Barnett Engineering ARU CV2 instruction manual Dial, Wait

Page 29

Configuration using the PC

3-15

Only Digital inputs can be used for this purpose. The selection shown in the list box is restricted to inputs that are set to digital in the Hardware section.

To use this feature, the input must be selected in the Points section and enabled.

Default Special Function Input: NONE.

3.5.4 Directories

The Directories contain the sequences of actions that will occur when an alarm is activated in a group. Instructions for dialing, speaking, inserting delays and signaling are placed in the directory in the order in which they are to be performed. Each of the six directories can contain unique operational sequences. The directory summary displays the sequence of events in a line-by-line format. A line represents one complete action, usually a cellular call. Edit the highlighted line by pressing Enter, double-clicking on the line, or selecting the Edit Line command from the menubar in the summary window. Lines can also be removed or inserted.

The editor dialog box displays two columns on the left, one for the Command entry and the other for the Value entry, if any. Buttons for each type of command are arranged on the right. Commands are entered when you click on the buttons on the right side of the dialog box. The command appears at the location currently selected -- shown by an active option button. If the command has an associated Value such as a telephone number or waiting interval, then the value field to the right of the command will be accessible for data entry. Commands can be added at the end of the list or inserted into the middle of the list.

The commands and their functions are:

Dial

The Dial command is the first command entry. Associated with the Dial command is a telephone number that is entered in the Value field; this is the number that will be called when an alarm condition is detected. The maximum length of the telephone number is 39 digits. The special character ‘!’ can be inserted anywhere in the telephone number to create a two second delay in the dialing sequence.

When this command is encountered in the directory, the Cv2 initiates a callout on the cellular network and then maintains the call until the last command in the line is executed.

Dial can only appear as the first entry in the list.

Default Dial value: 0000

Wait

The Wait command is used to insert delays into the sequence. Associated with the Wait command is the time delay in seconds; range of the delay is from 0 to 255 seconds.

Wait can be a single entry on a line but if it is entered in a line with other commands it must be preceded by a Dial command.

Default Wait value: 0000

B1272M001

BARNETT ENGINEERING LTD.

ProTalk Cv2

Image 29
Contents 1272M001 3UR7DONContents Cv2 Capabilities What constitutes an alarm?Way in which the Cv2 processes alarms is shown in Figure How are alarms processed?What actions should occur when an alarm is detected? How do you want to respond to an alarm call? Sending remote control commands What if an alarm is not acknowledged?What do you want the Cv2 to do when you call it? Troubleshooting IndicatorsAre the inputs connected properly? Packaged model Antenna requirementsMounting Stand-alone model Ground closure alarm signalInput port connections Analog input 2 +12 volt alarm signal3 +5 volt alarm signal Output port connections Configuration programming connectionStand-alone Cv2 Starting the configuration program Installing the programDesktop and how to access programming functions PC requirementsHardware File OperationsGeneral GroupsDirectories Configuring the Cv2Programming Hardware sectionTotalizer Input Watchdog InputInterval Input Points section On/Off OutputTimed Output Point Name Common Settings for Points Port SelectionUsing Group Alarm State EnabledDigital and Watchdog Points Dtmf TagAnalog Point Clear CodeUnits Decimal Values CalibrateBinary Values Dtmf On Code HysteresisOn/Off Output Point Group section Dtmf Off CodeTimed Output Point Enable Auto Ack Enable This GroupGroup Name Acknowledge CodeTimers Enable Ack RequestShort Timer Long TimerNew Alarm Alarm ActiveSpecial Function Outputs Acknowledge ReceivedWait DialAlert Auto AckVoice AnswerAccess Code SignalDelete Site NameCall Progress Shift Change CodeTemporary Acknowledge Time Vocabulary Configuration DataVoice Messages Commands SetupAccess Dial Cv2 Site ID is Ajax Compressor Station Cv2 Electrical on or Electrical OFF Telset Programming Summary Exit Record Points Query NAM Programmable Features SpecificationsOptions TelephoneWarranty