Stack TEMP. Degrees FCorrelation of Percent of CO2, O2 and Reserve AIR Spacing of Electrodes GUN Assembly AdjustmentRemoving GUN Assembly Combustion AIR RequirementsCombustion AIR Boot Assembly AFG Burner Combustion AIR Boot AssemblyALL AIR from Inside Building Appliances Located in Confined SpacesALL Ventilation AIR from Outdoors Minimum Ventilation OpeningsAppliances Located in Confined Spaces ALL AIR from Outdoors Manual 2100-422M Vertical Venting Louvers and GrillesVenting Options ThermostatAFG AIR Filters Typical Installation of FR25 Filter KITLO-BOY Models Filter Locations Filter Installation LO-BOY ModelsFinal Inspection and Test Service HintsLubrication Inspect AIR FilterRemoval of Burner only Combination Combustion CHAMBER/BURNER Mounting SystemTo Remove the Entire Combustion Chamber Mounting System To Remove Burner onlyRemoval of Entire Combustion Chamber Mounting System Common Causes of Trouble Cleaning of the Heat ExchangerCare of Finish Chart FLF/FLR085D36F Data Chart FH085D36F DataChart FH110D48F Data Chart FH110D60F DataChart FC085D36F Data Chart FLR140D60F DataExchanger FH Series Wiring Diagram4047-119 E 4047-120 D