DS7400XiV4-EXP User Guide 8.0 Personal Identification Numbers (PINs)

EN 24

8.4PIN Authority Levels

0 = Master

Can enter all commands, add or change PINs in assigned areas, change the time and date, bypass, arm, disarm, perform system tests, system reset, and view history. User Number 001 must have the Master authority level. Any or all PINs can behave as a Master code. The Master code always has authority in all partitions.

1 = Unlimited

Can enter all commands, bypass, arm, disarm, system reset, and perform system tests. It cannot change PINs.

2 = General

Can bypass, arm, and disarm. It cannot change PINs, system reset, enter [#][7], or any of the [#][8] functions.

3 = Arm Only

Can arm the system with [PIN][ON] arming sequence only. Cannot perform other functions, including disarming.

4 = Temporary

Valid only for a specified time (the PIN expires on a pre-determined date). It can arm and disarm the system, but cannot perform any other functions. The code can be used from a Master keypad, but only in Single Partition Mode. If access is assigned to more than one area, you must enter a Temporary PIN expiration date for all assigned areas (refer to Section 8.5 Changing the Expiration Date for Temporary PINs).

5 = Duress

When the system is disarmed using the duress code, a silent report is sent to your monitoring service. The duress code is intended to be used when the user is forced to disarm the system. Refer to Section 7.10 Turning OFF (Disarming) Your System under Duress on page 22.

6 = Access Code

When a PIN with an access code is entered, any output programmed for access output (for example, door strikes) pulse on for 10 seconds (works when the system is armed or disarmed).

8.5Changing the Expiration Date for Temporary PINs

Since you can only change the expiration date for temporary PINs in Master Programming Mode, they are not programmable from an RF (wireless) keypad. Do this procedure at a text keypad because no visual clues are provided by an LED keypad.

Record your entries so they are available before you enter Master Programming Mode. Enter the parameters promptly. If a delay of 15 seconds or more occurs between entries, the 3-beep error tone sounds and the control panel exits from the programming mode.

Table 22: Changing the Expiration Date

 

 

 

 

Steps To Change the Expiration Date

Command Sequence

If Accepted, the Text Keypad Display Reads:

 

 

 

 

Enter Master Programming Mode.

[Master PIN][#][0]

“3 Change Date of Code Expiration” *

 

 

 

(display scrolls to this)

Enter 3 for Date of Code Expiration Setup

[3]

 

“Enter Month”

programming.

 

 

(01 ... 12)

Enter the Expiration Month.

[0][1] through [1][2]

“Enter Day”

 

January

December

(01 ... 31)

Enter the Expiration Day. The temporary PIN

[0][1] through [3][1]

“Enter Year”

expires at midnight on the day selected.

 

 

(XX) End with #

 

 

 

 

Enter the Year.

Last two digits of the year

“Month, Day, Year”

 

followed by [#]

A long beep signifies acceptance.

*Appears only when in Single Partition Mode. Note: Enter the command sequence [Master Code][#][3][#] to cause the text keypad to display the temporary code expiration date.

Bosch Security Systems 6/05 4998154961B

Image 24
Contents DS7400XiV4-EXP User GuideContents System Overview Conventions Used in This GuideTips, Notes, Cautions, and Warnings Typographical ConventionsYour alarm system might be partitioned Understanding Areas PartitionsVolume Control Understanding the Text and LED KeypadsKeypad LEDs Status LEDsUnderstanding RF Keypad and Keyfobs General InformationOption and Emergency Keys Day to Day Operations Standard OperationsNormal Arming Perimeter Instant Arming Perimeter Arming PINCustom Arming Maximum Security Arming Normal Disarming Optional Operations Quick ArmingForce Arming Zone Bypass Delaying Automatic Arming Automatic ArmingDelayed Arming Automatic DisarmingChime Mode Access ControlThis feature can be used in armed or disarmed modes Setting the System Clock Changing the DateEmergency Procedures Fire Safety If Installed in Family ResidencesNo fire detection device or system is 100% foolproof Create and Practice an Escape PlanEmergency Keypad Alarms/ Silencing Alarms Installation ConsiderationsTurning OFF Disarming Your System under Duress Disarming Your System under DuressPersonal Identification Numbers PINs Removing a PINChanging a PIN Changing the Expiration Date for Temporary PINs PIN Authority LevelsError Displays System FaultsSystem Faults System FaultsTesting Your System Zone TestTest the system weekly Zone Test Battery Tests Communicator TestCommunicator Test Fire Walk Test Fire Walk TestEvent History Readback Event History ReadbackScrolling through the History Events Text Keypad Only Master Keypad Text Keypad Only Master Keypad DisplaysMaster Keypad LEDs Single Partition Mode Example of Accessing Single Partition ModeArming from the Master Keypad Arming from the Master KeypadDisarming from the Master Keypad Disarming from the Master KeypadGlossary Quick Reference Guide DS7400XiV4-EXP User Guide Quick Reference Guide System Features Reference Guide DS7400XiV4-EXP User Guide Notes DS7400XiV4-EXP User Guide Notes Bosch Security Systems 4998154961B