D9412GV3/D7412GV3 Operation and Installation Guide Specifications
Specifications
Table 26: Specifications
|
|
|
|
|
|
|
| Voltage Input |
| Primary: | Terminals 1 | 16.5 VAC 40 VA class 2 | |
| (Power |
|
| and 2 |
|
|
| Supply) |
| Secondary: | Terminals 4 | Sealed | |
|
|
|
| and 5 | Ah). The control panel supports up to two 12.0 VDC, 7 Ah batteries using the | |
|
|
|
|
| D122 Dual Battery Harness or two D1218 (12.0 VDC, 17.2 or 18 Ah) batteries | |
|
|
|
|
| using a D122. | |
| Current |
| Control Panel: Idle 225 mA; Alarm 300 mA |
| ||
| Requirements |
| Refer to the Current Rating Chart for Standby Battery Calculations section in the D9412GV3/D7412GV3 Approved |
| ||
|
|
| Applications Compliance Guide (P/N: F01U143069) for the current draw requirements of other system components. |
| ||
| Power |
| All external connections are | |||
| Outputs* |
|
|
|
|
|
|
| Continuous | Terminals 3, | 1.4 A maximum at 12.0 VDC nominal (continuous supply) total for all devices and | ||
|
|
| ||||
|
|
| Power | 24, and 32 | outputs supplied at Terminals 3, 24, and 32 and at the accessory and | |
|
|
| Outputs |
| programming connectors. | |
|
|
| Alarm Power | Terminals 6 | 2.0 A maximum at 12.0 VDC nominal output. Output can be steady or one of | |
|
|
| Output | and 7 | three pulsed patterns depending on programming. Refer to Relays in the | |
|
|
|
|
| D9412GV3/D7412GV3 Program Entry Guide (P/N: F01U170807). | |
|
|
| Switched Aux | Terminal 8 | 1.4 A maximum at 12.0 VDC nominal output. Continuous output is interrupted by | |
|
|
| Power |
| Sensor Reset or alarm verification depending on programming. Refer to Relays | |
|
|
|
|
| in the D9412GV3/D7412GV3 Program Entry Guide (P/N: F01U170807). | |
|
|
| Fire and | To comply with | UL 985 and 864 listing standards for fire alarm systems (effective March 1, 1989), | |
|
|
| Fire/Burglary | the total combined continuous and alarm current draw for the system during alarm conditions must | ||
|
|
| Systems | be limited to 1.4 A provided by the primary power supply (rectified AC). If current draw for the | ||
|
|
|
| system exceeds 1.4 A, remove connected devices until the current draw falls below 1.4 A. Then, | ||
|
|
|
| connect the removed devices to a D8132 Battery Charger Module or to an external power supply | ||
|
|
|
| (refer to Figure 29 on page 58). |
*For UL 864 applications, refer to Table 3 on page 11 for compatible devices.
Minimum
Operating
Voltage
SDI Bus
Telephone Connections
Battery
Discharge/
Recharge
Schedule
Environmental
Arming
Stations
Point
Thresholds
Compatible Enclosures
| 10.2 VDC |
|
|
|
|
| |
| SDI Bus A (+): |
| 9 VDC 4572 m (15000 ft) maximum |
| |||
|
|
| |||||
| SDI Bus B |
| 9 VDC 4572 m (15000 ft) maximum |
| |||
| Connection: |
| RJ31X or RJ38X jack can connect the control panels. |
| |||
| Two Telco |
| Bosch Security Systems, Inc. D928 Dual Phone Line Module required for two phone line service. |
| |||
| lines: |
| Supervision supplied by the control panel. |
| |||
| Discharge |
| 13.9 VDC |
| Charging float level. |
| |
| Cycle |
| 13.8 VDC |
| Charging status LED on. |
| |
|
|
|
| 12.1 VDC |
| Low Battery and AC Fail Reports if programmed. Low Battery LED on. |
|
|
|
|
| 10.2 VDC |
| Minimum operational voltage |
|
|
|
|
| 10.0 VDC |
| Battery load shed (processing functions continue if AC is present). |
|
| Recharge |
| AC ON |
| Load shed relay resets, battery charging begins, Battery Trouble and AC |
| |
| Cycle |
|
|
| Restoral Reports sent. |
| |
|
|
|
| 13.7 VDC |
| Battery Restoral Report sent, Low Battery LED off. |
|
|
|
|
| 13.9 VDC |
| Charging status LED off, battery float charged. |
|
| Temperature: |
|
| 0°C to +50°C (+32°F to +122°F) |
| ||
|
|
|
|
|
|
|
|
| Relative |
|
| Maximum 93% |
| ||
| Humidity: |
|
|
|
|
|
|
| D720/D720B Keypads, D1255/D1255B/D1255RB Keypads, D1256/D1256RB Fire Keypads; D1257/D1257RB Fire |
| |||||
| Alarm Annunciators; D1260/D1260B Keypads; Keyswitch |
| |||||
|
|
| Open | Greater than 3.7 VDC, but less than 5.0 VDC. |
| ||
| Points 1 to 8 |
|
| Normal | Greater than 2.0 VDC, but less than 3.0 VDC. |
| |
|
|
|
| Short | Greater than 0.0 VDC, but less than 1.3 VDC. |
|
D8103 Universal Enclosure, D8109 Fire Enclosure, D8108A Attack Resistant Enclosure,
Bosch Security Systems, Inc. 10/10 | 74 |