14.0Faceplates

14.1D9412GV3 Faceplate

Figure 33: D9412GV3 Faceplate

1 - Charging status LED (yellow)

2 - Low battery LED (red)

3 - Color-coded battery leads

4 - Ground fault detect enable

5- Phone LED (red)

6 - Tip

7 - Telephone cord connector

8 - Ring

9 - S3, Point 8 EOL selection

10 - Operation monitor LED (green)

11 - Accessory connector

12 - Programming connector

Do not use with firmware version 8.11 or later 13 - Reset pin

14 - SDI quick connector

Bosch Security Systems, Inc. 10/10 F01U143070-03

64

Image 64
Contents D9412GV3/D7412GV3 Trademarks Certifications and ApprovalsListings and Approvals Federal Communications Commission FCC RulesFCC Registration Number Service Center in USARinger Equivalence 0.0B Contents Appendix a System Wiring Diagrams, Issue a Programmer and Accessory ConnectionsAppendix B Point Address Charts Tables Introduction Related DocumentationLightning Strikes Precautions during InstallationEffects Configuration and Parts Features D9412GV3 D7412GV3Overview GV3 Series Control Panel DifferencesParts List AssemblyLiterature Pack Parts Available by Separate OrderCompatible Accessories1 AccessoriesModel Title Fire Intrusion Features in the D9412GV3 and D7412GV3 Keyswitch Access ControlGround Fault Detection KeypadsInstallation Installation PreparationEnclosure Options Mounting EnclosureInstalling the Control Panel Connecting Earth GroundGround Fault Detect Enable TerminalEnabling Ground Fault Detection Ground Fault SpecificationsGround Fault Impedance Specifications Locking the Reset PinCompleting the Installation Programming the Control PanelInstalling the Point Chart Label Testing the SystemService Walk Test Service Walk Test ProcedureD9412GV3/D7412GV3 Operation and Installation Guide Test a device Bosch Security Systems, Inc /10 F01U143070-03Text displays for 60 seconds D7412GV3 Service Walk Test Flow Chart Primary Power Terminals 1 Power SupplySecondary Power Terminals Non-Power-Limited Wiring Replacing the Battery Charging and Battery LEDs D8132 Boost Battery Backup Adding a D8132Investigate Low Battery reports immediately If Battery Charging CircuitBattery Discharge and Recharge Schedule Charging Status and Low Battery LEDsDischarge Cycle Recharge CyclePower Outputs Total Available PowerContinuous Power Output Terminals 3, 8, 24, Circuit ProtectionProgrammable Power Output Terminals 6, 7, Verification and Reset RelayA  NSC current = Alarm current Required Step Available Voltage Output at Terminals 6, 7,Telephone Connections RegistrationNotification LocationPhone LED Red Operation Monitor LED GreenDialing Format Telephone Line Monitor11 D928 Dual Phone Line Switcher DescriptionTerminals 11 to 22 Description On-Board PointsPoint Sensor Loops Point Parameters Point ParametersLoop Voltage Range Point Response Time 64 mm 1/4 Minimum distance Comm Off-Board Points Point Zonex Bus D9412GV3 Terminals and D7412GV3Off-Board Point Errors Error Condition Result Additional InformationD8125 and D9127 Popit Modules 5 D9412GV3/D7412GV3 Responses to Missing Point ConditionsConnecting the D8125 Popex to the D9412GV3 Control Panel Connecting the D8125 Popex to the D7412GV3 Control Panel Installing the D8125 Popex Module Wiring Data Expansion Loops to Popex Modules Popit Sensor LoopsPopit Module Point Assignments Program Record SheetD8128D OctoPOPIT Module Program Record Sheet Popit LabelsRequirements for Fire Initiation Applications D8128D OctoPOPIT LayoutInstallation Setting the OctoPOPIT SwitchesAddress Switches D8128D OctoPOPIT Switch Settings for D9412GV3 and D7412GV3Wiring OctoPOPITs Using the Terminal StripMounting OctoPOPITs Terminal Strip ConnectionsConnecting D8128D OctoPOPITs to the D9412GV3 Connecting D8128D OctoPOPITs to the D7412GV3 Using Molex Connectors Wiring Multiple D8128Ds Using Molex ConnectorsTesting Off-Board Points OctoPOPIT Sensor LoopsOff-Board Relays 10.1 D8129 OctoRelayD8129 OctoRelay Switch Settings Configuring the D8129 OctoRelayRelay Outputs 10.2 D811 Arm Status Relay Module Wiring ConnectionsNumber of D8128Ds Used with D8129s D811 Module Wiring to the D9412GV3 D811 Module Wiring to the D7412GV3 Keypad Address Settings Arming DevicesDescription Keypad Terminals 29 toWire Limits for Individual Devices Extra Power for More KeypadsD9412GV3 Keypad D7412GV3 Function Wire Terminal Color Keypad Connections11.3 D279A Independent Zone Control KeyswitchOperation Maintained Contact Momentary Contact Silencing the BellSDI Devices Installation12.3 D9131A Parallel Printer Interface Module 12.4 D9210B Wiegand Control Interface Module SDI Addresses 88 Network Interface Modules Address Settings Supervision Programmer and Accessory Connections Programmer ConnectorInstaller Keypad and Local Programmers Mode Programmer Access ReportsAccessory Connector Accessory connector Programming connectorFaceplates 14.1 D9412GV3 Faceplate14.2 D7412GV3 Faceplate D7412GV3 FaceplateAppendix a System Wiring Diagrams, Issue a D9412GV3 Control PanelD9412GV3 D9412GV3, SDI Devices System Wiring System Wiring D7412GV3, Power Supply Side System Wiring D7412GV3 Control PanelD7412GV3 D7412GV3, SDI Devices System Wiring Appendix B Point Address Charts Zonex 1 Point Address ChartZonex 2 Point Address Chart Zonex 2, Points 129 to 247 D9412GV3 OnlySpecifications Power SupplyD9412GV3/D7412GV3 Operation and Installation Guide Notes Bosch Security Systems, Inc
Related manuals
Manual 154 pages 49.97 Kb