D9412GV3/D7412GV3 Operation and Installation Guide

9.0

Off-Board Points

 

 

 

Figure 21: Connecting D8128D OctoPOPITs to the D7412GV3

1 -

Zonex 1 address

2 -

Sensor loops

 

Refer to Address Switches in Section 9.4.4 Setting the OctoPOPIT Switches on page 44 for

 

information about making these switch settings. Refer to Table 15 on page 44 for information

 

about setting Switch 5.

 

 

For system supervision, do not use looped wire terminals. Break the wire run to provide supervision of the connections.

Bosch Security Systems, Inc. 10/10 F01U143070-03

47

Image 47
Contents D9412GV3/D7412GV3 Federal Communications Commission FCC Rules TrademarksCertifications and Approvals Listings and ApprovalsRinger Equivalence 0.0B Service Center in USAFCC Registration Number Contents Appendix B Point Address Charts Programmer and Accessory ConnectionsAppendix a System Wiring Diagrams, Issue a Tables Related Documentation IntroductionEffects Precautions during InstallationLightning Strikes GV3 Series Control Panel Differences Configuration and PartsFeatures D9412GV3 D7412GV3 OverviewParts Available by Separate Order Parts ListAssembly Literature PackModel Title Fire Intrusion AccessoriesCompatible Accessories1 Features in the D9412GV3 and D7412GV3 Keypads KeyswitchAccess Control Ground Fault DetectionMounting Enclosure InstallationInstallation Preparation Enclosure OptionsTerminal Installing the Control PanelConnecting Earth Ground Ground Fault Detect EnableLocking the Reset Pin Enabling Ground Fault DetectionGround Fault Specifications Ground Fault Impedance SpecificationsProgramming the Control Panel Completing the InstallationService Walk Test Procedure Installing the Point Chart LabelTesting the System Service Walk TestD9412GV3/D7412GV3 Operation and Installation Guide Text displays for 60 seconds Bosch Security Systems, Inc /10 F01U143070-03Test a device D7412GV3 Service Walk Test Flow Chart Secondary Power Terminals Power SupplyPrimary Power Terminals 1 Non-Power-Limited Wiring Battery Charging Circuit Replacing the Battery Charging and Battery LEDsD8132 Boost Battery Backup Adding a D8132 Investigate Low Battery reports immediately IfRecharge Cycle Battery Discharge and Recharge ScheduleCharging Status and Low Battery LEDs Discharge CycleCircuit Protection Power OutputsTotal Available Power Continuous Power Output Terminals 3, 8, 24,Voltage Output at Terminals 6, 7, Programmable Power Output Terminals 6, 7,Verification and Reset Relay A  NSC current = Alarm current Required Step AvailableLocation Telephone ConnectionsRegistration NotificationTelephone Line Monitor Phone LED RedOperation Monitor LED Green Dialing FormatDescription 11 D928 Dual Phone Line SwitcherPoint Sensor Loops On-Board PointsTerminals 11 to 22 Description Loop Voltage Range Point ParametersPoint Parameters Point Response Time 64 mm 1/4 Minimum distance Comm Point Zonex Bus D9412GV3 Terminals and D7412GV3 Off-Board Points5 D9412GV3/D7412GV3 Responses to Missing Point Conditions Off-Board Point ErrorsError Condition Result Additional Information D8125 and D9127 Popit ModulesConnecting the D8125 Popex to the D9412GV3 Control Panel Connecting the D8125 Popex to the D7412GV3 Control Panel Installing the D8125 Popex Module Program Record Sheet Wiring Data Expansion Loops to Popex ModulesPopit Sensor Loops Popit Module Point AssignmentsProgram Record Sheet Popit Labels D8128D OctoPOPIT ModuleD8128D OctoPOPIT Layout Requirements for Fire Initiation Applications D8128D OctoPOPIT Switch Settings for D9412GV3 and D7412GV3 Installation Setting the OctoPOPIT Switches Address SwitchesTerminal Strip Connections Wiring OctoPOPITsUsing the Terminal Strip Mounting OctoPOPITsConnecting D8128D OctoPOPITs to the D9412GV3 Connecting D8128D OctoPOPITs to the D7412GV3 Wiring Multiple D8128Ds Using Molex Connectors Using Molex ConnectorsOctoPOPIT Sensor Loops Testing Off-Board Points10.1 D8129 OctoRelay Off-Board RelaysRelay Outputs Configuring the D8129 OctoRelayD8129 OctoRelay Switch Settings Number of D8128Ds Used with D8129s Wiring Connections10.2 D811 Arm Status Relay Module D811 Module Wiring to the D9412GV3 D811 Module Wiring to the D7412GV3 Keypad Terminals 29 to Keypad Address SettingsArming Devices DescriptionKeypad Connections Wire Limits for Individual DevicesExtra Power for More Keypads D9412GV3 Keypad D7412GV3 Function Wire Terminal ColorOperation Maintained Contact Keyswitch11.3 D279A Independent Zone Control Silencing the Bell Momentary Contact12.3 D9131A Parallel Printer Interface Module InstallationSDI Devices SDI Addresses 88 12.4 D9210B Wiegand Control Interface ModuleSupervision Address SettingsNetwork Interface Modules Programmer Access Reports Programmer and Accessory ConnectionsProgrammer Connector Installer Keypad and Local Programmers ModeAccessory connector Programming connector Accessory Connector14.1 D9412GV3 Faceplate FaceplatesD7412GV3 Faceplate 14.2 D7412GV3 FaceplateD9412GV3 Control Panel Appendix a System Wiring Diagrams, Issue aD9412GV3 D9412GV3, SDI Devices System Wiring System Wiring D7412GV3 Control Panel D7412GV3, Power Supply Side System WiringD7412GV3 D7412GV3, SDI Devices System Wiring Zonex 1 Point Address Chart Appendix B Point Address ChartsZonex 2, Points 129 to 247 D9412GV3 Only Zonex 2 Point Address ChartPower Supply SpecificationsD9412GV3/D7412GV3 Operation and Installation Guide Notes Bosch Security Systems, Inc
Related manuals
Manual 154 pages 49.97 Kb