Bosch Appliances D7412GV3, D9412GV3 manual Compatible Accessories1, Model Title Fire Intrusion

Page 11

D9412GV3/D7412GV3 Operation and Installation Guide

3.0

Overview

 

 

 

3.2Accessories

Refer to the Bosch Security Systems, Inc. product catalog for additional information.

Table 3: Compatible Accessories1

 

 

 

 

 

 

 

 

 

 

 

Model

Title

UL 864

Fire

Intrusion

 

D122/D122L

Dual Battery Harness

X

X

X

 

D125B

Powered Loop Interface Module

X

X

X

 

D127

Reversing Relay

X

X

X

 

D129

Dual Class A Initiation Circuit Module

X

X

X

 

D130

Relay Module

X

X

X

 

D185

Reverse Polarity Module

 

 

X

X

 

D192G

Bell Circuit Supervision Module

X

X

X

 

D279A

Independent Zone Control (On-Board and OctoPOPIT Points)

 

 

 

 

X

 

D720R

LED Keypad (red)

 

 

X

X

 

D720W

LED Keypad (white)

 

 

X

X

 

D928

Dual Phone Line Switcher

X

X

X

 

D1255RB

Fire Keypad

X

X

X

 

D1256RB

Fire Keypad

X

X

X

 

D1257RB

Fire Alarm Annunciator

X

X

X

 

D1218

12 V, 17.2 Ah Rechargeable Battery

X

X

X

 

D1255/D1255B

Keypads (General Purpose)

 

 

X

X

 

D1255R

Text Keypad (red)

 

 

X

X

 

D1255W

Text Keypad (white)

 

 

X

X

 

D1256

Fire Keypad

 

 

X

 

 

 

D1257

Fire Alarm Annunciator

 

 

X

 

 

 

D1260/D1260B2

Keypads

 

 

X

X

 

D1640

16.5 VAC 40 VA Transformer

X

X

X

 

D8004

Transformer Enclosure

X

X

X

 

D8125

POPEX Module

X

X

X

 

D8125MUX

Multiplex Bus Interface

X

X

X

 

ISW-D8125CW-V2

Commercial Wireless Interface Module

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D8128D

OctoPOPIT Module

X

X

X

 

D8129

OctoRelay Module

X

X

X

 

D8130

Release Module

X

X

X

 

D8132

Battery Charger Module

 

 

X

X

 

D9127U/T

POPIT Module

X

X

X

 

D9131A

Parallel Printer Interface Module

 

 

X

X

 

D9210B

Access Control Interface Module

X

X

X

 

DX4020

Network Interface Module

X

X

X

 

ITS-DX4020-G

GPRS/GSM Communicator

X

X

X

 

ICP-SDI-9114

SDI Splitter

X

X

X

 

ZX776Z

PIR Motion Sensor [15 m (50 ft)] with POPIT

 

 

 

 

X

 

ZX794Z

PIR Motion Sensor [24 m (80 ft)] with POPIT

 

 

 

 

X

 

ZX865

 

PIR/Microwave Motion Sensor [+1.7C (+35F)] with POPIT

 

 

 

 

X

 

 

ZX938Z

PIR Motion Sensor [18 m (60 ft)] with POPIT

 

 

 

 

X

 

ZX970

 

PIR/Microwave Motion Sensor [+1.7C (+35F)] with POPIT

 

 

 

 

 

 

1Where the fire alarm transmitter is sharing on-premise communications equipment, the shared equipment must be UL Listed (ITE or fire protective signaling).

2Version 1.04 or above

Bosch Security Systems, Inc. 10/10 F01U143070-03

11

Image 11
Contents D9412GV3/D7412GV3 Federal Communications Commission FCC Rules TrademarksCertifications and Approvals Listings and ApprovalsRinger Equivalence 0.0B Service Center in USAFCC Registration Number Contents Appendix B Point Address Charts Programmer and Accessory ConnectionsAppendix a System Wiring Diagrams, Issue a Tables Related Documentation Introduction Effects Precautions during Installation Lightning Strikes GV3 Series Control Panel Differences Configuration and PartsFeatures D9412GV3 D7412GV3 OverviewParts Available by Separate Order Parts ListAssembly Literature PackModel Title Fire Intrusion AccessoriesCompatible Accessories1 Features in the D9412GV3 and D7412GV3 Keypads KeyswitchAccess Control Ground Fault DetectionMounting Enclosure InstallationInstallation Preparation Enclosure OptionsTerminal Installing the Control PanelConnecting Earth Ground Ground Fault Detect EnableLocking the Reset Pin Enabling Ground Fault DetectionGround Fault Specifications Ground Fault Impedance SpecificationsProgramming the Control Panel Completing the InstallationService Walk Test Procedure Installing the Point Chart LabelTesting the System Service Walk TestD9412GV3/D7412GV3 Operation and Installation Guide Text displays for 60 seconds Bosch Security Systems, Inc /10 F01U143070-03Test a device D7412GV3 Service Walk Test Flow Chart Secondary Power Terminals Power SupplyPrimary Power Terminals 1 Non-Power-Limited Wiring Battery Charging Circuit Replacing the Battery Charging and Battery LEDsD8132 Boost Battery Backup Adding a D8132 Investigate Low Battery reports immediately IfRecharge Cycle Battery Discharge and Recharge ScheduleCharging Status and Low Battery LEDs Discharge CycleCircuit Protection Power OutputsTotal Available Power Continuous Power Output Terminals 3, 8, 24,Voltage Output at Terminals 6, 7, Programmable Power Output Terminals 6, 7,Verification and Reset Relay A  NSC current = Alarm current Required Step AvailableLocation Telephone ConnectionsRegistration NotificationTelephone Line Monitor Phone LED RedOperation Monitor LED Green Dialing FormatDescription 11 D928 Dual Phone Line SwitcherPoint Sensor Loops On-Board PointsTerminals 11 to 22 Description Loop Voltage Range Point ParametersPoint Parameters Point Response Time 64 mm 1/4 Minimum distance Comm Point Zonex Bus D9412GV3 Terminals and D7412GV3 Off-Board Points5 D9412GV3/D7412GV3 Responses to Missing Point Conditions Off-Board Point ErrorsError Condition Result Additional Information D8125 and D9127 Popit ModulesConnecting the D8125 Popex to the D9412GV3 Control Panel Connecting the D8125 Popex to the D7412GV3 Control Panel Installing the D8125 Popex Module Program Record Sheet Wiring Data Expansion Loops to Popex ModulesPopit Sensor Loops Popit Module Point AssignmentsProgram Record Sheet Popit Labels D8128D OctoPOPIT ModuleD8128D OctoPOPIT Layout Requirements for Fire Initiation ApplicationsD8128D OctoPOPIT Switch Settings for D9412GV3 and D7412GV3 InstallationSetting the OctoPOPIT Switches Address SwitchesTerminal Strip Connections Wiring OctoPOPITsUsing the Terminal Strip Mounting OctoPOPITsConnecting D8128D OctoPOPITs to the D9412GV3 Connecting D8128D OctoPOPITs to the D7412GV3 Wiring Multiple D8128Ds Using Molex Connectors Using Molex ConnectorsOctoPOPIT Sensor Loops Testing Off-Board Points10.1 D8129 OctoRelay Off-Board RelaysRelay Outputs Configuring the D8129 OctoRelayD8129 OctoRelay Switch Settings Number of D8128Ds Used with D8129s Wiring Connections10.2 D811 Arm Status Relay Module D811 Module Wiring to the D9412GV3 D811 Module Wiring to the D7412GV3 Keypad Terminals 29 to Keypad Address SettingsArming Devices DescriptionKeypad Connections Wire Limits for Individual DevicesExtra Power for More Keypads D9412GV3 Keypad D7412GV3 Function Wire Terminal ColorOperation Maintained Contact Keyswitch11.3 D279A Independent Zone Control Silencing the Bell Momentary Contact12.3 D9131A Parallel Printer Interface Module InstallationSDI Devices SDI Addresses 88 12.4 D9210B Wiegand Control Interface ModuleSupervision Address SettingsNetwork Interface Modules Programmer Access Reports Programmer and Accessory ConnectionsProgrammer Connector Installer Keypad and Local Programmers ModeAccessory connector Programming connector Accessory Connector14.1 D9412GV3 Faceplate FaceplatesD7412GV3 Faceplate 14.2 D7412GV3 FaceplateD9412GV3 Control Panel Appendix a System Wiring Diagrams, Issue aD9412GV3 D9412GV3, SDI Devices System Wiring System Wiring D7412GV3 Control Panel D7412GV3, Power Supply Side System WiringD7412GV3 D7412GV3, SDI Devices System Wiring Zonex 1 Point Address Chart Appendix B Point Address ChartsZonex 2, Points 129 to 247 D9412GV3 Only Zonex 2 Point Address ChartPower Supply SpecificationsD9412GV3/D7412GV3 Operation and Installation Guide Notes Bosch Security Systems, Inc