Chapter 4 Summary of System Software Features
Cisco IOS
•Enables ICS System Manager to monitor the SPE and system alarm processor (SAP) cards and the chassis
•Determines the current status of the SPE on which it is running
The SAP card is responsible for reporting environmental and physical problems to the FMM. The FMM can detect the following faults:
•Ambient temperature and card temperature above threshold (40ºC)
•Fan failure
•Redundant power supply failure
•Power failure (if a UPS is available)
•Software module failure (such as ICS System Manager)
•Chassis card failure
When an error occurs, the FMM notifies the ICS System Manager.
ICS System Manager then reports problems on the logical layer in the form of SNMP traps.
FMM can attempt to correct a problem by
•Recovering from
•Sending syslog messages and updating the shared SPE memory
•Turning on or off the status LED on the SPE
In response to FMM notifications, System Manager can
•Turn on or off the status LED on any card
•Send an
Cisco IOS
Cisco IOS software is packaged in feature sets consisting of software images, which are specific to the platforms. Each feature set contains a specific set of Cisco IOS features. Table
Cisco ICS 7750 on MRP and ASI cards.
|
| Cisco ICS 7750 System Description |
|
|
|
|
| ||
|
|
|
| |
|
|
|