DS7400XiV4-EXP User Guide 6.0 Day to Day Operations

6.2.4Automatic Arming

EN 15

You can program each area to arm automatically once per day. You cannot program automatic arming from an RF (wireless) keypad. Programming automatic arming in Master Keypad mode affects all areas you have access to. If you program automatic arming in single area mode or from a single area keypad, it affects only the area you are working in.

Do this procedure at a text keypad because no visual clues are provided from an LED keypad.

Table 12: Automatic Arming

 

 

 

 

Setting the Automatic Arming Time

 

Notes

 

 

 

 

 

[Master PIN][#][0]

You can only set the Automatic Arming Time in Master Programming Mode.

[1]

To enter Automatic Arming Setup programming.

 

 

 

 

 

Enter the area number.

• If programming from a Master Keypad that is not in Single Partition Mode, you are

Press [#] to exit.

prompted to enter the area to program.

 

 

• You are allowed to program only the areas to which you are assigned.

 

• If programming from a standard keypad or from a Master Keypad in Single

 

Partition Mode, skip this step.

 

Enter a time for each day in

• Programming starts with Sunday. The keypad displays “Sunday –nn : nn”

24-hour clock format

• Enter the time in 24-hour clock format and press the [#] key. If you make a

 

mistake, press the [#] key twice to move back to your last entry.

 

• Time examples:

12 midnight = 2400#

12 noon = 1200#

 

 

12:01 am = 0001#

12:01 pm = 1201#

 

 

1:00 am = 0100#

1:00 pm = 1300#

 

 

Disabled = 0000#

 

 

 

 

 

6.2.5Delaying Automatic Arming

When automatic arming is set, a pre-arming period begins 15 minutes before the system arms automatically to inform occupants that the system is about to arm. The keypad sounders, and any outputs programmed to follow the keypad sounders, pulse five times every minute. During the last five minutes before arming, these sounders are on steady. Once per minute the keypad (text keypad only) displays “Arm in nn min./PIN OFF - extend.”

To delay automatic arming during the pre-arming period, use the appropriate command sequence from the table. To extend the automatic arming time at any time, use the delayed arming feature.

An RF3341 keypad gives no indication of the pre-arming period and cannot be used to delay automatic arming.

Table 13: Delaying Automatic Arming

 

 

 

 

Equipment

Command Sequence

What Happens

What To Do

 

 

 

 

Text Keypad LED

[PIN][Off]

The arming time is extended to 30 minutes from

Exit before the new

Keypad

 

the time you entered the command sequence.

automatic arming time.

 

 

A new pre-arming period begins 15 minutes

 

 

 

prior to the new automatic arming time.

 

RF3341,

 

Not applicable

 

RF3332/RF3322E,

 

 

 

RF3334/RF3334E

 

 

 

Note: The keypad volume setting also applies to the Auto Arm tone.

Bosch Security Systems 6/05 4998154961B

Image 15
Contents User Guide DS7400XiV4-EXPContents Typographical Conventions System OverviewConventions Used in This Guide Tips, Notes, Cautions, and WarningsUnderstanding Areas Partitions Your alarm system might be partitionedStatus LEDs Volume ControlUnderstanding the Text and LED Keypads Keypad LEDsUnderstanding RF Keypad and Keyfobs General InformationOption and Emergency Keys Day to Day Operations Standard OperationsNormal Arming Perimeter Instant Arming PIN Perimeter ArmingCustom Arming Maximum Security Arming Normal Disarming Optional Operations Quick ArmingForce Arming Zone Bypass Automatic Arming Delaying Automatic ArmingAutomatic Disarming Delayed ArmingChime Mode Access ControlThis feature can be used in armed or disarmed modes Changing the Date Setting the System ClockEmergency Procedures Create and Practice an Escape Plan Fire SafetyIf Installed in Family Residences No fire detection device or system is 100% foolproofInstallation Considerations Emergency Keypad Alarms/ Silencing AlarmsDisarming Your System under Duress Turning OFF Disarming Your System under DuressPersonal Identification Numbers PINs Removing a PINChanging a PIN PIN Authority Levels Changing the Expiration Date for Temporary PINsSystem Faults Error DisplaysSystem Faults System FaultsTesting Your System Zone TestTest the system weekly Zone Test Battery Tests Communicator TestCommunicator Test Fire Walk Test Fire Walk TestEvent History Readback Event History ReadbackScrolling through the History Events Text Keypad Only Master Keypad Text Keypad Only Master Keypad DisplaysMaster Keypad LEDs Arming from the Master Keypad Single Partition ModeExample of Accessing Single Partition Mode Arming from the Master KeypadDisarming from the Master Keypad Disarming from the Master KeypadGlossary Quick Reference Guide DS7400XiV4-EXP User Guide Quick Reference Guide System Features Reference Guide DS7400XiV4-EXP User Guide Notes DS7400XiV4-EXP User Guide Notes Bosch Security Systems 4998154961B