Table 3-2 Technical Specifications for Power Supply Module

Chapter 3 Summary of Power and Cooling System Features

Power Supply Module

Key Features

The power supply module has the following key features:

Automatic remote enable/disable signal: Ensures that the power supply remains off until fully seated and turns the power supply off during removal.

Operates as a single or redundant module.

Hot-swappable, accessible from the front of the chassis.

Current sharing when two power supplies reside in a chassis (the power supplies do not load share).

Four DC voltage outputs: +3.3V, +5V, +12V, and –12V.

AC input range of operation: 100 to 240 VAC.

IEC 320-C14 AC input receptacle.

Overvoltage protection: Power supply shuts down if the power output exceeds the nominal output by 120 percent.

Automatic thermal shutdown: If the ambient temperature is too high, the power supply shuts down automatically; when the ambient temperature returns to a safe operating range, the power supply restarts automatically.

Automatic redundancy when two power supplies are installed.

Technical Specifications

Table 3-2lists the technical specifications for the power supply module.

Table 3-2 Technical Specifications for Power Supply Module

Type

Description

 

 

Dimensions and weight

10 lb (4.5 kg)

 

 

Temperature

Operating: 23 to 113ºF (–5 to 45ºC)

 

 

 

Nonoperating: –40 to 185ºF (–40 to 85ºC)

 

 

Relative humidity

Operating: 10 to 90% (noncondensing)

 

 

 

Nonoperating: 10 to 95% (noncondensing)

 

 

Thermal shock

Operating: –5 to 45ºC, 0.5ºC/minute

 

 

 

Nonoperating: –40 to 85ºC, changeover time between 2 and 3 minutes

 

 

 

 

 

 

 