Chapter 3 Summary of Power and Cooling System Features
Cisco ICS 7750 Chassis, Backplane, and Fan Tray
•All cards are
•
•Fans are monitored and controlled through the SAP card.
•Grounding lug for grounding the chassis to the wall outlet, optionally including the uninterruptible power supply (UPS).
Technical Specifications
|
| Table | |||
Table | |||||
|
|
|
| ||
| Type |
| Description | ||
|
|
|
| ||
| Dimensions |
| Height: 15.75 in. (40.005 cm) | ||
|
|
| Width: 17.25 in. (43.815 cm) | ||
|
|
| Depth: 12.5 in. (31.75 cm) | ||
|
|
|
| ||
| Weight |
| 42 lb (18.9 kg) with 1 MRP, 1 SPE, 1 SSP, 1 SAP (4 cards total), and 1 power | ||
|
|
| supply installed | ||
|
|
|
| ||
| Power requirements |
| 100 to 240V | ||
|
|
| 47 to 63 Hz | ||
|
|
| 3A | ||
|
|
|
| ||
| Power dissipation |
| 275W maximum | ||
|
|
|
| ||
| UPS |
| Input voltage: 93 to 132 VAC | ||
|
|
| Frequency: 47 to 63 Hz | ||
|
|
| Output: 1050W/1400 VA | ||
|
|
| Run time: 8 minutes minimum | ||
|
|
| Optional external battery pack: approximately 30 minutes run time each | ||
|
|
|
| ||
| Acoustic noise |
| Operating: 48 dBA maximum | ||
|
|
|
| ||
| Temperature |
| Operating: 32 to 104ºF (0 to 40ºC) | ||
|
|
| Nonoperating: | ||
|
|
|
| ||
| Relative humidity |
| Operating: 10 to 85% | ||
|
|
| Nonoperating: 5 to 95% | ||
|
|
|
| ||
| Altitude |
| Operating: 10,000 ft (3000 m) | ||
|
|
| Nonoperating: 15,000 ft (4570 m) | ||
|
|
|
|
|
|
|
|