Bosch Appliances DS7400XIV4-EXP manual Error Displays, System Faults

Page 25

DS7400XiV4-EXP User Guide 9.0 Error Displays

EN 25

9.0 Error Displays

You can read error displays only when the control panel is disarmed. Some control panel errors, such as battery trouble and any RF troubles, cause the keypad sounders to beep every 10 seconds.

You can silence the keypad sounders for 4 hours by entering [PIN][Off].

The sounders continue to sound until the problem is fixed.

Clear the error display as advised by your installing company, or if you are certain the problem is remedied.

Table 23: Error Displays

 

 

 

 

 

 

 

Error/Warning Messages

 

 

 

LED Keypad

 

Text Keypad

 

Meaning

 

 

 

 

 

 

 

 

 

 

Power Light

 

Control Trouble

 

There is an Error Message. To display the message, enter [PIN][#][8][7].

 

(green) flashing

 

Enter [#][8][7]

 

 

 

LED 1 on

 

AC Power Failure

 

There is a power failure and the control panel is operating on backup battery power.

 

 

 

 

 

 

 

LED 2 on

 

Battery Trouble *

 

If there was a power failure, wait at least two hours for the battery to recharge, then

 

 

 

 

 

enter [PIN][System Reset] to perform a battery test.

 

LED 3 on

 

Communicator Err **

 

The control panel failed to communicate with the central station.

 

 

 

 

 

 

 

LED 4 on

 

System Fault

 

Internal error in the control circuitry or optional circuitry. Refer to Section 9.1

 

 

 

 

 

System Faults.

 

LED 5 on

 

Keypad Fault

 

One of the keypads is not responding to the control panel.

 

 

 

 

 

 

 

LED 6 on

 

Keypad Tamper

 

One of the keypad housings was opened.

 

LED 7 on

 

Multiplex Bus

 

The multiplex bus is defective or is shorted.

 

 

 

 

 

 

 

LED 8 on

 

Aux. Power Fault

 

The auxiliary power is shorted.

 

 

 

Zone Trouble

 

One of the zones is not responding to the control panel. This might also be

 

 

 

 

 

displayed during power-up; if this occurs, ignore the message.

 

 

 

RF

 

Indicates a problem with an RF (wireless) zone.

 

 

 

Dirty Chamber

 

One of the multiplex smoke detectors failed the sensitivity test and might require

 

 

 

 

 

cleaning or replacement. Clear the keypad beep by entering [PIN][Off]

 

 

 

 

 

 

*The Battery Trouble message is cleared only by the [System Reset] command or another Automatic Battery Test, even after the problem is remedied.

**The Communicator Error message is cleared only by the [System Reset] command or the next successful Automatic System Off Normal report, even after the problem is remedied.

Bosch Security Systems 6/05 4998154961B

Image 25
Contents User Guide DS7400XiV4-EXPContents Conventions Used in This Guide System OverviewTips, Notes, Cautions, and Warnings Typographical ConventionsUnderstanding Areas Partitions Your alarm system might be partitionedUnderstanding the Text and LED Keypads Volume ControlKeypad LEDs Status LEDsGeneral Information Understanding RF Keypad and KeyfobsOption and Emergency Keys Standard Operations Day to Day OperationsNormal Arming Perimeter Instant Arming PIN Perimeter ArmingCustom Arming Maximum Security Arming Normal Disarming Quick Arming Optional OperationsForce Arming Zone Bypass Automatic Arming Delaying Automatic ArmingAutomatic Disarming Delayed ArmingAccess Control Chime ModeThis feature can be used in armed or disarmed modes Changing the Date Setting the System ClockEmergency Procedures If Installed in Family Residences Fire SafetyNo fire detection device or system is 100% foolproof Create and Practice an Escape PlanInstallation Considerations Emergency Keypad Alarms/ Silencing AlarmsDisarming Your System under Duress Turning OFF Disarming Your System under DuressRemoving a PIN Personal Identification Numbers PINsChanging a PIN PIN Authority Levels Changing the Expiration Date for Temporary PINsSystem Faults Error DisplaysSystem Faults System FaultsZone Test Testing Your SystemTest the system weekly Zone Test Communicator Test Battery TestsCommunicator Test Fire Walk Test Fire Walk TestEvent History Readback Event History ReadbackScrolling through the History Events Text Keypad Only Master Keypad Displays Master Keypad Text Keypad OnlyMaster Keypad LEDs Example of Accessing Single Partition Mode Single Partition ModeArming from the Master Keypad Arming from the Master KeypadDisarming from the Master Keypad Disarming from the Master KeypadGlossary Quick Reference Guide DS7400XiV4-EXP User Guide Quick Reference Guide System Features Reference Guide DS7400XiV4-EXP User Guide Notes DS7400XiV4-EXP User Guide Notes Bosch Security Systems 4998154961B