Chapter 2 Processor Cards Feature Summary
Analog Station Interface Cards
Table
| Type | Description | |||
|
|
| |||
| Optional Flash SIMM | ||||
| module | single | |||
| and |
|
|
|
|
|
|
| |||
| Optional cards | ASI81 and | |||
|
|
| |||
| Expansion slots | Two PVDM expansion slots, supporting | |||
|
| PVDMs | |||
|
|
|
| ||
| Cisco IOS requirement | • | ASI cards: 12.2(1) | ||
|
| • | MRP3 cards: 12.2(4)YH | ||
|
|
| |||
| Advanced data | IPSec 56, 3DES, Firewall | |||
| networking features |
|
|
|
|
|
|
| |||
| Codecs | G.711, G.723.1, G.726, and G.729a | |||
|
|
| |||
| Dimensions and weight | Height: 10.5 in. (26.67 cm) | |||
|
| Width: 1.6 in. (4.06 cm) | |||
|
| Depth: 8.25 in. (20.96 cm), with ejector handle | |||
|
| Depth: 7.0 in. (17.78 cm), without ejector handle | |||
|
| Weight (ASI81): 1.15 lb (0.52 kg), with no VICs, WICs, or VWICs | |||
|
| installed | |||
|
| Weight (ASI160): 1.36 lb (0.62 kg) | |||
|
|
| |||
| Power requirements | DC voltages: | |||
|
| 0.95A at +5V | |||
|
| 0.55A at +3.3V | |||
|
| 0.75A at +12V | |||
|
| Negligible current at | |||
|
|
| |||
| Power dissipation | 14W | |||
|
|
| |||
| Operating environment | Temperature range: 32 to 104ºF (0 to 40ºC) | |||
|
| Altitude: 10,000 ft (3000 m) | |||
|
| Relative humidity: 10 to 85% | |||
|
| Shock: 54 in./s (1.37 m/s) | |||
|
| Vibration: 0.35 Grms from 3 to 500 Hz | |||
|
|
| |||
| Nonoperating (storage) | Temperature shock: | |||
| environment | Temperature range: | |||
|
| Altitude: 15,000 ft (4570 m) | |||
|
| Relative humidity: 5 to 95% | |||
|
|
|
|
|
|
|
|
| Cisco ICS 7750 System Description |
|
|
|
|
|
| ||
|
|
|
| ||
|
|
|
|