D9412GV3/D7412GV3 Operation and Installation Guide 11.0 Arming Devices

Figure 28: Power at Keypads

 

 

 

 

 

 

 

5

 

1

 

2

2

 

 

 

 

 

 

3

4

 

 

 

 

 

 

 

3

 

 

 

 

4

 

1 -

To control panel

4 -

Common

 

2 -

+12.0 VDC

5 - D8132 or external power supply

 

3 -

Data

 

 

 

11.3D279A Independent Zone Control

Any on-board or OctoPOPIT point can be programmed so that the D279A Independent Zone Control operates as independent point control (arming and disarming the point).

Refer to Point Assignments in the D9412GV3/D7412GV3 Program Entry Guide (P/N: F01U170807) for

programming information. Refer to the D279A Operation and Installation Instructions (P/N: 46458) for wiring and operation instructions.

11.4Keyswitch

11.4.1 Description

A maintained or momentary contact arming station (keyswitch) can be connected to master arm or disarm any of the areas in the system. The keyswitch is connected to an on-board or off-board point’s sensor loop. Relays can be programmed to activate arming status LEDs for keyswitch arming stations. Refer to Relays in the D9412GV3/D7412GV3 Program Entry Guide (P/N: F01U170807).

11.4.2 Programming

Refer to Point Assignments in the D9412GV3/D7412GV3 Program Entry Guide (P/N: F01U170807) for the correct programming for points used for keyswitches.

11.4.3 Installation

For maintained switches, connect the EOL resistor for the point at the keyswitch so that the switch opens the circuit when it operates. A short on the circuit produces an alarm if the area is armed and a trouble if it is disarmed. Refer to Figure 29 on page 58.

For momentary keyswitches, connect the EOL resistor at the keyswitch point so that when the keyswitch operates, it shorts the resistor. An open on the circuit causes an alarm if the area is armed and a trouble if it is disarmed. Refer to Figure 29 on page 58.

11.4.4Operation

Maintained Contact

If the point to which the keyswitch is connected is programmed for a maintained contact, an open on the arming circuit arms the area. All faulted points are force armed, regardless of the entry in the FA Bypass Max program item. Returning the circuit to normal disarms the area. Refer to Area Parameters and Point Assignments in the D9412GV3/D7412GV3 Program Entry Guide (P/N: F01U170807).

Bosch Security Systems, Inc. 10/10 F01U143070-03

57

Image 57
Contents D9412GV3/D7412GV3 Certifications and Approvals TrademarksListings and Approvals Federal Communications Commission FCC RulesService Center in USA FCC Registration NumberRinger Equivalence 0.0B Contents Programmer and Accessory Connections Appendix a System Wiring Diagrams, Issue aAppendix B Point Address Charts Tables Related Documentation IntroductionPrecautions during Installation Lightning StrikesEffects Features D9412GV3 D7412GV3 Configuration and PartsOverview GV3 Series Control Panel DifferencesAssembly Parts ListLiterature Pack Parts Available by Separate OrderAccessories Compatible Accessories1Model Title Fire Intrusion Features in the D9412GV3 and D7412GV3 Access Control KeyswitchGround Fault Detection KeypadsInstallation Preparation InstallationEnclosure Options Mounting EnclosureConnecting Earth Ground Installing the Control PanelGround Fault Detect Enable TerminalGround Fault Specifications Enabling Ground Fault DetectionGround Fault Impedance Specifications Locking the Reset PinProgramming the Control Panel Completing the InstallationTesting the System Installing the Point Chart LabelService Walk Test Service Walk Test ProcedureD9412GV3/D7412GV3 Operation and Installation Guide Bosch Security Systems, Inc /10 F01U143070-03 Test a deviceText displays for 60 seconds D7412GV3 Service Walk Test Flow Chart Power Supply Primary Power Terminals 1Secondary Power Terminals Non-Power-Limited Wiring D8132 Boost Battery Backup Adding a D8132 Replacing the Battery Charging and Battery LEDsInvestigate Low Battery reports immediately If Battery Charging CircuitCharging Status and Low Battery LEDs Battery Discharge and Recharge ScheduleDischarge Cycle Recharge CycleTotal Available Power Power OutputsContinuous Power Output Terminals 3, 8, 24, Circuit ProtectionVerification and Reset Relay Programmable Power Output Terminals 6, 7,A  NSC current = Alarm current Required Step Available Voltage Output at Terminals 6, 7,Registration Telephone ConnectionsNotification LocationOperation Monitor LED Green Phone LED RedDialing Format Telephone Line MonitorDescription 11 D928 Dual Phone Line SwitcherOn-Board Points Terminals 11 to 22 DescriptionPoint Sensor Loops Point Parameters Point ParametersLoop Voltage Range Point Response Time 64 mm 1/4 Minimum distance Comm Point Zonex Bus D9412GV3 Terminals and D7412GV3 Off-Board PointsError Condition Result Additional Information Off-Board Point ErrorsD8125 and D9127 Popit Modules 5 D9412GV3/D7412GV3 Responses to Missing Point ConditionsConnecting the D8125 Popex to the D9412GV3 Control Panel Connecting the D8125 Popex to the D7412GV3 Control Panel Installing the D8125 Popex Module Popit Sensor Loops Wiring Data Expansion Loops to Popex ModulesPopit Module Point Assignments Program Record SheetProgram Record Sheet Popit Labels D8128D OctoPOPIT ModuleD8128D OctoPOPIT Layout Requirements for Fire Initiation ApplicationsSetting the OctoPOPIT Switches InstallationAddress Switches D8128D OctoPOPIT Switch Settings for D9412GV3 and D7412GV3Using the Terminal Strip Wiring OctoPOPITsMounting OctoPOPITs Terminal Strip ConnectionsConnecting D8128D OctoPOPITs to the D9412GV3 Connecting D8128D OctoPOPITs to the D7412GV3 Wiring Multiple D8128Ds Using Molex Connectors Using Molex ConnectorsOctoPOPIT Sensor Loops Testing Off-Board Points10.1 D8129 OctoRelay Off-Board RelaysConfiguring the D8129 OctoRelay D8129 OctoRelay Switch SettingsRelay Outputs Wiring Connections 10.2 D811 Arm Status Relay ModuleNumber of D8128Ds Used with D8129s D811 Module Wiring to the D9412GV3 D811 Module Wiring to the D7412GV3 Arming Devices Keypad Address SettingsDescription Keypad Terminals 29 toExtra Power for More Keypads Wire Limits for Individual DevicesD9412GV3 Keypad D7412GV3 Function Wire Terminal Color Keypad ConnectionsKeyswitch 11.3 D279A Independent Zone ControlOperation Maintained Contact Silencing the Bell Momentary ContactInstallation SDI Devices12.3 D9131A Parallel Printer Interface Module SDI Addresses 88 12.4 D9210B Wiegand Control Interface ModuleAddress Settings Network Interface ModulesSupervision Programmer Connector Programmer and Accessory ConnectionsInstaller Keypad and Local Programmers Mode Programmer Access ReportsAccessory connector Programming connector Accessory Connector14.1 D9412GV3 Faceplate FaceplatesD7412GV3 Faceplate 14.2 D7412GV3 FaceplateD9412GV3 Control Panel Appendix a System Wiring Diagrams, Issue aD9412GV3 D9412GV3, SDI Devices System Wiring System Wiring D7412GV3 Control Panel D7412GV3, Power Supply Side System WiringD7412GV3 D7412GV3, SDI Devices System Wiring Zonex 1 Point Address Chart Appendix B Point Address ChartsZonex 2, Points 129 to 247 D9412GV3 Only Zonex 2 Point Address ChartPower Supply SpecificationsD9412GV3/D7412GV3 Operation and Installation Guide Notes Bosch Security Systems, Inc
Related manuals
Manual 154 pages 49.97 Kb

D9412GV3, D7412GV3 specifications

The Bosch Appliances D9412GV3 is a perfect blend of functionality and innovation, designed to meet the needs of modern households. This dishwasher is part of Bosch's reputation for creating high-quality, energy-efficient home appliances. With a sleek design and advanced technology, the D9412GV3 stands out in the crowded market of dishwashers.

One of the main features of the D9412GV3 is its remarkable efficiency. With an Energy Star rating, this model is designed to minimize water and energy consumption while still delivering exceptional cleaning performance. The EcoSense technology optimizes water usage, ensuring every wash cycle is both effective and economical, making it a responsible choice for energy-conscious consumers.

The dishwasher offers a spacious interior, capable of accommodating large loads. Its flexible rack system includes adjustable tines and folding platforms, making it easy to fit various dish sizes, from pots and pans to delicate glassware. Additionally, the third rack feature provides extra space for utensils and smaller items, enhancing its capacity and versatility.

In terms of cleaning power, the D9412GV3 is equipped with the PrecisionWash system. This cutting-edge technology features intelligent sensors that continuously scan and check the load, adjusting the wash cycle as needed for optimal results. Coupled with the 40 dBA noise level, it ensures that the dishwasher operates quietly in the background, so you can enjoy your home without disruptive sounds.

Another standout characteristic is the PureDry technology, an integrated drying system that uses a condensation process to gently dry dishes without the need for extra heat. This not only protects sensitive items but also saves energy, further enhancing the appliance's eco-friendly nature.

Ease of use is a priority for Bosch, as seen in the D9412GV3's user-friendly controls. The intuitive interface allows for selecting various wash cycles and options, including Heavy, Auto, and Quick options, catering to different cleaning needs. Additionally, the Time Delay feature provides the flexibility to set the dishwasher to run at a later time, great for aligning with your schedule.

In summary, the Bosch D9412GV3 combines innovative technologies with a user-centered design to deliver a top-tier dishwasher experience. Its energy-efficient operation, spacious interior, and advanced cleaning features make it an excellent choice for any kitchen, ensuring spotless dishes with minimal effort. With Bosch's commitment to quality, the D9412GV3 stands as a reliable and stylish addition to any modern home.