Bosch Appliances D7412GV3 manual D9412GV3, SDI Devices System Wiring System Wiring

Page 68

D9412GV3/D7412GV3 Operation and Installation Guide Appendix A: System Wiring Diagrams, Issue A

Figure 37: D9412GV3, SDI Devices System Wiring System Wiring

1 - Up to 16 supervised D1255 (all versions), D1255RB, D1256, D1256RB Keypads, or D1257RB or D1257 Fire Annunciators, or up to 8 supervised D1260 Keypads (all versions)

2 - Up to 8 D9210B Access Control Interface Modules

3 - Up to 3 supervised 9131A Parallel Printer Interface Modules, or other SDI devices

4 - Power limited, supervised

5 - Power limited

6 - DX4020 Network Interface Module or other SDI device

7 - D8125 POPEX No.1

8 - D8125 POPEX No. 2

9- Up to 119 D9127U/T POPITs

10 - Zonex 1: 15 D8128Ds maximum*

11 - Zonex 2: 15 D8128Ds maximum*

12 - Zonex 1: Up to 8 D8129s maximum*

13 - Zonex 2: Up to 8 D8129s maximum*

*The number of D8129 OctoRelays that can be connected to each zonex terminal on the control panel is limited by the number of D8128D OctoPOPITs connected to the same terminal. Refer to the D8128D Installation Guide (P/N: F01U070537) or the D8129 Operation and Installation Guide (P/N: F01U036302) for specific information.

All external connections except Terminal 5 (battery position) are power limited.

Fire and Intrusion devices must be on separate circuits. Refer to ICP-SDI-9114 Installation Instructions (P/N: F01U030068).

Bosch Security Systems, Inc. 10/10 F01U143070-03

68

Image 68
Contents D9412GV3/D7412GV3 Trademarks Certifications and ApprovalsListings and Approvals Federal Communications Commission FCC RulesRinger Equivalence 0.0B Service Center in USAFCC Registration Number Contents Appendix B Point Address Charts Programmer and Accessory ConnectionsAppendix a System Wiring Diagrams, Issue a Tables Introduction Related DocumentationEffects Precautions during InstallationLightning Strikes Configuration and Parts Features D9412GV3 D7412GV3Overview GV3 Series Control Panel DifferencesParts List AssemblyLiterature Pack Parts Available by Separate OrderModel Title Fire Intrusion AccessoriesCompatible Accessories1 Features in the D9412GV3 and D7412GV3 Keyswitch Access ControlGround Fault Detection KeypadsInstallation Installation PreparationEnclosure Options Mounting EnclosureInstalling the Control Panel Connecting Earth GroundGround Fault Detect Enable TerminalEnabling Ground Fault Detection Ground Fault SpecificationsGround Fault Impedance Specifications Locking the Reset PinCompleting the Installation Programming the Control PanelInstalling the Point Chart Label Testing the SystemService Walk Test Service Walk Test ProcedureD9412GV3/D7412GV3 Operation and Installation Guide Text displays for 60 seconds Bosch Security Systems, Inc /10 F01U143070-03Test a device D7412GV3 Service Walk Test Flow Chart Secondary Power Terminals Power SupplyPrimary Power Terminals 1 Non-Power-Limited Wiring Replacing the Battery Charging and Battery LEDs D8132 Boost Battery Backup Adding a D8132Investigate Low Battery reports immediately If Battery Charging CircuitBattery Discharge and Recharge Schedule Charging Status and Low Battery LEDsDischarge Cycle Recharge CyclePower Outputs Total Available PowerContinuous Power Output Terminals 3, 8, 24, Circuit ProtectionProgrammable Power Output Terminals 6, 7, Verification and Reset RelayA  NSC current = Alarm current Required Step Available Voltage Output at Terminals 6, 7,Telephone Connections RegistrationNotification LocationPhone LED Red Operation Monitor LED GreenDialing Format Telephone Line Monitor11 D928 Dual Phone Line Switcher DescriptionPoint Sensor Loops On-Board PointsTerminals 11 to 22 Description Loop Voltage Range Point ParametersPoint Parameters Point Response Time 64 mm 1/4 Minimum distance Comm Off-Board Points Point Zonex Bus D9412GV3 Terminals and D7412GV3Off-Board Point Errors Error Condition Result Additional InformationD8125 and D9127 Popit Modules 5 D9412GV3/D7412GV3 Responses to Missing Point ConditionsConnecting the D8125 Popex to the D9412GV3 Control Panel Connecting the D8125 Popex to the D7412GV3 Control Panel Installing the D8125 Popex Module Wiring Data Expansion Loops to Popex Modules Popit Sensor LoopsPopit Module Point Assignments Program Record SheetD8128D OctoPOPIT Module Program Record Sheet Popit LabelsRequirements for Fire Initiation Applications D8128D OctoPOPIT LayoutInstallation Setting the OctoPOPIT SwitchesAddress Switches D8128D OctoPOPIT Switch Settings for D9412GV3 and D7412GV3Wiring OctoPOPITs Using the Terminal StripMounting OctoPOPITs Terminal Strip ConnectionsConnecting D8128D OctoPOPITs to the D9412GV3 Connecting D8128D OctoPOPITs to the D7412GV3 Using Molex Connectors Wiring Multiple D8128Ds Using Molex ConnectorsTesting Off-Board Points OctoPOPIT Sensor LoopsOff-Board Relays 10.1 D8129 OctoRelayRelay Outputs Configuring the D8129 OctoRelayD8129 OctoRelay Switch Settings Number of D8128Ds Used with D8129s Wiring Connections10.2 D811 Arm Status Relay Module D811 Module Wiring to the D9412GV3 D811 Module Wiring to the D7412GV3 Keypad Address Settings Arming DevicesDescription Keypad Terminals 29 toWire Limits for Individual Devices Extra Power for More KeypadsD9412GV3 Keypad D7412GV3 Function Wire Terminal Color Keypad ConnectionsOperation Maintained Contact Keyswitch11.3 D279A Independent Zone Control Momentary Contact Silencing the Bell12.3 D9131A Parallel Printer Interface Module InstallationSDI Devices 12.4 D9210B Wiegand Control Interface Module SDI Addresses 88Supervision Address SettingsNetwork Interface Modules Programmer and Accessory Connections Programmer ConnectorInstaller Keypad and Local Programmers Mode Programmer Access ReportsAccessory Connector Accessory connector Programming connectorFaceplates 14.1 D9412GV3 Faceplate14.2 D7412GV3 Faceplate D7412GV3 FaceplateAppendix a System Wiring Diagrams, Issue a D9412GV3 Control PanelD9412GV3 D9412GV3, SDI Devices System Wiring System Wiring D7412GV3, Power Supply Side System Wiring D7412GV3 Control PanelD7412GV3 D7412GV3, SDI Devices System Wiring Appendix B Point Address Charts Zonex 1 Point Address ChartZonex 2 Point Address Chart Zonex 2, Points 129 to 247 D9412GV3 OnlySpecifications Power SupplyD9412GV3/D7412GV3 Operation and Installation Guide Notes Bosch Security Systems, Inc
Related manuals
Manual 154 pages 49.97 Kb

D9412GV3, D7412GV3 specifications

The Bosch Appliances D9412GV3 is a perfect blend of functionality and innovation, designed to meet the needs of modern households. This dishwasher is part of Bosch's reputation for creating high-quality, energy-efficient home appliances. With a sleek design and advanced technology, the D9412GV3 stands out in the crowded market of dishwashers.

One of the main features of the D9412GV3 is its remarkable efficiency. With an Energy Star rating, this model is designed to minimize water and energy consumption while still delivering exceptional cleaning performance. The EcoSense technology optimizes water usage, ensuring every wash cycle is both effective and economical, making it a responsible choice for energy-conscious consumers.

The dishwasher offers a spacious interior, capable of accommodating large loads. Its flexible rack system includes adjustable tines and folding platforms, making it easy to fit various dish sizes, from pots and pans to delicate glassware. Additionally, the third rack feature provides extra space for utensils and smaller items, enhancing its capacity and versatility.

In terms of cleaning power, the D9412GV3 is equipped with the PrecisionWash system. This cutting-edge technology features intelligent sensors that continuously scan and check the load, adjusting the wash cycle as needed for optimal results. Coupled with the 40 dBA noise level, it ensures that the dishwasher operates quietly in the background, so you can enjoy your home without disruptive sounds.

Another standout characteristic is the PureDry technology, an integrated drying system that uses a condensation process to gently dry dishes without the need for extra heat. This not only protects sensitive items but also saves energy, further enhancing the appliance's eco-friendly nature.

Ease of use is a priority for Bosch, as seen in the D9412GV3's user-friendly controls. The intuitive interface allows for selecting various wash cycles and options, including Heavy, Auto, and Quick options, catering to different cleaning needs. Additionally, the Time Delay feature provides the flexibility to set the dishwasher to run at a later time, great for aligning with your schedule.

In summary, the Bosch D9412GV3 combines innovative technologies with a user-centered design to deliver a top-tier dishwasher experience. Its energy-efficient operation, spacious interior, and advanced cleaning features make it an excellent choice for any kitchen, ensuring spotless dishes with minimal effort. With Bosch's commitment to quality, the D9412GV3 stands as a reliable and stylish addition to any modern home.